// -----------------------------Ysystem and Yprim-----------------//
// -----------------------------------------------------------------------//
Clear
set datapath=C:\Users\paula\Desktop\OPENDSS_OCHOA_CLASS\MATLAB_APPLICATION\
// -----------------------------------------------------------------------//
// Circuit
// -----------------------------------------------------------------------//
New Circuit.TheveninEquivalent basekv=115 bus1=100
// -----------------------------------------------------------------------//
// Transformer 1
// -----------------------------------------------------------------------//
New Transformer.t1 phases=3 windings=2 xhl=5
~ wdg=1 bus=100 conn=delta kv=115 kva=5000
~ wdg=2 bus=200 conn=wye kv=4.16 kva=5000
// -----------------------------------------------------------------------//
// Line
// -----------------------------------------------------------------------//
//New Line.Ln phases=2 bus1=200.1.2 bus2=300.1.2 length=0.3 units=km
//~ rmatrix = (0.8261 | 0.1284 0.8226)
//~ xmatrix = (0.8370 | 0.2853 0.8431)
//~ cmatrix = (7.7626 | -1.4833 7.6902)
// -----------------------------------------------------------------------//
// Transformer 2
// -----------------------------------------------------------------------//
//New Transformer.t2 phases=1 windings=3 xhl=3.75 xht=3.75 xlt=2.5
//~ wdg=1 bus=300.1.2 conn=delta kv=4.16 kva=500
//~ wdg=2 bus=400.1.0 conn=wye kv=0.11 kva=500
//~ wdg=3 bus=400.0.1 conn=wye kv=0.11 kva=500
// -----------------------------------------------------------------------//
// Load 1
// -----------------------------------------------------------------------//
New Load.L1 phases=3 conn=wye bus1=200 kv=4.16 kw=160 kvar=110
// -----------------------------------------------------------------------//
// Load 2
// -----------------------------------------------------------------------//
//New Load.L2 phases=1 bus1=400.1.2 kv=0.22 kw=50 kvar=10
// -----------------------------------------------------------------------//
// Load 3
// -----------------------------------------------------------------------//
//New Load.L3 phases=1 bus1=400.1 kv=0.11 kw=40 kvar=15
set voltagebases=[115 4.16]
calc voltagebases
Solve