Set up Home Assistant with the P1P2MQTT bridge

This page describes how to configure your P1P2MQTT bridge and Home Assistant (HA).

Text in italics applies only to Daikin Altherma/E-series models.

Firmware update from earlier version

As a new user you may skip this section.

You can delete old MQTT topics and rebuild the new ones with the MQTT_Delete_Own_Rebuild button in HC_Bridge; this button may be unavailable until the bridge is running for 2 minutes. Deleting/rebuilding may take ~5 minutes. If upgrading from v0.9.44 or older, use MQTT_All_Delete_Rebuild because of the different topic structure, but be aware that this also deletes all homeassistant-config messages from other devices (if any) on the same MQTT server.

The EEPROM data in the ESP includes MQTT server credentials and should survive a firmware update, but if that fails (especially for rc candidates shared by mail), you may encounter a bridge which connects to WiFi but not to MQTT. In that case you can either -telnet to the bridge, and use the commands P7 IPv4-MQTT-server, and if necessary also P8 MQTT-port-nr, P9 MQTT-username and P10 MQTT-password, or -double-tap the reset-button until the blue LED lights up, connect to the AP with SSID P1P2MQTT-2x and password P1P2P3P4, and enter WiFi and MQTT server credentials.

Set up MQTT server

An MQTT server is required. If you do not have one yet, you can set it up in HA under Settings/Add-ons/ADD-ON STORE. Find Mosquitto broker, INSTALL it, enable the Watchdog, and click START.

Under Settings/People, click blue button (lower right corner) ADD PERSON, enter user name P1P2, switch Allow person to login on, click CREATE, set password to P1P2 (or preferably something better), and click CREATE.

Power off Daikin system

For safety, remove power from your system (likely from the outdoor unit) to remove power from the P1/P2 interface. The display of your room thermostat (if you have any) should be off.

Connect P1P2MQTT bridge to P1/P2 wires

The P1P2MQTT bridge can be connected in parallel to your room thermostat, either near your thermostat or near your indoor unit. If you have a monoblock, the P1/P2 connection may be outside. It is recommended to use a P1/P2 cable such that the P1P2MQTT bridge can be in-house.

Power on Daikin system

A WiFi Access Point with SSID P1P2MQTT (or P1P2MQTT-2x after a double-reset) should become available.

Provide WiFi and MQTT server credentials

Connect to the AP P1P2MQTT or P1P2MQTT-2x. Default password for P1P2MQTT is P1P2P3P4 but you can change it later. Password for P1P2MTT-2x is P1P2P3P4 but cannot be changed. After connecting, enter WiFi credentials, and do not forget to also provide MQTT server credentials at the same time.

If you use the MQTT server from HA and do not know its IPv4 address, it can be found under Settings/System/Network/Configure network interfaces/3-dots/IP-information. Default port is 1883, MQTT user is P1P2 and MQTT password is what you entered yourself.

Add MQTT integration

In HA, under Settings/Devices & Services, click (lower right) blue button ADD INTEGRATION, search for MQTT, select MQTT, enter MQTT server details, user and password, and SUBMIT.

Wait for auto-discovery

HA will start to recognize several controls and entities under various devices called HC_*, visible under Settings/Devices & Services/MQTT/devices. Give it some time to find all controls and entities.

Some entities become visible only when the bridge is operating in auxiliary control mode and in counter request mode. These modes can be switched on with the Control_Function switch and the Counter_Request_Function switch in the HC_Bridge device. After switching on, wait at least 10 minutes for all entities to be recognized in HA, then proceed to add the following subdevices to your HA dashboards.

Device (E-series) # Function # Controls
HC_Bridge 4 Settings and status of P1P2MQTT bridge 5 Control_Function
Counter_Request_Function
Restart_*
EEPROM_* MQTT_Rebuild
HC_Sensors 16 Temperature, flow, water pressure (*) n/a
HC_Room 12 Room temperature setpoints 1 Room_Heating
Room_Cooling (*)
HC_LWT 15 Leaving Water Temperature setpoints main zone 2 LWT_ABS_Heating
LWT_ABS_Cooling
LWT_Deviation_Heating
LWT_Deviation_Cooling (*)
HC_LWT2 17 Leaving Water Temperature setpoints add zone 3 LWT_ABS_Heating
LWT_ABS_Cooling
LWT_Deviation_Heating
LWT_Deviation_Cooling (*)
HC_Prices 11 Electricity/gas price 10 Gas price
HC_Power 13 Power consumption (requires external meter) and production n/a
HC_Mode 14 Operating modes 6 Altherma_ON
Daikin_Defrost_Request
Daikin_Restart_Careful
Heating/Cooling/Auto
Abs/WD/Abs+prog/WD+prog
HC_FieldSettings n/a Field settings; changing these requires a system restart 7 Nr_Of_Zones
Overshoot
RT/LWT
RT_Modulation
RT_Modulation_Max
HC_DHW (D) DHW settings and info (D) DHC_Setpoint
DHW_heat/off
DHW_Boost
HC_Quiet n/a Quiet/silent mode setting 8 Quiet_Level
Quiet_Level_When_On
Auto/On/Always-off
HC_COP 9 COP calculations
HC_Meters (S) Hours/kWh counters (C2 mode recommended to update counters)
HC_Unknown (S) Some unknown entities
HC_Setup (S) Single control entity for HA setup (C) HA_Setup
Factory_Reset_*
MQTT_Delete_

(Numbering # 1-17 is a suggestion how to order devices on a single dashboard in a 3-column configuration for PC use; for HA app another order may be more appropriate)

(D) Suggest to use separate DHW dashboard
(S) Suggest to use separate dashboard
(C) Can be controlled from MQTT integration, no need to add to dashboard
(*) Depending on model and operation mode, more or fewer controls may be visible. Some systems do not report flow or water pressure.

Device (F-series) Function Controls
HC_Bridge Settings and status of P1P2MQTT bridge Control_Function
Restart_*
EEPROM_*``Factory_reset_*
MQTT_*
HC_Sensors Temperature
HC_Thermistors Temperature
HC_Setpoints Temperature setpoints, fan speed Setpoint_Cooling
Setpoint_Heating
(more tbd)
HC_Mode Operating modes Power (on/off)
HC_Unknown Some unknown entities
HC_Filter Filter status

(*) Depending on model and operation mode, more or fewer controls may be visible.

Set up HA dashboards

After waiting for the entities to be recognized, the HC_* devices can now be added to your HA dashboards. You can skip adding HC_Setup.

Finish set-up

Some controls may not be useful for your system (additional zone, cooling), these can now be deleted by editing your dashboards

Once all dashboards are set up, it is recommended to switch HA_setup (in HC_Setup) off to improve the HA control interface, and to make this change permanent with the EEPROM_ESP_Save_Changes button in HC_Bridge.

Ready!

You should now be ready to monitor your system, and, if you switch(ed) Control_Function on, to control your system.

To limit the number of write instructions to your Daikin, a Write_Budget is available; if run-out, you can increase it under HC_Bridge. The budget is increased by 1 every Write_Budget_Period minutes.

The controls for room temperature are only visible if the system operates in RT mode. If the system is switched to RT mode later, this may not become visible on the dashboard until you add the newly discovered controls.

Changes made under HC_Fieldsettings will require a Daikin system restart. The Daikin_Restart_Careful button is enabled only if the system is not heating or cooling.

Trouble-shooting

If the red LED flashes in the P1P2MQTT bridge, this signals read errors or bus collission errors. You can telnet to the P1P2MQTT bridge to find out why.

If the P1P2MQTT bridge fails to connect to WiFi, it will recreate the AP, with a SSID/password (default P1P2MQTT/P1P2P3P4, unless the password was reconfigured by you), and you can re-enter all credentials.

If the P1P2MQTT bridge connects to WiFi but not to the MQTT server, you can double-reset the bridge to recreate the original AP (always with default SSID/password P1P2MQTT-2x/P1P2P3P4) and you can re-enter WiFi and MQTT credentials.

If the P1P2MQTT bridge cannot be put in Control_Function (if the switch bounces back), you can telnet to the P1P2MQTT bridge to find out if there are any informational or error messages.

If some controls or entities appear to be missing, you can switch HA_Setup on again (no need to save this) and press MQTT_Rebuild (under HC_Bridge) to repeat the MQTT configuration topics for Home Assistant, and re-add devices to your dashboard.

If you want to delete old MQTT topics (after an update from an earlier firmware, or if you change the topic structure, device name or bridge name yourself), you can press MQTT_Delete_Rebuild (under HC_Bridge) to delete all MQTT topics from all bridges and recreate new ones.

Control and entity overview (Daikin Altherma / E-series)

HC_Setup
Function Description
HA_Setup Enables proper initial set-up of HA dashboards (or otherwise controls may be incomplete), enables button for locking production/consumption counters for COP_Before_Bridge/COP_After_Bridge calculations, and enables factory_reset button. After setup, strongly recommended to switch to off. No need to add to any dashboard.
HC_Bridge
Function Description
Control_Function Determines whether P1P2MQTT bridge operates in auxiliary control mode. Not needed for monitoring, but required for controlling your system
Counter_Request_Function Determines whether P1P2MQTT bridge will request kWh/hour/start counters once every minute. Violates P1/P2 timing protocol, but works on most systems
EEPROM_ESP_Save_Changes Saves changes made (offsets, Cons_Prod_Counters) to ESP EEPROM
EEPROM_ESP_Set_Cons_Prod_Counters If not already done automatically, pressing this button will store the current consumption/production counters for calculation of COP_Before_Bridge and COP_After_Bridge enabling you to monitor improvements of your system's average COP; to save changes, also press EEPROM_ESP_Save_Changes. Button is disabled if HA_Setup is switched off.
EEPROM_ESP_Undo_Changes Undo changes made to EEPROM (not possible after saving)
Factory_Reset_ESP_After_Restart Use with care! This will schedule a factory reset on the next ESP restart. It will then reset all ESP-stored values to their original value, including device name, bridge name, AP, and more, but (as of v0.9.52:) excluding MQTT server credentials. Can be cancelled with Factory_Reset_ESP_Cancel but cannot be undone after ESP restart. Button is disabled if HA_Setup is switched off.
Factory_Reset_ESP_Cancel Unschedule any scheduled factory reset
MQTT_Rebuild Retransmits all Home Assistant configuration messages; can be used if HA missed one or more of these messages.
MQTT_Delete_Rebuild Idem, but first deletes all Home Assistant configuration messages from (any of) your P1P2MQTT bridge(s), followed by a rebuild of this bridge (but not any others if you have multiple). Useful after a firmware upgrade to delete old entities. Button is disabled for ca 2 minutes after ESP restart of after a MQTT reconnect.
R1Toffset_Mid Correction value for temperature sensor R1T (after heat exchanger, before gas boiler or backup heater). If your system is not heating or cooling, but water flow is high, R1T and R2T and R4T should give the same temperature reading. Many users report temperature differences, leading to wrong heat production and wrong COP calculations. Tune these values such that Power_Heatpump and Power_Gasboiler (/BUH) are minimal when flow is high (during the start-up phase of your system)
R2Toffset_LWT Correction value for temperature sensor R2T (leaving water temperature)
R4Toffset_RWT Correction value for temperature sensor R4T (return water temperature)
Restart_P1P2Monitor_ATmega Restarts ATmega. Should not be needed, but can be used to quickly increase write budget
Restart_P1P2MQTT_ESP Restarts ESP. Does factory_reset if scheduled. Should not be needed, but can be attempted in case of communication or other problems.
RToffset_Room Can be used to offset reported room temperature settings, has no other effects
Write_Budget Write budget limits the amount of control operations to reduce memory wear; can be increased manually if needed
Write_Budget_Period Write budget is regularly increased, by default once every hour. Period is in minutes. For Daikin E-systems, it is likely that flash wear levling is implemented to it is likely safe to reduce the period
Error_Budget Indicates how many read errors are accepted before switching Control_Function and Counter_Request_Function off. Should be 20, or a bit lower after a system restart. Errors should not be present, except for a few messages when the Daikin system restarts.
ESP_EEPROM_Saved Indicates whether all changes made have been saved to EEPROM
ESP_Ectory_Reset_Scheduled Indicates if a factory reset is scheduled for the next ESP reset
ESP_Throttling Indicates that the ESP is throttling data - messages can be missing or delayed. Happens after an ESP restart or after a MQTT disconnect/reconnect action
ESP_Waiting_For_Counters_D13 Indicates that the ESP is waiting for consumption/production counters to store these counters for COP_Before_Bridge/COP_After_Bridge calculation. Counters will be read when (1) Counter_Request_Function is switched on, (2) Daikin system is restarted, (3) room thermostat requests counters, or (4) EEPROM_ESP_Set_Cons_Prod_Counters is pressed.
V_Interfce Reports voltage on P1/P2 interface for bus-powered devices. For bridges powered from a DC power supply, reports DC voltage.
Writes_Refused_Budget Indicates how many writes have been refused due to missing write budget; should be 0
Writes_Refused_Busy Indicates how many writes have been refused due to lack of buffering; should be 0
HC_Mode
Function Description
Altherma_On Switches Daikin on/off
Daikin_Defrost_Request Requests Daikin to defrost; Daikin may schedule a defrost depending on environmental conditions
Heating_Cooling_Auto Switches system between Heating, Cooling, and Auto
Program_WD_Abs Switches system between Abs (absolute LWT), WD (weather-dependent LWT), Abs+prog (+clock program), or WD+prog
BUH_2 Shows status of 2nd backup heater
Circulation_Pump Shows status of circulation pump for LWT
Climate_Cooling Shows whether climate for cooling is active
Climate_HC_Auto Shows whether climate will change automatically between heating and cooling
Climate_Heating Shows whether climate for heating is active
Compressor Shows whether compressor is on
Date_Time_Daikin Reports Daikin internal time
Defrost_Active Reports whether outdoor unit is defrosting
ErrorCode1/2/Subcode Shows Daikin error report. Encoding largely unknown. If you see any error, please share codes and the error code on your room thermostat
Gasboiler_Active Shows whether gas boiler (on all-electric: backup heater) is active
Heating_Only Indicates that system has no cooling option
Preferential_Mode Indicates that preferential mode on hybrid system is actived (switch on X5M-3,4)
Valve_Zone_Add ? Indicates status of valve for additional zone
Valve_Zone_Main ? Indicates status of valve for main zone
HC_Room
Function Description
Room_Heating In RT mode, controls room temperature setpoint, on/off, and reports room temperature
Room_Cooling In RT mode, controls room temperature setpoint, on/off, and reports room temperature
Room_Heating_Setpoint Setpoint for room temperature if in heating mode
Room_Cooling_Setpoint Setpoint for room temperature if in cooling mode
Room_Setpoint Currently active setpoint for room temperature
HC_LWT
Function Description
Abs_Heating_Add or Deviation_Heating_Add In LWT/Abs mode, control for on/off and for absolute setpoint of leaving water temperature. In LWT/WD mode, controls deviation from WD setpoint. Also reports actual LWT temperature.
Abs_Cooling_Add or Deviation_Cooling_Add Idem for cooling
Abs_Heating Absolute LWT setpoint heating mode
Abs_Cooling Absolute LWT setpoint cooling mode
Deviation_Heating Deviation from WD curve if in heating mode
Deviation_Cooling Deviation from WD curve if in cooling mode
LWT_Setpoint Currently active LWT setpoint
HC_LWT2
Function Description
Same as for HC_LWT, with _Add added Idem as for HC_LWT, but for additional zone
HC_Quiet

On (some?) newer Altherma 3 R models, Quiet_Level monitors the current quiet status but controls do not work.

Function Description
Quiet_Level Switches unit to quiet level 0 (off), 1, 2, or 3 (most silent). Can be used to limit power consumption
Quiet_Level_When_On Quiet level when selected on room thermostat
Quiet_Mode Switches quiet mode on or off
HC_Prices
Function Description
Gas Can be used to modify gas price
Electricity Shows current electricity price (based on clock programs, predetermined low/mid/high prices can only be modified via field settings)
HC_FieldSettings
Function Description
Daikin_Restart_Careful Restarts Daikin. Disabled if Daikin is on. Also restarts ESP and ATmega (unless separately powered). Required to make field setting changes effective.
Number_of_Zones Indicates whether additional zone is used. Corresponds to menu A.2.1.8 or field setting [7-02].
Overshoot Maximum allowed LWT overshoot. Unfortunately cannot be changed on hybrid systems (even though max is reported to be 4, it refuses to change this value). Default value of 1 leads to cycling. Recommended to set to 4 on all-electric systems. Corresponds to field setting [9-04].
RT_LWT Switches between RT (room temperature) and LWT (leaving water temperature) mode. In RT mode, LWT control is not possible via room thermostat, but is still possible via P1P2MQTT bridge (in selected Abs or WD mode).
various entities overview of all current field settings with description and menu entry (based on hybrid model), for example:
0_0D_A47_DHW_WD_Curve_High_Amb
0_0E_A47_DHW_WD_Curve_Low_Amb
1_0A_A64_Averaging_Time
C_03_Bivalent_Activation_Temperature
HC_Power
Function Description
Consumption_BUH (not supported yet) gas consumption gas boiler or electricity consumption backup heater
Consumption_Heatpump External electricity meter input as reported via MQTT P1P2/P/meter/U/9/Electricity_Power in Watt
Production_Gasboiler Gas boiler or backup heater heat production (flow * delta-T, with offset correction on temperature sensors)
Production_Heatpump Heat pump (without backup heater) heat production (flow * delta-T, with offset correction on temperature sensors)

Note: Consumption_Heatpump is based on P1P2/P/meter/U/9/Electricity_Power which is a MQTT topic to be provided by an external electricity meter for the outside unit's compressor (so without BUH). It is required for the calculation of COP_Realtime.

HC_COP
Function Description
COP_Lifetime Average COP over lifetime of Daikin, based on Daikin reported kWh counters
COP_Before_Bridge Average COP over lifetime of Daikin until P1P2MQTT bridge locked consumtion/production counters (EEPROM_ESP_Set_Cons_Prod_Counters)
COP_Before_Bridge Average COP over lifetime of Daikin afterP1P2MQTT bridge locked consumtion/production counters
COP_Realtime Real-time COP based on Production_Heatpump/Consumption_Heatpump

Note: COP_Realtime is only calculated if Consumption_Heatpump is (regularly) provided by an external electricity meter via MQTT.

HC_Meters
Function Description
Various kWh/hours/start counters, only updated every minute if Counter_Request_Function is on, otherwise only if room thermostat asks for these counters, for example:
Electricity_Consumed_Backup_DHW
Electricity_Consumed_Backup_Heating
Electricity_Consumed_Compressor_Heating
Electricity_Consumed_Compressor_Cooling
Energy_Produced_Compressor_Cooling
Hours_Backup1_DHW
Hours_Circulation_Pump
Hours_Compressor_Heating
Starts_Compressor
Starts_Gasboiler
HC_Sensors
Function Description
Flow Water circulation flow (some systems report 0.0, making production calculation impossible)
Temperature_Outside Outside temperature for WD calculation, based on external temperature sensor or outside unit
Temperature_Outside_Unit Outside unit temperature
Temperature_R1T_HP2Gas_Water Water temperature after heat exchanger and before backup heater or gas boiler
Temperature_R2T_Leaving_Water Leaving water temperature (after backup heater or gas boiler)
Temperature_R4T_Return_Waterr Return water temperature
Temperature_Refrigerant_2 Refrigerant temperature after water/water heat exchanger
Temperature_Room Temperature reported by room thermostat
Water_Pressure Circulation water pressure (only supported by a few systems)
HC_DHW
Function Description
DHW_Setpoint Controls on/off status and DHW setpoint
DHW_Boost Controls boost status
DHW Current on/off status
DHW_Demand Domestic hot water flow sensor for hybrid gas boiler (not supported on tank systems?)
DHW_Related_Q ?
DHW_Setpoint Hot water setpoint
HC_UI

Simulates functions of the auxiliary controller

Function Description
LCD_Off Switches (simulated) LCD backlight of bridge off
LCD_On Switches (simulated) LCD backlight of bridge on (LCD backlights of main and auxiliary controller cannot be both on)
Mode_0_Normal_User Puts P1P2MQTT bridge into normal user mode
Mode_1_Advanced_User Puts P1P2MQTT bridge into advanced user mode
Mode_2_Installer Puts P1P2MQTT bridge into installer mode (if/when main controller is not in installer mode)

Control and entity overview (Daikin AC / F-series)

This section is still very much raw format and likely to contains errors; too many entities are currently reported in HA, also for further reverse engineering. Some simplification of the HA interface and further reverse engineering is required. Feedback is welcome.

HC_Setup
Function Description
HA_Setup Enables proper initial set-up of HA dashboards (or otherwise controls may be incomplete), and enables factory_reset button. After setup, strongly recommended to switch to off. No need to add to any dashboard.
HC_Bridge
Function Description
Control_Function Determines whether P1P2MQTT bridge operates in auxiliary control mode. Not needed for monitoring, but required for controlling your system
Model Allows protocol selection based on major version of Daikin unit; control works only correct configured
Model_suggestion Recommended protocol selection
EEPROM_ESP_Save_Changes Saves changes made to ESP EEPROM
EEPROM_ESP_Undo_Changes Undo changes made to EEPROM (not possible after saving)
Factory_Reset_ESP_After_Restart Use with care! This will schedule a factory reset on the next ESP restart. It will then reset all ESP-stored values to their original value, including device name, bridge name, AP and MQTT server credentials, and more. Can be cancelled with Factory_Reset_ESP_Cancel but cannot be undone after ESP restart. Button is disabled if HA_Setup is switched off.
Factory_Reset_ESP_Cancel Unschedule any scheduled factory reset
MQTT_Rebuild Retransmits all Home Assistant configuration messages; can be used if HA missed one or more of these messages.
MQTT_Delete_Rebuild Idem, but first deletes all Home Assistant configuration messages from (any of) your P1P2MQTT bridge(s), followed by a rebuild of this bridge (but not any others if you have multiple). Useful after a firmware upgrade to delete old entities.
Restart_P1P2Monitor_ATmega Restarts ATmega. Should not be needed, but can be used to quickly increase write budget
Restart_P1P2MQTT_ESP Restarts ESP. Does factory_reset if scheduled. Should not be needed, but can be attempted in case of communication or other problems.
Write_Budget Write budget limits the amount of control operations to reduce memory wear; can be increased manually if needed
Write_Budget_Period Write budget is regularly increased, by default once every hour. Period is in minutes. For Daikin E-systems, it is likely that flash wear levling is implemented to it is likely safe to reduce the period
Error_Budget Indicates how many read errors are accepted before switching Control_Function and Counter_Request_Function off. Should be 20, or a bit lower after a system restart. Errors should not be present, except for a few messages when the Daikin system restarts.
ESP_EEPROM_Saved Indicates whether all changes made have been saved to EEPROM
ESP_Ectory_Reset_Scheduled Indicates if a factory reset is scheduled for the next ESP reset
ESP_Throttling Indicates that the ESP is throttling data - messages can be missing or delayed. Happens after an ESP restart or after a MQTT disconnect/reconnect action
V_Interfce Reports voltage on P1/P2 interface for bus-powered devices. For bridges powered from a DC power supply, reports DC voltage.
Writes_Refused_Budget Indicates how many writes have been refused due to missing write budget; should be 0
Writes_Refused_Busy Indicates how many writes have been refused due to lack of buffering; should be 0
HC_Mode
Function Description
Power_Request Power request from room thermostat
Power System on/off status
Heatpump_On Heat pump status
Target_Operating_Mode Target operating mode from room thermostat to aux controller
Target_Operating_Mode_0 Target operating mode from room thermostat to indoor unit
Target_Operating_Mode_1 Target operating mode by indoor unit
Actual_Operating_Mode Actual operating mode from room thermostat to aux controller
Actual_Operating_Mode_0 Actual operating mode from room thermostat to indoor unit
Actual_Operating_Mode_1 Actual operating mode by indoor unit
System_Status Status stand-by/compressor/fan/off
Zone_Status ?
HC_Setpoints
Function Description
Setpoint_Heating Controls room temperature setpoint in heating mode
Setpoint_Cooling Controls room temperature setpoint in cooling mode
Setpoint_Temperature Current setpoint for room temperature
Setpoint_Temperature_1 Setpoint for room temperature copied back by indoor unit
Fan_Speed Setpoint for fan speed
Fan_Speed_1 Setpoint for fan speed copied back by indoor unit
Fan_Speed_Cooling Setpoint for fan speed cooling from room thermostat to aux controller
Fan_Speed_Heating Setpoint for fan speed heating from room thermostat to aux controller
HC_Sensors
Function Description
Temperature_Inside_Air_Intake Air intake temperature
Temperature_Heat_Exchanger
HC_Thermistors
Function Description
Th1 Temperature sensor, function?
Th2 Temperature sensor, function?
Th3 Temperature sensor, function?
Th4 Temperature sensor, function?
Th5 Temperature sensor, function?
Th6 Temperature sensor, function?
HC_Filter
Function Description
Filter_Related ? 000011-3
Filter_Alarm_Reset_Q ?
HC_Unknown
Function Description
Unknown_xxxxxx_xx Many individual protocol bytes, function unknown, for reverse engineering purposes
Error_Setting_1_Q Function unknown, for reverse engineering purposes