You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
--------------------------------------------------------------------------
[[60025,1],0]: A high-performance Open MPI point-to-point messaging module
was unable to find any relevant network interfaces:
Module: OpenFabrics (openib)
Host: 466e13a9963f
Another transport will be used instead, although this may result in
lower performance.
NOTE: You can disable this warning by setting the MCA parameter
btl_base_warn_component_unused to 0.
--------------------------------------------------------------------------
Simulation was run using :
* model = shannon_wang_puglisi_weber_bers_2004_model_updated
* na: no drug effect
* cal: no drug effect
* herg IC50s = 100 uM, Hills = 1, Saturation levels = 0 %.
* iks: no drug effect
* ik1: no drug effect
* ito: no drug effect
* nal: no drug effect
* max free plasma concentration = 100 uM
* min free plasma concentration = 0 uM
* number of plasma concentrations = 13
I'm seeing the following (seemingly inconsequential, as the simulation seems to complete) "warning" appearing in ApPredict https://github.com/Chaste/ApPredict/releases/tag/v2021.1 stderr in a container.
Simulation was run using :
It'd be an improvement if this wasn't appearing in the logs, so are there any suggestions for adjusting https://github.com/CardiacModelling/appredict-docker/blob/master/appredict-no-emulators/Dockerfile#L40-L47 to include that
btl_base_warn_component_unused
instruction?The text was updated successfully, but these errors were encountered: