return {
on = {
timer = {
'every minute'
--devices = {
-- 12901 -- NR: WP-Verbruik
}
},
logging = {
--level = domoticz.LOG_DEBUG, -- Uncomment to override the dzVents global logging setting and use debug
marker = "WP-COP Pana Device HM"
},
execute = function(domoticz, item)
-- devices
--local flowinstValue = domoticz.devices(12496).rawData[1] -- Flow L/min [ is % device ]
local flowinstValue = domoticz.devices(12524).rawData[1] -- Flow custom sensor ivm liters /minuut WP Flow HM
--local flowinstValue = 16 -- Flow L/min (fixed value)
local tempoutValue = domoticz.devices(12493).rawData[1] -- Temperature Heatpump out WP Uitstroom Aanvoer HM
local tempreturnValue = domoticz.devices(12494).rawData[1] -- Temperature Heatpump return WP Instroom Retour HM
local powerHeatpump = domoticz.devices(12901).rawData[1] -- HEatpump power adsorbed in watt WP Verbruik W HM
local frequentie = domoticz.devices(12526).rawData[1] -- HEatpump frquentie in Herz WP Frequentie HM
local sCOP = domoticz.devices(12963) -- Cop (dummy- custom sensor W/W ) WP COP NR DZ
-- calculation
local Watt_heat_c = math.abs(domoticz.utils.round((tempoutValue-tempreturnValue) * 4.187 * (flowinstValue/60)*1000))
local COP_calculated = math.abs(domoticz.utils.round(Watt_heat_c/powerHeatpump,2))
domoticz.log('flowinstValue ' .. flowinstValue .. ' L/min ', domoticz.LOG_DEBUG)
domoticz.log('tempoutValue ' .. tempoutValue .. ' C ', domoticz.LOG_DEBUG)
domoticz.log('tempreturnValue ' .. tempreturnValue .. ' C ', domoticz.LOG_DEBUG)
domoticz.log('powerHeatpump ' .. powerHeatpump .. ' Watt ', domoticz.LOG_DEBUG)
domoticz.log('Watt_heat_c ' .. Watt_heat_c .. ' Watt ', domoticz.LOG_DEBUG)
domoticz.log('COP_calculated ' .. COP_calculated .. ' W/W ', domoticz.LOG_DEBUG)
if tonumber(powerHeatpump) > 180 and COP_calculated < 24 and tonumber(frequentie) > 16 then -- was 11 maar geeft vertekent beeld in grafana -- DIT ERBIJ???: and tonumber(frequentie) > 80
--if tonumber(powerHeatpump) > 175 and COP_calculated < 24 and tonumber(flowinstValue) < 15 and tonumber(frequentie) > 1 then -- was 11 maar geeft vertekent beeld in grafana -- DIT ERBIJ???: and tonumber(frequentie) > 80
domoticz.openURL('http://127.0.0.1:8080/json.htm?type=command¶m=udevice&idx=12963'..'&nvalue=0&svalue='..COP_calculated) --WP COP NR DZ
domoticz.openURL('http://127.0.0.1:8080/json.htm?type=command¶m=udevice&idx=12964'..'&nvalue=0&svalue='..Watt_heat_c) --WP Vermogen direct Pana HM
else
domoticz.openURL('http://127.0.0.1:8080/json.htm?type=command¶m=udevice&idx=12963'..'&nvalue=0&svalue=0') --WP COP NR DZ
domoticz.openURL('http://127.0.0.1:8080/json.htm?type=command¶m=udevice&idx=12964'..'&nvalue=0&svalue=0') --WP Vermogen direct Pana HM
end
end
}