Notifications
You must be signed in to change notification settings - Fork 7
/
Copy pathtest_alarm_api.py
205 lines (172 loc) · 7.81 KB
/
test_alarm_api.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
from contextlib import contextmanager
import json
import logging
import os
import yaml
from time import sleep, time
import sys
import pytest
from gridappsd import GridAPPSD
from gridappsd.simulation import Simulation
from gridappsd import topics as t
LOGGER = logging.getLogger(__name__)
tapchanger_value = []
alarm_count = 0
mrid_values = {}
def compare_ids(measurement_id):
def on_message(headers, message):
global tapchanger_value
global alarm_count
global mrid_values
if "gridappsd-alarms" in headers["destination"]:
for y in message:
print(message)
if "Open" or "Close" in y['value']:
LOGGER.info(f'Alarm created {y}')
alarm_count += 1
if "gridappsd-alarms" not in headers["destination"]:
measurement_values = message["message"]["measurements"]
for x in measurement_values:
m = measurement_values[x]
if m.get("measurement_mrid") == measurement_id:
if not tapchanger_value:
LOGGER.info(f'Tap Changer value is {m.get("value")}')
tapchanger_value.append(m.get("value"))
else:
if m.get("value") != tapchanger_value[-1]:
LOGGER.info(f'Tap Changer value changed from {tapchanger_value[-1]} to {m.get("value")} {m}')
tapchanger_value.append(m.get("value"))
return on_message
def get_reg_mrids(gridappsd_obj, mrid):
query = """
PREFIX r: <http://www.w3.org/1999/02/22-rdf-syntax-ns#>
PREFIX c: <http://iec.ch/TC57/CIM100#>
SELECT ?reg_id ?trmid ?rname ?pname ?tname ?bus
WHERE {
VALUES ?fdrid {"%s"} # 123
?pxf c:Equipment.EquipmentContainer ?fdr.
?fdr c:IdentifiedObject.mRID ?fdrid.
?rtc r:type c:RatioTapChanger.
?rtc c:IdentifiedObject.name ?rname.
?rtc c:IdentifiedObject.mRID ?reg_id.
?rtc c:RatioTapChanger.TransformerEnd ?end.
?end c:TransformerEnd.Terminal ?trm.
?trm c:IdentifiedObject.mRID ?trmid.
?trm c:Terminal.ConnectivityNode ?cn.
?cn c:IdentifiedObject.name ?bus.
?end c:TransformerEnd.endNumber ?wnum.
OPTIONAL {?end c:TransformerTankEnd.phases ?phsraw.
bind(strafter(str(?phsraw),"PhaseCode.") as ?phs)}
?end c:TransformerTankEnd.TransformerTank ?tank.
?tank c:TransformerTank.PowerTransformer ?pxf.
?pxf c:IdentifiedObject.name ?pname.
?tank c:IdentifiedObject.name ?tname.
}
ORDER BY ?pname ?tname ?rname ?wnum ?bus
""" % mrid
results_reg = gridappsd_obj.query_data(query)
regulators = []
reg_name = []
results_obj = results_reg['data']
# print(results_obj)
return results_obj
@pytest.mark.parametrize("sim_config_file", [
("13-alarm.json"),
#("123-alarm.json"),
("9500-alarm.json")])
def test_alarm_output(gridappsd_client, sim_config_file):
global measurement_id
sim_config_file = os.path.join(os.path.dirname(__file__), f"simulation_config_files/{sim_config_file}")
assert os.path.exists(sim_config_file), f"File {sim_config_file} must exist to run simulation test"
gapps = gridappsd_client
# Allow proven to come up
sleep(30)
sim_complete = False
rcvd_measurement = False
def onfinishsimulation(sim):
nonlocal sim_complete
sim_complete = True
LOGGER.info('Simulation Complete')
with open(sim_config_file) as fp:
LOGGER.info('Loading config')
run_config = json.load(fp)
events = run_config["test_config"]["events"]
switch_mrid1, switch_mrid2 = [], []
# regulator_mrid1, regulator_mrid2 = [], []
for i in range(len(events)):
if "message" in events[i] and events[i]["message"]["forward_differences"][0]["attribute"] == "Switch.open":
switch_mrid1.append(events[i]["message"]["forward_differences"][0]["object"])
switch_mrid2.append(events[i]["message"]["reverse_differences"][0]["object"])
model_mrid = run_config["power_system_config"]["Line_name"]
try:
equipment_dict = {}
request1 = {
"modelId": model_mrid,
"requestType": "QUERY_OBJECT_DICT",
"resultFormat": "JSON",
"objectType": "LoadBreakSwitch"
}
request2 = {
"modelId": model_mrid,
"requestType": "QUERY_OBJECT_MEASUREMENTS",
"resultFormat": "JSON",
"objectType": "PowerTransformer"
}
response = gapps.get_response("goss.gridappsd.process.request.data.powergridmodel", request1, timeout=60)
switch_list = []
# print(response["data"])
for switch in response["data"]:
equipment_dict[switch["id"]] = switch
switch_list.append(switch['IdentifiedObject.mRID'])
# print("switch_list", switch_list)
for i in range(min(3, len(switch_list))):
print(i)
run_config["test_config"]["events"][i]["message"]["forward_differences"][0]["object"] = switch_list[i]
run_config["test_config"]["events"][i]["message"]["reverse_differences"][0]["object"] = switch_list[i]
print("testing regulator")
regulator = get_reg_mrids(gapps, model_mrid)
value = regulator['results']['bindings'][0]['reg_id']['value']
terminal_id = regulator['results']['bindings'][0]['trmid']['value']
print("value", value, terminal_id)
for i in range(len(events)):
if "message" in events[i] and events[i]["message"]["forward_differences"][0]["attribute"] == "TapChanger.step":
run_config["test_config"]["events"][i]["message"]["forward_differences"][0]["object"] = value
run_config["test_config"]["events"][i]["message"]["reverse_differences"][0]["object"] = value
if "inputOutageList" in events[i]:
run_config["test_config"]["events"][i]["inputOutageList"][0]["objectMRID"] = value
response2 = gapps.get_response("goss.gridappsd.process.request.data.powergridmodel", request2, timeout=60)
for reg in response2["data"]:
if reg['trmid'] == terminal_id:
measurement_id = reg['measid']
print(measurement_id, terminal_id)
except Exception as e:
message_str = "An error occurred while trying to translate the message received" + str(e)
LOGGER.info('Starting the simulation')
LOGGER.info(f'Simulation start time {run_config["simulation_config"]["start_time"]}')
sim = Simulation(gapps, run_config)
# print(sim._run_config)
sim.start_simulation(timeout=300)
# regulators = sim.simulation_id, gapps, regulator
LOGGER.info('sim.add_oncomplete_callback')
sim.add_oncomplete_callback(onfinishsimulation)
LOGGER.info("Querying for alarm topic")
alarms_topic = t.service_output_topic('gridappsd-alarms', sim.simulation_id)
log_topic = t.simulation_output_topic(sim.simulation_id)
# print(gapps.subscribe(log_topic, compare_ids(measurement_id)))
gapps.subscribe(alarms_topic, compare_ids(measurement_id))
gapps.subscribe(log_topic, compare_ids(measurement_id))
while not sim_complete:
LOGGER.info('Sleeping')
sleep(30)
def test_tap_changer():
global tapchanger_value
# commoutage prevents recording of last tap_changer change
assert 10 in tapchanger_value, f"Expected tap changer values [4, 10] received {tapchanger_value}"
def test_comm_outage():
global tapchanger_value
# commoutage prevents recording of last tap_changer change
assert 10 in tapchanger_value, f"Comm outage should prevent last tap change value from being recorded. " \
f"Expected values [4, 10] received {tapchanger_value} "
def test_alarm_count():
global alarm_count
assert alarm_count > 2, f"Expecting 3 alarms received {alarm_count}"