Error Codes

Code Text Description Next steps
HORST-1 Internal error! An internal error occurred and the daemon has been stopped Examine error message, fix problem if possible and restart horst
HORST-2 Fatal C++ error! An unhandled exception was thrown and the daemon has been stopped Examine error message, fix problem if possible and restart horst
HORST-3 function() failed to parse parameters Parameters to this function could not be read from D-Bus, call is ignored Fix D-Bus call to provide the correct parameters, make sure D-Bus works correctly, retry sending call
HORST-4 Failed to connect to bus Daemon was not able to connect to D-Bus Make sure D-Bus is available and restart daemon
HORST-5 Failed to acquire service name Daemon was not able to acquire his service name on D-Bus Make sure horst is only running once, there is no other service with the same D-Bus service name and restart daemon
HORST-6 Failed to add xyz match Daemon was not able to register for named signal and will not receive updates for it Make sure D-Bus is working properly and restart daemon
HORST-7 Failed to install the horst sdbus object Daemon was not able to fully initialize his D-Bus functionality Make sure D-Bus is working and restart daemon
HORST-8 Failed to check LEOP status The check_leop.sh script returned something different than 0 or 1 Check script and restart daemon
HORST-9 Failed to listen on DBus A connection to DBus could not be established Make sure DBus is available and restart daemon
HORST-10 Failed to listen on S3TP A connection to S3TP could not be established Make sure S3TP is available. Horst will automatically retry to connect regularly

Configuration File

There is no configuration file. All available configuration is done using command line parameters.

Commandline Parameters

All parameters have abbreviations with only their first character.

Parameter Default value Value
--battery 30 Battery threshold. If battery level fall below, we will go into safemode
--scripts ./scripts/ Path to scripts directory
--port 99 Listen port for S3TP
--socket /run/s3tp.socket Socket path for S3TP
--manual false Start HORST in manual mode
--help - Print short help

D-Bus interface

Horst has a D-Bus interface and listens on the following interface name.

Name Value
Name moveii.horst
Path /moveii/horst
Interface moveii.horst

Methods

Method Description
exec(s) Run given shell command
setSafemode(s) Toggle safemode on/off (False=off, True=on)
setManeuvermode(s) Toggle maneuvermode on/off (False=off, True=on)
setManualmode(s) Toggle manualmode on/off (False=off, True=on)
getBeaconData() Get beacon data of daemon
checkDaemon() Get status of beacon (always 0)
checkHardware() Get hardware status of beacon (always 0)
getVersion() Get version of daemon

Signals

Horst is listening for the following signals. All of them will update the current state table accordingly.

Signal Description
thmStateChange Update thm state
epsChargeStateChange Update battery state
leopStateChange Update leop state
payloadConditionsFullfilled Update payload state
payloadMeasurementDone Update payload state
adcsStateChange Update adcs pointing state

S3TP Interface

You can interact with HORST over S3TP. The default socket path and S3TP port number can be changed per command line parameters as documented above.

Over the S3TP interface, arbitrary shell commands can be executed on the satellite. The returned value (string) will show success or failure of the command execution, the stdout and stderr output of the executing command will be transfered back to ground over S3TP.

Please keep in mind that you might want to discard most of the output by e.g. redirecting it to /dev/null to save download capacity.

The easiest way to run remote commands is to use the remoteexec tool that can be found in /test/s3tp/. Just give your command as parameter and it will connect to HORST over s3tp, run your command and show the results.

The protocol to communicate with HORST over S3TP is specified as follows:

  1. S3TP connection is established as normal
  2. Ground starts to send a command by sending its length as unsigned 64bit integer
  3. Ground sends the command itself
  4. As soon as HORST has received the expected number of bytes it will return an "ack" string to notify that it has successfully received the command.
  5. HORST spawns a shell process with the given command
  6. HORST returns stdout and stderr of the process over s3tp. Always first the number of bytes is send, afterwards the char array itself.
  7. On exit of the process HORST returns the exit code as "[exit] 123" where 123 is replaced by the actual return code

Every command may not be longer than 4096 bytes in total (hardcoded buffer size for incoming data over S3TP).

E.g. a valid command would be:

./remoteexec ls -l