AD-SWIO 2 Click is a quad-channel software configurable input/output solution based on AD74413R, for building and process control application. The AD74413R is a quad-channel software configurable input/output solution for building and process control applications. The device provides a fully integrated single chip solution for input and output operation. The AD-SWIO 2 Click contains four 13-bit DACs, one per chanal, and 16-bit Σ-∆ ADC.
- Author : MikroE Team
- Date : jun 2020.
- Type : SPI type
We provide a library for the AdSwio2 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.
Package can be downloaded/installed directly form compilers IDE(recommended way), or downloaded from our LibStock, or found on mikroE github account.
This library contains API for AdSwio2 Click driver.
adswio2_cfg_setup
Config Object Initialization function.
void adswio2_cfg_setup ( adswio2_cfg_t *cfg );
adswio2_init
Initialization function.
ADSWIO2_RETVAL adswio2_init ( adswio2_t *ctx, adswio2_cfg_t *cfg );
adswio2_default_cfg
Click Default Configuration function.
void adswio2_default_cfg ( adswio2_t *ctx );
adswio2_get_conv_results
This function allows user to get the converted results of the selected channel.
adswio2_err_t adswio2_get_conv_results ( adswio2_t *ctx, uint8_t channel, uint16_t *data_out );
adswio2_status_pin_ready
This function checks the status of the ready pin.
uint8_t adswio2_status_pin_ready ( adswio2_t *ctx );
This Click is a quad-channel software configurable input/output solution for building and process control application. The AD-SWIO 2 Click contains four 13-bit DACs, one per chanal, and 16-bit Σ-∆ ADC. These options give a lot of flexibility in choosing functionality for analog output, analog input, digital input, resistance temperature detector (RTD), and thermocouple measurements integrated into a single chip solution with a serial peripheral interface (SPI).
The demo application is composed of two sections :
Performs a hardware reset of the Click board and executes a default configuration that enables channel A and sets it to measure voltage input in the range from 0V to 10V, with 4800 SPS.
void application_init ( void )
{
log_cfg_t log_cfg;
adswio2_cfg_t cfg;
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
// Click initialization.
adswio2_cfg_setup( &cfg );
ADSWIO2_MAP_MIKROBUS( cfg, MIKROBUS_1 );
adswio2_init( &adswio2, &cfg );
Delay_ms ( 100 );
adswio2_default_cfg( &adswio2 );
Delay_ms ( 1000 );
adswio2_rdy = DUMMY;
adswio2_ch_a = DUMMY;
adswio2_res = DUMMY;
adswio2_err = ADSWIO2_ERR_STATUS_OK;
log_printf( &logger, " AD-SWIO 2 Click initialization done \r\n");
log_printf( &logger, "************************************\r\n");
}
Waits for the data ready and then reads the results of ADC conversion from channel A and if response is ok, then prints the results on the uart console.
void application_task ( void )
{
timeout = 0;
do
{
Delay_1ms( );
timeout++;
adswio2_rdy = adswio2_status_pin_ready( &adswio2 );
if ( timeout > 3000 )
{
timeout = 0;
log_printf( &logger, " Reinitializing...");
adswio2_default_cfg( &adswio2 );
log_printf( &logger, "Done\r\n");
}
}
while ( adswio2_rdy != 0 );
adswio2_err = adswio2_get_conv_results( &adswio2, ADSWIO2_SETUP_CONV_EN_CHA, &adswio2_ch_a );
if ( adswio2_err == ADSWIO2_ERR_STATUS_OK )
{
adswio2_res = adswio2_ch_a;
adswio2_res /= ADSWIO2_RANGE_RESOLUTION;
adswio2_res *= ADSWIO2_RANGE_VOLT_MV;
adswio2_ch_a = adswio2_res;
log_printf( &logger, " Voltage from channel A: %d mV\r\n", adswio2_ch_a );
log_printf( &logger, "-----------------------------------\r\n\r\n" );
Delay_ms ( 200 );
}
}
The full application code, and ready to use projects can be installed directly form compilers IDE(recommneded) or found on LibStock page or mikroE GitHub accaunt.
Other mikroE Libraries used in the example:
- MikroSDK.Board
- MikroSDK.Log
- Click.AdSwio2
Additional notes and informations
Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. The terminal available in all Mikroelektronika compilers, or any other terminal application of your choice, can be used to read the message.