Air Flow Click

Air Flow Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.


Click Library

  • Author : Luka Filipovic
  • Date : May 2021.
  • Type : I2C/SPI type

Software Support

Example Description

This example showcases ability for device to read differential pressure, atmospheric pressure and ambient temperature.

Example Libraries

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.AirFlow

Example Key Functions

  • airflow_cfg_setup Config Object Initialization function.
void airflow_cfg_setup ( airflow_cfg_t *cfg );
  • airflow_init Initialization function.
err_t airflow_init ( airflow_t *ctx, airflow_cfg_t *cfg );
  • airflow_default_cfg Click Default Configuration function.
err_t airflow_default_cfg ( airflow_t *ctx );
  • airflow_reset_device Reset device.
void airflow_reset_device ( airflow_t *ctx )
  • airflow_get_differential_pressure Reads differential pressure.
err_t airflow_get_differential_pressure ( airflow_t *ctx, float *pressure )
  • airflow_get_atmospheric_pressure Reads atmospheric pressure and temperature.
err_t airflow_get_atmospheric_pressure ( airflow_t *ctx, float *pressure, float *temperature );

Application Init

Initialize host communication modules (UART, I2C/SPI). Read electric signature data from device and logs it to terminal.

void application_init ( void ) 
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    airflow_cfg_t airflow_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    Delay_ms ( 100 );
    log_info( &logger, " Application Init " );

    // Click initialization.
    airflow_cfg_setup( &airflow_cfg );
    AIRFLOW_MAP_MIKROBUS( airflow_cfg, MIKROBUS_1 );
    err_t init_flag  = airflow_init( &airflow, &airflow_cfg );
    if ( ( init_flag == I2C_MASTER_ERROR ) || ( init_flag == SPI_MASTER_ERROR ) ) 
    {
        log_error( &logger, " Application Init Error. " );
        log_info( &logger, " Please, run program again... " );

        for ( ; ; );
    }
    
    airflow_reset_device( &airflow );
    
    if ( airflow_default_cfg ( &airflow ) < 0 )
    {
        log_error( &logger, " Read" );
        log_info( &logger, " Please, run program again... " );
        for ( ; ; );
    }
    else
    {
        log_printf( &logger, "Firmware version: %d.%d\r\n", ( int16_t )airflow.major_fw_ver, ( int16_t )airflow.minor_fw_ver );
        //part number
        log_printf( &logger, "Part number: " );
        for ( uint8_t pn = 0; pn < 11; pn++ )
            log_printf( &logger, "%c", airflow.part_number[ pn ] );
        log_printf( &logger, "\r\n" );
        //lot number
        log_printf( &logger, "Lot number: " );
        for ( uint8_t pn = 0; pn < 7; pn++ )
            log_printf( &logger, "%c", airflow.lot_number[ pn ] );
        log_printf( &logger, "\r\n" );
        //pressure range
        log_printf( &logger, "Pressure range: %d\r\n", airflow.pressure_range );
        //output type
        log_printf( &logger, "Output type: %c\r\n", airflow.output_type );
        //scale factor
        log_printf( &logger, "Scale factor: %d\r\n", airflow.scale_factor );
        //calibration id
        log_printf( &logger, "Calibration ID: %s\r\n", airflow.calibration_id );
        //week
        log_printf( &logger, "Week: %d\r\n", ( int16_t )airflow.week );
        //year
        log_printf( &logger, "Year: %d\r\n", ( int16_t )airflow.year );
        //sequence number
        log_printf( &logger, "Sequence number: %d\r\n", airflow.sequence_number );
    }
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    log_info( &logger, " Application Task " );
}

Application Task

Reads differential pressure in Pa, atmospheric pressure in mBar and ambient temperature in C every 500ms and logs read data.

void application_task ( void ) 
{    
    float pressure_data, temperature_data;
    
    airflow_get_differential_pressure( &airflow, &pressure_data );
    log_printf( &logger, "Differential pressure[Pa]: %.2f\r\n", pressure_data );
    airflow_get_atmospheric_pressure( &airflow, &pressure_data, &temperature_data );
    log_printf( &logger, "Atmospheric pressure[mBar]: %.2f\r\nTemperature[degC]: %.2f\r\n", pressure_data, temperature_data );
    log_printf( &logger, "***********************************************************\r\n" );
    Delay_ms ( 500 );
}

Application Output

This Click board can be interfaced and monitored in two ways:

  • Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
  • UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.

Additional Notes and Information

The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.