\mainpage Main Page


Ambient 20 Click

Ambient 20 Click is a compact add-on board used to measure the amount of the present ambient light. This board features the BU27030NUC, a 16-bit digital-output ambient light sensor with an I2C interface from Rohm Semiconductor. The BU27030NUC has a flexible and wide operating range of up to 20klx with a maximum resolution of 0.0007lux/count, providing an excellent responsivity close to the human eyes' response. It also features inherent 50Hz/60Hz light noise rejection and excellent IR-cut characteristics for high robustness at high sensitivity.

Click Product page


Click library

  • Author : Stefan Ilic
  • Date : Nov 2022.
  • Type : I2C type

Software Support

We provide a library for the Ambient 20 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Ambient 20 Click driver.

Standard key functions :

  • ambient20_cfg_setup Config Object Initialization function.
void ambient20_cfg_setup ( ambient20_cfg_t *cfg );
  • ambient20_init Initialization function.
err_t ambient20_init ( ambient20_t *ctx, ambient20_cfg_t *cfg );
  • ambient20_default_cfg Click Default Configuration function.
err_t ambient20_default_cfg ( ambient20_t *ctx );

Example key functions :

  • ambient20_sw_reset Software reset function.
err_t ambient20_sw_reset ( ambient20_t *ctx );
  • ambient20_set_gain Set data gain function.
err_t ambient20_set_gain ( ambient20_t *ctx, uint8_t data0_gain, uint8_t data1_gain );
  • ambient20_read_data0 Read data0 function.
err_t ambient20_read_data0 ( ambient20_t *ctx, uint16_t *data0_out );

Example Description

This example demonstrates the use of Ambient 20 Click board by measuring the ambient light level.

The demo application is composed of two sections :

Application Init

Initializes the driver and performs the Click default configuration.

void application_init ( void ) 
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    ambient20_cfg_t ambient20_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    ambient20_cfg_setup( &ambient20_cfg );
    AMBIENT20_MAP_MIKROBUS( ambient20_cfg, MIKROBUS_1 );
    if ( I2C_MASTER_ERROR == ambient20_init( &ambient20, &ambient20_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    if ( AMBIENT20_ERROR == ambient20_default_cfg ( &ambient20 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }
    
    uint8_t id;
    ambient20_get_manufacturer_id( &ambient20, &id );
    
    log_printf( &logger, "- - - - - - - - - - - - -\r\n" );
    log_printf( &logger, " Part ID = 0x%.2X \r\n", ( uint16_t ) id );
    log_printf( &logger, "- - - - - - - - - - - - -\r\n" );

    log_info( &logger, " Application Task " );
    log_printf( &logger, "- - - - - - - - - - - - -\r\n" );
}

Application Task

Measuring ambient light level by reading DATA0 and DATA1 channels of the Ambient 20 Click board and displaying it using UART Serial terminal.

void application_task ( void ) 
{
    //  Task implementation.
    float data0, data1;
    ambient20_get_data_lux( &ambient20, &data0, &data1 );
    
    log_printf( &logger, "Data 0: %.2f lx \r\n", data0 );
    log_printf( &logger, "Data 1: %.2f lx \r\n", data1 );
    log_printf( &logger, "- - - - - - - - - - - - -\r\n" );
    
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.Ambient20

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.