GSM GNSS 2 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Mikroe Team
- Date : Mar 2022.
- Type : UART type
This example reads and processes data from GSM/GNSS 2 Clicks.
- MikroSDK.Board
- MikroSDK.Log
- Click.GSMGNSS2
gsmgnss2_cfg_setup
Config Object Initialization function.
void gsmgnss2_cfg_setup ( gsmgnss2_cfg_t *cfg );
gsmgnss2_init
Initialization function.
err_t gsmgnss2_init ( gsmgnss2_t *ctx, gsmgnss2_cfg_t *cfg );
gsmgnss2_module_power
Power ON/OFF the module.
void gsmgnss2_module_power ( gsmgnss2_t *ctx, uint8_t state );
gsmgnss2_send_cmd
Send command function.
void gsmgnss2_send_cmd ( gsmgnss2_t *ctx, char *cmd );
gsmgnss2_set_sim_apn
Set sim card APN.
void gsmgnss2_set_sim_apn ( gsmgnss2_t *ctx, char *sim_apn );
gsmgnss2_send_sms_pdu
GSM GNSS send SMS in PDU mode.
err_t gsmgnss2_send_sms_pdu ( gsmgnss2_t *ctx, char *service_center_number, char *phone_number, char *sms_text );
Initializes the driver and powers up the module, then sets default configuration for connecting the device to network.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
gsmgnss2_cfg_t gsmgnss2_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
gsmgnss2_cfg_setup( &gsmgnss2_cfg );
GSMGNSS2_MAP_MIKROBUS( gsmgnss2_cfg, MIKROBUS_1 );
gsmgnss2_init( &gsmgnss2, &gsmgnss2_cfg );
gsmgnss2_module_power( &gsmgnss2, GSMGNSS2_MODULE_POWER_ON );
// dummy read
gsmgnss2_process( );
gsmgnss2_clear_app_buf( );
// AT
gsmgnss2_send_cmd( &gsmgnss2, GSMGNSS2_CMD_AT );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// ATI - product information
gsmgnss2_send_cmd( &gsmgnss2, GSMGNSS2_CMD_ATI );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// CGMR - firmware version
gsmgnss2_send_cmd( &gsmgnss2, GSMGNSS2_CMD_CGMR );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// CMEE - Report Mobile Equipment Error
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CMEE, "2" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// COPS - deregister from network
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_COPS, "2" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// CGDCONT - set sim apn
gsmgnss2_set_sim_apn( &gsmgnss2, SIM_APN );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// CFUN - full funtionality
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CFUN, "1" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// COPS - automatic mode
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_COPS, "0" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
// CREG - network registration status
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CREG, "1" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// SMS message format - PDU mode
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CMGF, "0" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// QGNSSC - power ON GNSS
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CGNSPWR, "1" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
app_buf_len = 0;
app_buf_cnt = 0;
app_connection_status = WAIT_FOR_CONNECTION;
log_info( &logger, " Application Task " );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
Waits for the device to connect to network, then waits for the GNSS position fix. Once it get a fix, it sends an SMS with GNSS info to the selected phone number approximately every 40 seconds.
void application_task ( void )
{
if ( app_connection_status == WAIT_FOR_CONNECTION )
{
// CREG - network registration status
gsmgnss2_send_cmd_check( &gsmgnss2, GSMGNSS2_CMD_CREG );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 500 );
// CSQ - signal quality
gsmgnss2_send_cmd( &gsmgnss2, GSMGNSS2_CMD_CSQ );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
else
{
log_info( &logger, "CONNECTED TO NETWORK" );
for ( ; ; )
{
// Get GNSS info
gnss_parser_flag = 1;
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CGNSTST, "1" );
for ( ; ; )
{
if ( GSMGNSS2_OK == gsmgnss2_process( ) )
{
gnss_parser_application( app_buf );
if ( gnss_parser_flag == 2 )
{
gsmgnss2_send_cmd_with_parameter( &gsmgnss2, GSMGNSS2_CMD_CGNSTST, "0" );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
log_printf( &logger, "> Sending message to phone number...\r\n" );
gsmgnss2_send_sms_pdu ( &gsmgnss2, SIM_SMSC, PHONE_NUMBER_TO_MESSAGE, gnss_info_message );
app_error_flag = gsmgnss2_rsp_check( );
gsmgnss2_error_check( app_error_flag );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
if ( gnss_parser_flag != 1 )
{
break;
}
}
}
}
}
}
A passive GPS antenna is required for the GNSS to receive the position fix. It may take several minutes for the module to receive the fix. In order for the example to work, user needs to set the phone number to which he wants to send an SMS, and also will need to set an APN and SMSC (required for PDU mode only) of entered SIM card. Enter valid data for the following macros: SIM_APN, SIM_SMSC and PHONE_NUMBER_TO_MESSAGE.
Example:
- SIM_APN "vipmobile"
- SIM_SMSC "+381610401"
- PHONE_NUMBER_TO_MESSAGE "+381659999999"
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.