Skip to content

Latest commit

 

History

History

multisteppertb62262

Folders and files

NameName
Last commit message
Last commit date

parent directory

..
 
 
 
 
 
 
 
 
 
 
 
 
 
 

\mainpage Main Page


Multi Stepper TB62262 Click

Multi Stepper Click is a compact add-on board that contains a bipolar stepper motor driver. This board features the TB62262FTG, CLOCK-in controlled bipolar stepping motor driver from Toshiba Semiconductor. It supports a PWM constant-current control drive and allows full-, half-, and quarter-step operation for less motor noise and smoother control. It has a wide operating voltage range of 10V to 38V with an output current capacity of 1.2A in addition to several built-in error detection circuits.

Click Product page


Click library

  • Author : Stefan Filipovic
  • Date : Feb 2022.
  • Type : I2C type

Software Support

We provide a library for the Multi Stepper TB62262 Click as well as a demo application (example), developed using MikroElektronika compilers. The demo can run on all the main MikroElektronika development boards.

Package can be downloaded/installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Library Description

This library contains API for Multi Stepper TB62262 Click driver.

Standard key functions :

  • multisteppertb62262_cfg_setup Config Object Initialization function.
void multisteppertb62262_cfg_setup ( multisteppertb62262_cfg_t *cfg );
  • multisteppertb62262_init Initialization function.
err_t multisteppertb62262_init ( multisteppertb62262_t *ctx, multisteppertb62262_cfg_t *cfg );
  • multisteppertb62262_default_cfg Click Default Configuration function.
err_t multisteppertb62262_default_cfg ( multisteppertb62262_t *ctx );

Example key functions :

  • multisteppertb62262_set_step_mode This function sets the step mode resolution settings.
err_t multisteppertb62262_set_step_mode ( multisteppertb62262_t *ctx, uint8_t mode );
  • multisteppertb62262_drive_motor This function drives the motor for the specific number of steps at the selected speed.
void multisteppertb62262_drive_motor ( multisteppertb62262_t *ctx, uint32_t steps, uint8_t speed );
  • multisteppertb62262_set_direction This function sets the motor direction by setting the AN pin logic state.
void multisteppertb62262_set_direction ( multisteppertb62262_t *ctx, uint8_t dir );

Example Description

This example demonstrates the use of the Multi Stepper TB62262 Click board by driving the motor in both directions for a desired number of steps.

The demo application is composed of two sections :

Application Init

Initializes the driver and performs the Click default configuration.

void application_init ( void )
{
    log_cfg_t log_cfg;  /**< Logger config object. */
    multisteppertb62262_cfg_t multisteppertb62262_cfg;  /**< Click config object. */

    /** 
     * Logger initialization.
     * Default baud rate: 115200
     * Default log level: LOG_LEVEL_DEBUG
     * @note If USB_UART_RX and USB_UART_TX 
     * are defined as HAL_PIN_NC, you will 
     * need to define them manually for log to work. 
     * See @b LOG_MAP_USB_UART macro definition for detailed explanation.
     */
    LOG_MAP_USB_UART( log_cfg );
    log_init( &logger, &log_cfg );
    log_info( &logger, " Application Init " );

    // Click initialization.
    multisteppertb62262_cfg_setup( &multisteppertb62262_cfg );
    MULTISTEPPERTB62262_MAP_MIKROBUS( multisteppertb62262_cfg, MIKROBUS_1 );
    if ( I2C_MASTER_ERROR == multisteppertb62262_init( &multisteppertb62262, &multisteppertb62262_cfg ) ) 
    {
        log_error( &logger, " Communication init." );
        for ( ; ; );
    }
    
    if ( MULTISTEPPERTB62262_ERROR == multisteppertb62262_default_cfg ( &multisteppertb62262 ) )
    {
        log_error( &logger, " Default configuration." );
        for ( ; ; );
    }
    
    log_info( &logger, " Application Task " );
}

Application Task

Drives the motor clockwise for 200 steps and then counter-clockiwse for 100 steps with 2 seconds delay before changing the direction. Each step will be logged on the USB UART where you can track the program flow.

void application_task ( void )
{
    log_printf ( &logger, " Move 200 steps clockwise \r\n\n" );
    multisteppertb62262_set_direction ( &multisteppertb62262, MULTISTEPPERTB62262_DIR_CW );
    multisteppertb62262_drive_motor ( &multisteppertb62262, 200, MULTISTEPPERTB62262_SPEED_FAST );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
    
    log_printf ( &logger, " Move 100 steps counter-clockwise \r\n\n" );
    multisteppertb62262_set_direction ( &multisteppertb62262, MULTISTEPPERTB62262_DIR_CCW );
    multisteppertb62262_drive_motor ( &multisteppertb62262, 100, MULTISTEPPERTB62262_SPEED_FAST );
    Delay_ms ( 1000 );
    Delay_ms ( 1000 );
}

The full application code, and ready to use projects can be installed directly from NECTO Studio Package Manager(recommended way), downloaded from our LibStock™ or found on Mikroe github account.

Other Mikroe Libraries used in the example:

  • MikroSDK.Board
  • MikroSDK.Log
  • Click.MultiStepperTB62262

Additional notes and informations

Depending on the development board you are using, you may need USB UART Click, USB UART 2 Click or RS232 Click to connect to your PC, for development systems with no UART to USB interface available on the board. UART terminal is available in all MikroElektronika compilers.