Setting config values for Aeon ZW090-A always fails #1801

Closed
michael-fadely opened this issue May 16, 2019 · 2 comments
Closed

Setting config values for Aeon ZW090-A always fails #1801

michael-fadely opened this issue May 16, 2019 · 2 comments
Labels

Comments

@michael-fadely
Copy link

Attempting to change a configuration variable with the Aeon ZW090-A always fails. In the attached log, you can see that the option I tried to configure was LED indicator configuration.

OZW_Log.txt

I confirmed that the device is fully functional by testing this with Aeon's backup software. The LED indicator toggle in their software works every time.

@Fishwaldo
Copy link
Member

Unfortunately we can't change configuration values on the controller. Its a limitation of the SerialAPI protocol. The Aeotec utility has non-zwave packet it sends to the serial port to do this.

@michael-fadely
Copy link
Author

That would certainly explain it. Thank you!