my setup:
original pinecil v2 (tried 3 different)
firmware (3 different): 2.20 stock , 2.20 release and 2.21 release
original pine64 original short cartridge (tried 3 different)
cable tried 3: original pine64 1.5m type-c and baseus 2m 100W type-c (tried 2 different)
power supply tried 2: voltme 140w and meanwell lrs-350-24 (24v 350W)

after all the advice in pine64 support and pinecil chat temperature still range 340 to 360 when 350 was set

I clean all contact with IPA
did settings reset
calibrate temperature after 30 minutes of being turned off
heated to 350 stay for a few minutes then cool and again heated and repeated several times

also Tip K is unstable in the cold state and fluctuates +- 100 and in the heated state also has large fluctuations

Безымянный

@Ralim
Copy link
Owner

Ralim commented Jun 2, 2023

The raw tip reading will always have a few 10's to 100's of microvolts of instability due to how this all works.

The slow temperature oscillation is "normal" at the moment as the V2 needs a re-tune after a bunch of work that does done earlier. Just haven't had time to setup my unit to adjust the tuning values for the stabilisation filter. (There is no hardware issue here, and as it doesnt practically impact use has not been a high priority).

@Ralim Ralim closed this as completed in e7bcf92 Jun 4, 2023
@Ralim Ralim added this to the 2.22 milestone Jun 4, 2023
@Ralim
Copy link
Owner

Ralim commented Jun 4, 2023

Have done another tune, please try flashing the latest dev build and let me know how it performs for you

@cohaolain
Copy link
Contributor

Just tried e7bcf92 here on my Pinecil v2, with a target temperature of 360C I'm getting fluctuations with range between 350C and 380C, or wider. The period between power bursts seems to be quite long, roughly 3s or so - is that expected to still be so wide/long? Still seems to be much less smooth than before #1485 / #1535 (aside from the fluctuations solved by that PR, of course).

image

Thanks for your attention on this :)

@Ralim
Copy link
Owner

Ralim commented Jun 5, 2023

Hia,

Can you please confirm:
Power pulses are turned off in the menu
What tip your using
What your ambient temperature is
And
What power supply your using ?

@cohaolain
Copy link
Contributor

Hia,

Can you please confirm: Power pulses are turned off in the menu What tip your using What your ambient temperature is And What power supply your using ?

Just tested this again here to ensure everything lined up:

  • Ambient 22.6C
  • Target 360C
  • Observed temperature dropping to 345C and then jumping to 380C, with a period of (roughly) ~3s
  • Tip during this test is an ST-KU, cleaned with IPA.
  • Power pulses disabled
  • Power supply is a PinePower GaN (current revision), 65W available @ 20V

@Ralim
Copy link
Owner

Ralim commented Jun 12, 2023

Hmm, okay thats odd as it is not fluctuating like that for me, maybe a few (2 ish) C on the screen and tip tester shows smaller fluctuations again.

I dont have a ST-KU, just the longer ones or the ST-B2 tips here. One all of these it behaves well.

just to confirm, what version hash is shown in the debug menu for you?

@cohaolain
Copy link
Contributor

cohaolain commented Jun 12, 2023

V2.21.E7BCF92
04-06-23

@cohaolain
Copy link
Contributor

That's quite interesting indeed, I will try with an ST-B2 here but I can't imagine the difference will be so stark. Very curious.

@elpidifor have you tested the new version and seen an improvement?

@sddev0
Copy link

sddev0 commented Aug 7, 2023

I encounter the same issues with Pinecil V2 and IronOS 2.22:
This is the graph for v2.22C.4F2FB208 and ST-B2:
IMG_7588
I see slow fluctations with an amplitude of ~15°C with a period of ~3 seconds.

This is v2.21.5D96470:
IMG_7589

@sddev0
Copy link

sddev0 commented Aug 14, 2023

@Ralim: Can you reopen this issue? Which additional steps would be helpful to mitigate the issue?

@Ralim Ralim reopened this Aug 14, 2023
@Ralim
Copy link
Owner

Ralim commented Aug 14, 2023

Which additional steps would be helpful to mitigate the issue?

Test new tuning values for the tip if you have time to iterate.


and

I have had a few pokes and can replicate the issue but have not yet done any re-tuning yet.

@discip
Copy link
Collaborator

discip commented Aug 14, 2023

@elpidifor, @cohaolain, @sddev0
Please check the latest adaptations. 😊

@MabaKalox
Copy link

MabaKalox commented Sep 20, 2023

Same behaviour as @sddev0 have
v2.22
Target temp - 295
Temp fluctuates between - 280-312

V2.21
Target temp - 295
Temp fluctuates between 293-297

@Ralim
Copy link
Owner

Ralim commented Sep 20, 2023

Have you tested the PR looking to reduce these?
Would appreciate testing the PR, or helping to find new tuning values.

@dogtopus
Copy link
Contributor

dogtopus commented Sep 22, 2023

Just tried RC2. Didn't see any noticeable improvement compare to RC1. Running on PD power supply still gives around 7 degC swing and on EPR 10-12 degC. Mostly overshooting. I think it's still worse than on Pinecil v1 with the same tip and same PD power supply (IIRC Pinecil v1 never really broke +-3 degC).

This is measured on a TS100 chisel tip and not short tip. I imagine it would be worse on short tips.

@Ralim
Copy link
Owner

Ralim commented Sep 22, 2023

Ah good to know the tip.
Could you confirm the following:
Which tip code is on the tip?
If it was made by Pine64, Miniware or Others?
What device your using for measuring the tip temperature ?

@dogtopus
Copy link
Contributor

dogtopus commented Sep 22, 2023

It's a (probably genuine) Miniware TS-D24 I bought from Banggood ages ago.

I just used the internal temperature reading. Good tip thermometers are quite expensive.

EDIT: I also tried to use the thermocouple on my multimeter and measured the temperature directly on the tip (@200degC with Sn63Pb37 solder as the "thermal paste") and I can confirm the 7degC swing is still visible. So this probably rules out the possibility of bad internal thermocopule amplifier or driver.

@Ralim
Copy link
Owner

Ralim commented Sep 22, 2023

Thanks for the check.
Just wanted to narrow it down, as I have a handful of tips from aliexpress here that dont have the miniware logo on them that have quite poor sintering inside which oscillate a lot worse than this and wanted to rule it out.

I do intend to try and tune this more, but just genuinely havent had the days to spend on it.

@discip
Copy link
Collaborator

discip commented Sep 22, 2023

Have tested the latest c0a5e24 with the stock short tip (CJC calibrated).

Here are some results:
Screenshot from 2023-09-22 21-51-44

Screenshot from 2023-09-22 21-57-15

@discip
Copy link
Collaborator

discip commented Sep 23, 2023

Results with 07893da:

Screenshot from 2023-09-23 18-02-13
Screenshot from 2023-09-23 18-02-39

@dogtopus
Copy link
Contributor

I think #1820 makes the temperature swing slightly less (overall I see 2-3 degC reduction) but -5~+10 degC swing on EPR is still quite large.

Maybe there's still something to be done on the PID so it improves things further especially on the EPR end but with PD +-5 degC swing makes it somewhat passable already.

@dogtopus
Copy link
Contributor

dogtopus commented Oct 2, 2023

Just tested with all of my other tips. Some heavy tips bounce pretty wildly (specifically TS-K and the CNCKitchen TS100 heating element with large diameter threaded insert tip) but after that initial period Pinecil v2 is able to keep all of them at +-1degC. So looks like something is indeed wrong with my TS-D24. Maybe the thermocopule in it isn't binding with the tip properly or something. Not sure why it works normally on Pinecil v1 and TS100 but there is a pattern.

@goga1978
Copy link

Всем привет.

  1. Необходимо вводить список жал BC2, K, KU и других.
  2. Сделать нормальную калибровку жала по температурным точкам (450, 350, 250, 150)
  3. Ввести время обновления экрана 0.5сек , 1 сек , 2 сек. Чтобы показания не скакали.
  4. Ввести фильтрацию, скажем берем 20 значений , сортируем по возрастанию и берем значение из середины
    (246, 246 , 247, 247, 248, 248 , 248 , 249 , 249, 250, 250) = 248.

Hello everyone.

  1. It is necessary to enter a list of BC2, K, KU and other stings.
  2. Make a normal calibration of the tip by temperature points (450, 350, 250, 150)
  3. Enter the screen refresh time 0.5sec, 1 sec, 2 sec. So that the readings do not jump.
  4. Enter filtering, say we take 20 values, sort in ascending order and take the value from the middle
    (246, 246 , 247, 247, 248, 248 , 248 , 249 , 249, 250, 250) = 248.

@MayorBug
Copy link

With the 2.22 RC3 release I am getting random +100C spikes while heating up. Can upload few videos if requested.

@gamelaster
Copy link
Collaborator

@MayorBug video would be very useful, thanks!

@MayorBug
Copy link

Two clips here: https://drive.google.com/drive/folders/1KDNVOfujuvDA0yDg31WEw0SdJ5hT_KiB

You can see the +100C spikes around 220C

@Ralim Ralim mentioned this issue May 25, 2024
3 tasks
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

10 participants