The AM2320, AM2321 and AM2322 can also be read by using a "OneWire" protocol.
This protocol is identical to the DHT22 and will only provide a temperature,
a humidity and a CRC. See issue #26.
Spin off from -#26
For the AM2320 / 21 /22 something like
One Wire Protocol
The AM2320, AM2321 and AM2322 can also be read by using a "OneWire" protocol.
This protocol is identical to the DHT22 and will only provide a temperature,
a humidity and a CRC. See issue #26.
If one wants to use this protocol, one can use https://github.com/RobTillaart/DHTNew
and optionally force the type to 22.
The text was updated successfully, but these errors were encountered: