Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathReadmeShimmerBiophysicalProcessingLibrary.txt
178 lines (120 loc) · 6.62 KB
/
ReadmeShimmerBiophysicalProcessingLibrary.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
Shimmer Biophysical Processing Library (Close source code)
REV 0.10 (ShimmerBiophysicalProcessingLibrary_Rev_0_10.jar)
Changes since REV0.9
- added ECGtpHRAdaptive, note this is a more accurate and efficient vs ECGtoHRAlgorithm.
- ECGtoHRAlgorithm can be deprecated
Changes since REV0.8
- repackaged not to include data folder
INCLUDES THE FOLLOWING CLASSES
- PPGtoHRAlgorithm
- ECGtoHRAlgorithm (Deprecated)
- ECGtoHRAdaptive
**********************************************
ECGtoHRAdaptive
Rev0.1
11/09/2015
***********************************************
This algorithm calculates heart rate from calibrated ECG data.
It is recommended that the input ECG signal is filtered prior to calling the method ecgToHrConversion
*Constructors
1. ECGtoHRAdaptive(double samplingRate)
2. ECGtoHRAdaptive(double samplingRate, int HRWindowSize)
Where,
samplingRate: sampling rate in Hz
HRVWindowSize: size of window (in milliseconds) for calculating HRV metric
*Function calls
double heartRate = ecgToHrConversion(double ecgData, double ecgTimeStamp)
computes heart rate
ecgData is ECG data
ecgTimeStamp is the time stamp for the ecg data in milliSeconds
data fed in sample by sample
heartRate is in BPM
double[] heartRate = ecgToHrConversion(double[] ecgData, double[] ecgTimeStamp)
same functionality as above but takes in array of ecgData and ecgTimeStamp and returns array of heart rates
reset()
Clears the algorithm buffers and resets variables to initial values.
setParameters(double rate)
will reset all variables stored in the class
**********************************************
PPGtoHRAlgorithm
Rev0.10
08/05/2015
***********************************************
This algorithm calculates heart rate from calibrated PPG data.
It is recommended that the input PPG signal is filtered prior to calling the method ppgToHrConversion
- Has been tested with second order Chebyshev LPF with corner freq 5Hz and second order Chebyshev HPF with corner freq 0.5Hz
*Constructors
1. PPGtoHRAlgorithm(double samplingRate)
2. PPGtoHRAlgorithm(double samplingRate, int numberOfBeatsToAve)
3. PPGtoHRAlgorithm(double samplingRate, int numberOfBeatsToAve,int trainingInterval) //training interval is legacy support
4. PPGtoHRAlgorithm(double samplingRate, int numberOfBeatsToAve, boolean useLastEstimate)
Where,
samplingRate: sampling rate in Hz
numberOfBeatsToAve: the number of consecutive heart beats that are averaged to calculate the heart rate.
(instantaneous heart rate is calculated after each detected pulse. So the last X instantaneous heart rates are averaged to give the output (where X is numberOfBeatsToAve))
must be >= 1.
typical value would be ~ 5.
trainingInterval: Legacy support (no effect on algorithm performance).
useLastEstimate: True for repeating last valid estimate when invalid data is detected.
default values: numberOfBeatsToAve = 5
*FUNCTION CALLS
double heartRate = ppgToHrConversion(double ppgData, double ppgTimeStamp)
computes heart rate
ppgData is calibrated PPG data
ppgTimeStamp is the time stamp for the ppg data in milliSeconds
data fed in sample by sample
returns -1 until training period is complete (i.e this has been called (trainingInterval*rate) times)
also returns -1 if heartRate<30 or heartRate>215 or standard deviation of last X interbeat intervals > 100 (X = numberOfBeatsToAve and 100 is in ms)
heartRate is in BPM
double[] heartRate = ppgToHrConversion(double[] ppgData, double[] ppgTimeStamp)
same functionality as above but takes in array of ppgData and ppgTimeStamp and returns array of heart rates
resetParameters()
resets all parameters stored in the class
setParameters(double rate, int numberOfBeatsToAve,int trainingInterval)
same inputs as constructor
will reset all variables stored in the class
retrain ()
forces the ppg to hr algorithm to retrain, during which the heart rate is set to -1
-----------------------------------------------------------------------------------------------------------------------------------------------------------
DEPRECATED PLEASE USE ECGtoHRAdaptive
**********************************************
ECGtoHRAlgorithm
Rev0.11
08/05/2015
***********************************************
This algorithm calculates heart rate from calibrated ECG data.
It is recommended that the input ECG signal is filtered prior to calling the method ecgToHrConversion
*Constructors
1. ECGtoHRAlgorithm(double samplingRate)
2. ECGtoHRAlgorithm(double samplingRate, int trainingInterval, int statisticalLimitTestBufferSize)
3. ECGtoHRAlgorithm(double samplingRate, int trainingInterval, int statisticalLimitTestBufferSize, boolean useLastEstimate)
Where,
samplingRate: sampling rate in Hz
trainingInterval: of which to determine characteristics of R peak which is used to calculate heart rate. Training interval is in seconds
statisticalLimitTestBufferSize: number of interbeat intervals used in statistical test
see function setStaticticalLimitsTest below for further details
default values: trainingInterval = 10 secs
see function setStaticticalLimitsTest below for further details on default values for statistical test
useLastEstimate: True for repeating last valid estimate when invalid data is detected.
*Function calls
double heartRate = ecgToHrConversion(double ecgData, double ecgTimeStamp)
computes heart rate
ecgData is ECG data
ecgTimeStamp is the time stamp for the ecg data in milliSeconds
data fed in sample by sample
returns -1 until training period is complete
also returns -1 if statistical test fails. See function setStaticticalLimitsTest below for further details
heartRate is in BPM
double[] heartRate = ecgToHrConversion(double[] ecgData, double[] ecgTimeStamp)
same functionality as above but takes in array of ecgData and ecgTimeStamp and returns array of heart rates
resetParameters()
resets all parameters stored in the class
setParameters(double rate, int trainingInterval)
same inputs as constructor
will reset all variables stored in the class
setStaticticalLimitsTest(int testLimit, int statisticalLimitTestBufferSize, int heartRateUpperLimitTest, int heartRateLowerLimitTest){
Used to set the statistical test for calculated heart rates.
Calculated heart rate is set to -1 if heartRate<heartRateLowerLimitTest or heartRate>heartRateUpperLimitTest or standard deviation of last X interbeat intervals > testLimit (X = statisticalLimitTestBufferSize; and testLimit is in ms)
By default testlimit is set to 100ms, upperHearRateLimit is 215, LowerHeartRate is 30 and statisticalLimitTestBufferSize is 1
retrain ()
forces the ecg to hr algorithm to retrain, during which the heart rate value is set to -1