Notifications
You must be signed in to change notification settings - Fork 4
/
Copy pathplotandwriteemgexample.m
176 lines (136 loc) · 10.7 KB
/
plotandwriteemgexample.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
function shimmer = plotandwriteemgexample(comPort, captureDuration, fileName)
%PLOTANDWRITEEMGEXAMPLE - Plotting ecg signal and write to file
% INPUT: comPort - String value defining the COM port number for Shimmer
%
% INPUT: captureDuration - Numerical value defining the capture duration
%
% INPUT: fileName - String value defining the name of the data file
%
% OUTPUT: shimmer - Object of the ShimmerHandleClass
%
% Example for Shimmer3
addpath('./Resources/') % directory containing supporting functions
%% definitions
shimmer = ShimmerHandleClass(comPort);
SensorMacros = SetEnabledSensorsMacrosClass; % assign user friendly macros for setenabledsensors
fs = 512; % sample rate in [Hz]
firsttime = true;
% Note: these constants are only relevant to this examplescript and are not used
% by the ShimmerHandle Class
NO_SAMPLES_IN_PLOT = 5000; % Number of samples in the plot
DELAY_PERIOD = 0.2; % Delay (in seconds) between data read operations
numSamples = 0;
%% settings
% filtering settings
fm = 50; % mains frequency [Hz]
fchp = 5; % corner frequency highpassfilter [Hz]; Shimmer recommends 5Hz to remove DC-offset and movement artifacts
nPoles = 4; % number of poles (HPF, LPF)
pbRipple = 0.5; % pass band ripple (%)
HPF = true; % enable (true) or disable (false) highpass filter
LPF = true; % enable (true) or disable (false) lowpass filter
BSF = true; % enable (true) or disable (false) bandstop filter
% highpass filters for ExG channels
if (HPF)
hpfexg1ch1 = FilterClass(FilterClass.HPF,fs,fchp,nPoles,pbRipple);
hpfexg1ch2 = FilterClass(FilterClass.HPF,fs,fchp,nPoles,pbRipple);
end
if (LPF)
% lowpass filters for ExG channels
lpfexg1ch1 = FilterClass(FilterClass.LPF,fs,fs/2-1,nPoles,pbRipple);
lpfexg1ch2 = FilterClass(FilterClass.LPF,fs,fs/2-1,nPoles,pbRipple);
end
if (BSF)
% bandstop filters for ExG channels;
% cornerfrequencies at +1Hz and -1Hz from mains frequency
bsfexg1ch1 = FilterClass(FilterClass.LPF,fs,[fm-1,fm+1],nPoles,pbRipple);
bsfexg1ch2 = FilterClass(FilterClass.LPF,fs,[fm-1,fm+1],nPoles,pbRipple);
end
%%
if (shimmer.connect)
shimmer.setsamplingrate(fs); % Select sampling rate
shimmer.setinternalboard('EMG'); % Select internal expansion board; select 'EMG' to enable SENSOR_EXG1
shimmer.disableallsensors; % Disable other sensors
shimmer.setenabledsensors(SensorMacros.EMG,1); % Enable SENSOR_EXG1, disable other sensors
if (shimmer.start) % TRUE if the shimmer starts streaming
plotData = [];
timeStamp = [];
filteredplotData = [];
h.figure1=figure('Name','Shimmer EMG signals'); % Create a handle to figure for plotting data from shimmer
set(h.figure1, 'Position', [100, 500, 800, 400]);
elapsedTime = 0; % Reset to 0
tic; % Start timer
while (elapsedTime < captureDuration)
pause(DELAY_PERIOD); % Pause for this period of time on each iteration to allow data to arrive in the buffer
% [newData,signalNameArray,signalFormatArray,signalUnitArray] = shimmer.getdata('Time Stamp','c','ECG','c'); % Read the latest data from shimmer data buffer, signalFormatArray defines the format of the data and signalUnitArray the unit
% or use
[newData,signalNameArray,signalFormatArray,signalUnitArray] = shimmer.getdata('c'); % Read the latest data from shimmer data buffer, signalFormatArray defines the format of the data and signalUnitArray the unit
if (firsttime==true && isempty(newData)~=1)
firsttime = writeHeadersToFile(fileName,signalNameArray,signalFormatArray,signalUnitArray);
end
if ~isempty(newData) % TRUE if new data has arrived
chIndex(1) = find(ismember(signalNameArray, 'EMG CH1'));
chIndex(2) = find(ismember(signalNameArray, 'EMG CH2'));
EMGData = newData(:,chIndex);
EMGDataFiltered = EMGData;
% filter the data
if HPF % filter newData with highpassfilter to remove DC-offset
EMGDataFiltered(:,1) = hpfexg1ch1.filterData(EMGDataFiltered(:,1));
EMGDataFiltered(:,2) = hpfexg1ch2.filterData(EMGDataFiltered(:,2));
end
if BSF % filter highpassfiltered data with bandstopfilter to suppress mains interference
EMGDataFiltered(:,1) = bsfexg1ch1.filterData(EMGDataFiltered(:,1));
EMGDataFiltered(:,2) = bsfexg1ch2.filterData(EMGDataFiltered(:,2));
end
if LPF % filter bandstopfiltered data with lowpassfilter to avoid aliasing
EMGDataFiltered(:,1) = lpfexg1ch1.filterData(EMGDataFiltered(:,1));
EMGDataFiltered(:,2) = lpfexg1ch2.filterData(EMGDataFiltered(:,2));
end
dlmwrite(fileName, newData, '-append', 'delimiter', '\t','precision',16); % Append the new data to the file in a tab delimited format
plotData = [plotData; EMGData]; % Update the plotData buffer with the new ECG data
filteredplotData = [filteredplotData; EMGDataFiltered]; % Update the filteredplotData buffer with the new filtered ECG data
numPlotSamples = size(plotData,1);
numSamples = numSamples + size(newData,1);
timeStampNew = newData(:,1); % get timestamps
timeStamp = [timeStamp; timeStampNew];
if numSamples > NO_SAMPLES_IN_PLOT
plotData = plotData(numPlotSamples-NO_SAMPLES_IN_PLOT+1:end,:);
filteredplotData = filteredplotData(numPlotSamples-NO_SAMPLES_IN_PLOT+1:end,:);
end
sampleNumber = max(numSamples-NO_SAMPLES_IN_PLOT+1,1):numSamples;
set(0,'CurrentFigure',h.figure1);
subplot(2,2,1); % Create subplot
signalIndex = chIndex(1);
plot(sampleNumber,plotData(:,1)); % Plot the ecg for channel 1 of SENSOR_EXG1
legendName1=[signalFormatArray{signalIndex} ' ' signalNameArray{signalIndex} ' (' signalUnitArray{signalIndex} ')'];
legend(legendName1); % Add legend to plot
xlim([sampleNumber(1) sampleNumber(end)]);
subplot(2,2,2); % Create subplot
signalIndex = chIndex(2);
plot(sampleNumber,plotData(:,2)); % Plot the ecg for channel 2 of SENSOR_EXG1
legendName1=[signalFormatArray{signalIndex} ' ' signalNameArray{signalIndex} ' (' signalUnitArray{signalIndex} ')'];
legend(legendName1); % Add legend to plot
xlim([sampleNumber(1) sampleNumber(end)]);
subplot(2,2,3); % Create subplot
signalIndex = chIndex(1);
plot(sampleNumber,filteredplotData(:,1)); % Plot the filtered ecg for channel 1 of SENSOR_EXG1
legendName1=[signalFormatArray{signalIndex} ' ' 'filtered' ' ' signalNameArray{signalIndex} ' (' signalUnitArray{signalIndex} ')'];
legend(legendName1); % Add legend to plot
xlim([sampleNumber(1) sampleNumber(end)]);
subplot(2,2,4); % Create subplot
signalIndex = chIndex(2);
plot(sampleNumber,filteredplotData(:,2)); % Plot the filtered ecg for channel 2 of SENSOR_EXG1
legendName1=[signalFormatArray{signalIndex} ' ' 'filtered' ' ' signalNameArray{signalIndex} ' (' signalUnitArray{signalIndex} ')'];
legend(legendName1); % Add legend to plot
xlim([sampleNumber(1) sampleNumber(end)]);
end
elapsedTime = elapsedTime + toc; % Update elapsedTime with the time that elapsed since starting the timer
tic; % Start timer
end
elapsedTime = elapsedTime + toc; % Update elapsedTime with the time that elapsed since starting the timer
fprintf('The percentage of received packets: %d \n',shimmer.getpercentageofpacketsreceived(timeStamp)); % Detect loss packets
shimmer.stop; % Stop data streaming
end
end
shimmer.disconnect;
clear shimmer ;
end % plotandwriteemgexample