I am using the tiatoolbox to implement the automatic tumor contouring pipeline for lung H&E images. The pipeline includes the following steps:
Patch extraction
Patch prediction
Prediction merging
When merging the predictions, in some cases, the patches are not located at the right coordinate and they are clearly shifted. Also, in very few cases, coordinated_list and predicted_patches have different sizes. I was wondering if you faced this issue before or have any idea why this issue is happening.
Here is the code I use for prediction merging:
#read WSI and calculate the wsi_size at the working resolution
wsi_reader= WSIReader.open(input_img=wsi_path)
wsi_size= wsi_reader.slide_dimensions(resolution=working_resolution,units="mpp")
#read the mask and calculate the scale factor
mask_img= tifffile.imread(mask_path)
scale_factor= np.array(wsi_size) / mask_img.shape[:2][::-1]
#create the patchextractor object with the working_resolution used to train the model
fixed_patch_extractor= patchextraction.get_patch_extractor(input_img=wsi_reader,
method_name="slidingwindow",
patch_size=patch_size,
input_mask=mask_img,
resolution=working_resolution,
stride=stride,
units="mpp")
#get the coordinate list for the patches
coordinate_list= fixed_patch_extractor.get_coordinates(
image_shape=wsi_size,
patch_input_shape=(4096,4096),
stride_shape=(4000,4000),
)
#generate the virtual wsi reader for the mask image at the working resolution,
#the mask reader will be used to correct the the coordinate_list
mask_data_resized= imresize(mask_img,scale_factor)
mask_reader= VirtualWSIReader(mask_data_resized,mpp=wsi_reader.info.mpp[0])
#filter the coordinates if a mask is used for patch extraction
if mask_img is not None:
selected_coord_indices =fixed_patch_extractor.filter_coordinates_fast(
mask_reader,
coordinate_list,
coordinate_resolution=wsi_reader.info.mpp[0],
coordinate_units="mpp")
corrected_coordinate_list =coordinate_list[selected_coord_indices]
#read the patch predictions
predictions= []
for pred in sorted(os.listdir(prediction_path)):
prediction = imread(pre)[:,:,0]
predictions.append(prediction)
#create the patch predictor object to call merge_predictionfunction
output= {
'resolution':working_resolution,
'units':'mpp',
'predictions':np.asarray(predictions),
'coordinates':np.asarray(corrected_coordinate_list),
}
#when generating the patches, we apply padding.
#Therefore, we need to consider it when merging the predictions
#later we will get back to the original wsi_size before downsampling the prediction
wsi_size_padded= (coordinate_list[-1][2],coordinate_list[-1][3])
merged_img= np.transpose(np.zeros(wsi_size_padded))
merged_reader= VirtualWSIReader(merged_img,mpp=working_resolution)
merged= PatchPredictor.merge_predictions(merged_reader,
output,
resolution=working_resolution,
units='mpp')
save_path= os.path.join(output_folder,sub+ "_merged_ds.tif")
#get back to the wsi_size by removing the padded part
modified_merged= merged[0:wsi_size[1],0:wsi_size[0]]
#down-sample the merged prediction to be the same size as the GT mask
modified_merged_ds= imresize(modified_merged,1/scale_factor)
io.imsave(save_path,modified_merged_ds,check_contrast=False)
The text was updated successfully, but these errors were encountered:
Description
I am using the tiatoolbox to implement the automatic tumor contouring pipeline for lung H&E images. The pipeline includes the following steps:
When merging the predictions, in some cases, the patches are not located at the right coordinate and they are clearly shifted. Also, in very few cases, coordinated_list and predicted_patches have different sizes. I was wondering if you faced this issue before or have any idea why this issue is happening.
Here is the code I use for prediction merging:
The text was updated successfully, but these errors were encountered: