Alarm 4229[40]
(ETHERNET PROCESS ERROR
) with MR2 installed, but LAN not connected
#174
Comments
Perhaps @tingelst can add something: it's "his" setup and the author of the report was his MSc student. |
@gavanderhoorn, I can confirm that this is still an issue with the latest release installed. I'll have my current master's students do some debugging and report back. |
Thanks @tingelst. Could you please ask them to post a comment with some information about the controller used? Software versions, how are the two Fronius devices are connected, etc? Unfortunately we can't ask for the debug log, as that would require a working LAN connection. |
@tingelst: I've updated the OP with the information from the manual. From the possible cause description this sounds like a regular alarm where MotoROS2 would not affect anything (as in: if DHCP is supposed to be used, but there is no ethernet connection, it's not going to work and the controller is "correct" to complain). It'd be valuable to know what happens without MR2 installed on the controller in case there is no connection to any of the LAN ports (although the alarm sub code description specifically mentions |
Friendly ping @tingelst? |
@gavanderhoorn We've been out of the lab this week. Will report back, Monday/Tuesday upcoming week. |
I suspect you are right here. LAN2 is currently set to DHCP. Will test if changing that to a static IP addresses the error. |
Would perhaps also be nice to know whether the same alarm is raised in case MotoROS2 is not installed, DHCP is still enabled for |
Friendly ping again @tingelst :) |
I was able to remove the alarm by setting LAN2 to manual and not DHCP on the said system. On a second cell without MotoROS2 installed, I set LAN2 to DHCP without network connection. This did not raise any alarm. |
Thanks.
seems there is something we're doing with MotoROS2 which makes the OS raise this specific alarm. We'll need to investigate. Could you perhaps attach a copy of the |
Likely the fact that MR2 is trying to access network features when there's no address. |
Here it is: PANELBOX.LOG |
This is a report by proxy, as I've only found this by reading Multi-Robot Control with MotoROS2, an MSc thesis report.
According to the author of that report, the YRC1 used in his/her experiments raises
4229[40]
(ETHERNET PROCESS ERROR
) in case MotoROS2 is installed but none of the network ports have an active connection (ie: have a plugged in Ethernet cable). Only after connecting a cable to the LAN port (I guess either, but there are no details in the report about this) does the alarm stop getting posted.This is described in Section
8.7
, with the error shown in Figure8.7
.Note that this was with MotoROS2
beta1
verion0.0.15
, so quite some time ago.I do believe this is something to check though and make sure is no longer a problem with MotoROS2.
Unfortunately no details about controller sw are present in the report, other than it's a 4 group system (2xGP25, TSL 600 and an MT1) with a Fronius TP400i and a MagicWave 3000.
Edit: for completeness, the description of
4229[40]
from the YRC1000 alarm codes manual (178644-1CD
rev1):The text was updated successfully, but these errors were encountered: