Yes.
If S1CxG0335 is not set, then GP_getFeedbackSpeedMRegisterAddresses will attempt to directly modify the SC.PRM file in the controller. After that modification, it raises an alarm and sits in an infinite (blocking) loop to force the user to reboot.
But...
a) The user didn't see the alarm. Don't know why...
b) Since the FSU CRC-check was enabled, the modification to SC.PRM was never accepted. So MR2 gets stuck in the bootup routine.
If the pendant isn't properly displaying the alarm, then I don't know that we'll be able to fix that directly. (Will need to report to Japan.) But we can ensure that the debug message gets reported in a way that is visible to the user.
Alternatively (or additionally), we can modify the setup instructions to have users manually enable the speed-feedback parameters.
What about extending GP_getFeedbackSpeedMRegisterAddresses(..) to not
attempt to directly modify the SC.PRM file in the controller. After that modification, it raises an alarm and sits in an infinite (blocking) loop to force the user to reboot.
but instead just return an error? That can then be forwarded / reported to the user in the normal way.
Since the FSU CRC-check was enabled, the modification to SC.PRM was never accepted. So MR2 gets stuck in the bootup routine.
is there a way to detect the FSU is enabled? If there is, we can report that as well.
Alternatively (or additionally), we can modify the setup instructions to have users manually enable the speed-feedback parameters.
I'd really only do that as a last resort. There's quite a few parameters, especially when you have multiple axes.
We had a user get into this scenario. But he reports that he never saw the alarm,
8001 Speed FB enabled, reboot now. [10]
#294 (comment)
This results in MR2 appearing to freeze at startup and communication dropping to the agent.
The only way that I know it occurred was by looking through the alarm history.
I too believe that I have seen this scenario, but I just brushed it off and assumed that I wasn't paying attention.
We need to try to reproduce with a "clean" robot controller that has FSU enabled.