Introduced in v6.7.1
Fast power cycle device recovery is implemented for situations where a device cannot be reset to firmware defaults (no serial access, no button). It resets all Tasmota settings (equal to Reset 1
) after 4 power cycles.
SetOption65
must be set to 0
(default) in order for this feature to be enabled.
- Cut power from the device completely for 30 seconds
- Power the device on and off three times with intervals lower than 10 seconds and leave it on after fourth time
- Fast power cycle device recovery should activate and the device should be reset to firmware defaults
If you flashed a precompiled binary you can reconfigure the device using the web UI.