From 974b2fabcafa41d24d4fcb61e02ece9d0650ad15 Mon Sep 17 00:00:00 2001 From: Stefan Appelhoff Date: Tue, 20 Jul 2021 10:19:13 +0200 Subject: [PATCH] misc: make explicit that EDF+ and BDF+ are included --- src/04-modality-specific-files/03-electroencephalography.md | 6 ++++-- .../04-intracranial-electroencephalography.md | 5 +++-- 2 files changed, 7 insertions(+), 4 deletions(-) diff --git a/src/04-modality-specific-files/03-electroencephalography.md b/src/04-modality-specific-files/03-electroencephalography.md index ea1642ce22..522a59e87b 100644 --- a/src/04-modality-specific-files/03-electroencephalography.md +++ b/src/04-modality-specific-files/03-electroencephalography.md @@ -24,7 +24,8 @@ no single standard that all researchers agree on. For BIDS, EEG data MUST be stored in one of the following formats: - [European data format](https://www.edfplus.info/) - (Each recording consisting of a `.edf` file) + (including [`edf+`](https://www.edfplus.info/specs/edfplus.html); + each recording consisting of a `.edf` file) - [BrainVision Core Data Format](https://www.brainproducts.com/productdetails.php?id=21&tab=5) (Each recording consisting of a `.vhdr`, `.vmrk`, `.eeg` file triplet) @@ -33,7 +34,8 @@ stored in one of the following formats: (Each recording consisting of a `.set` file with an optional `.fdt` file) - [Biosemi](https://www.biosemi.com/) data format - (Each recording consisting of a `.bdf` file) + (including [`bdf+`](https://www.teuniz.net/edfbrowser/bdfplus%20format%20description.html); + each recording consisting of a `.bdf` file) It is RECOMMENDED to use the European data format, or the BrainVision data format. It is furthermore discouraged to use the other accepted formats over diff --git a/src/04-modality-specific-files/04-intracranial-electroencephalography.md b/src/04-modality-specific-files/04-intracranial-electroencephalography.md index 43cfc9ae63..dae9afffb8 100644 --- a/src/04-modality-specific-files/04-intracranial-electroencephalography.md +++ b/src/04-modality-specific-files/04-intracranial-electroencephalography.md @@ -14,8 +14,9 @@ The iEEG community uses a variety of formats for storing raw data, and there is no single standard that all researchers agree on. For BIDS, iEEG data MUST be stored in one of the following formats: -- [European Data Format](https://www.edfplus.info/) - (Each recording consisting of a `.edf` file) +- [European data format](https://www.edfplus.info/) + (including [`edf+`](https://www.edfplus.info/specs/edfplus.html); + each recording consisting of a `.edf` file) - [BrainVision Core Data Format](https://www.brainproducts.com/productdetails.php?id=21&tab=5) (Each recording consisting of a `.vhdr`, `.vmrk`, `.eeg` file triplet)