Technical details

  • Version:3.6.0
  • Module: Dicentrics/Dose estimation

Issue description

Suggestion (not an issue):
For Partial body assessment, three result tables are shown :
1. yield table,
2. dose table
3. and initial fraction of irradiated cells table.

It could be nice to add a fourth table (between the second and the third) showing the ratio of metaphases observed which belong to the irradiated fraction (ie belonging to the "decontaminated" Poisson distribution). This value is for sure already calculated as it is use for the estimation of the "initial fraction of irradiated blood" based on survival coefficient.
This could be helpfull in case of assessment of simulated distributions, to check that all went well.

In fact, this ratio is already given for "heterogeneous assessment" result tables, in the first table, column "frac", but not for partial.

@aldomann aldomann added this to the 3.6.1 milestone May 12, 2022
@aldomann aldomann added the enhancement New feature or request label May 12, 2022