Notifications
You must be signed in to change notification settings - Fork 6
/
prometheus.rules.template
347 lines (263 loc) · 12.6 KB
/
prometheus.rules.template
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
# https://awesome-prometheus-alerts.grep.to/rules
groups:
- name: NodeUsage
rules:
- alert: HostOutOfMemory
expr: node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of memory (instance {{ $labels.instance }})"
description: "Node memory is filling up (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostMemoryUnderMemoryPressure
expr: rate(node_vmstat_pgmajfault[2m]) > 1000
for: 5m
labels:
severity: warning
annotations:
summary: "Host memory under memory pressure (instance {{ $labels.instance }})"
description: "The node is under heavy memory pressure. High rate of major page faults\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualNetworkThroughputIn
expr: sum by (instance) (irate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual network throughput in (instance {{ $labels.instance }})"
description: "Host network interfaces are probably receiving too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualNetworkThroughputOut
expr: sum by (instance) (irate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual network throughput out (instance {{ $labels.instance }})"
description: "Host network interfaces are probably sending too much data (> 100 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskReadRate
expr: sum by (instance) (irate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk read rate (instance {{ $labels.instance }})"
description: "Disk is probably reading too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskWriteRate
expr: sum by (instance) (irate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk write rate (instance {{ $labels.instance }})"
description: "Disk is probably writing too much data (> 50 MB/s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostOutOfDiskSpace
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of disk space (instance {{ $labels.instance }})"
description: "Disk is almost full (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostDiskWillFillIn4Hours
expr: predict_linear(node_filesystem_free_bytes{fstype!~"tmpfs"}[1h], 4 * 3600) < 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host disk will fill in 4 hours (instance {{ $labels.instance }})"
description: "Disk will fill in 4 hours at current write rate\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostOutOfInodes
expr: node_filesystem_files_free / node_filesystem_files * 100 < 10
for: 5m
labels:
severity: warning
annotations:
summary: "Host out of inodes (instance {{ $labels.instance }})"
description: "Disk is almost running out of available inodes (< 10% left)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskReadLatency
expr: rate(node_disk_read_time_seconds_total[2m]) / rate(node_disk_reads_completed_total[2m]) > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk read latency (instance {{ $labels.instance }})"
description: "Disk latency is growing (read operations > 100ms)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostUnusualDiskWriteLatency
expr: rate(node_disk_write_time_seconds_total[2m]) / rate(node_disk_writes_completed_total[2m]) > 100
for: 5m
labels:
severity: warning
annotations:
summary: "Host unusual disk write latency (instance {{ $labels.instance }})"
description: "Disk latency is growing (write operations > 100ms)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostHighCpuLoad
expr: 100 - (avg by(instance) (irate(node_cpu_seconds_total{mode="idle"}[5m])) * 100) > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Host high CPU load (instance {{ $labels.instance }})"
description: "CPU load is > 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
# 1000 context switches is an arbitrary number.
# Alert threshold depends on nature of application.
# Please read: https://github.com/samber/awesome-prometheus-alerts/issues/58
- alert: HostContextSwitching
expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 2000
for: 5m
labels:
severity: warning
annotations:
summary: "Host context switching (instance {{ $labels.instance }})"
description: "Context switching is growing on node (> 1000 / s)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostSwapIsFillingUp
expr: (1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Host swap is filling up (instance {{ $labels.instance }})"
description: "Swap is filling up (>80%)\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
# node_systemd_* not enabled by default due to kernel configuration and
# security settings,
# https://github.com/prometheus/node_exporter#disabled-by-default
- alert: HostSystemdServiceCrashed
expr: node_systemd_unit_state{state="failed"} == 1
for: 5m
labels:
severity: warning
annotations:
summary: "Host SystemD service crashed (instance {{ $labels.instance }})"
description: "SystemD service crashed\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
# node_hwmon_* requires lm_sensors package
- alert: HostPhysicalComponentTooHot
expr: node_hwmon_temp_celsius > 75
for: 5m
labels:
severity: warning
annotations:
summary: "Host physical component too hot (instance {{ $labels.instance }})"
description: "Physical hardware component too hot\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostNodeOvertemperatureAlarm
expr: node_hwmon_temp_crit_alarm_celsius == 1
for: 5m
labels:
severity: critical
annotations:
summary: "Host node overtemperature alarm (instance {{ $labels.instance }})"
description: "Physical node temperature alarm triggered\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostRaidArrayGotInactive
expr: node_md_state{state="inactive"} > 0
for: 5m
labels:
severity: critical
annotations:
summary: "Host RAID array got inactive (instance {{ $labels.instance }})"
description: "RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostRaidDiskFailure
expr: node_md_disks{state="fail"} > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host RAID disk failure (instance {{ $labels.instance }})"
description: "At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostKernelVersionDeviations
expr: count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1
for: 5m
labels:
severity: warning
annotations:
summary: "Host kernel version deviations (instance {{ $labels.instance }})"
description: "Different kernel versions are running\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
# node_vmstat_oom_kill seems to need kernel 4.10.15 and newer
# https://github.com/prometheus/node_exporter/pull/874#issuecomment-377333109
- alert: HostOomKillDetected
expr: increase(node_vmstat_oom_kill[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host OOM kill detected (instance {{ $labels.instance }})"
description: "OOM kill detected\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostEdacCorrectableErrorsDetected
expr: increase(node_edac_correctable_errors_total[5m]) > 0
for: 5m
labels:
severity: info
annotations:
summary: "Host EDAC Correctable Errors detected (instance {{ $labels.instance }})"
description: "{{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostEdacUncorrectableErrorsDetected
expr: node_edac_uncorrectable_errors_total > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})"
description: "{{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostNetworkReceiveErrors
expr: increase(node_network_receive_errs_total[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host Network Receive Errors (instance {{ $labels.instance }})"
description: "{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} receive errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: HostNetworkTransmitErrors
expr: increase(node_network_transmit_errs_total[5m]) > 0
for: 5m
labels:
severity: warning
annotations:
summary: "Host Network Transmit Errors (instance {{ $labels.instance }})"
description: "{{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} transmit errors in the last five minutes.\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- name: ContainerUsage
rules:
- alert: ContainerKilled
expr: time() - container_last_seen{name!~"deploy_tutorial_notebooks|notebookdeploy|autodeploy|deploy_README_ipynb"} > 60
for: 5m
labels:
severity: warning
annotations:
summary: "Container killed (instance {{ $labels.instance }})"
description: "A container has disappeared\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: ContainerCpuUsage
expr: (sum(rate(container_cpu_usage_seconds_total{name=~".+"}[3m])) BY (instance, name) * 100) > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Container CPU usage (instance {{ $labels.instance }})"
description: "Container CPU usage is above 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: ContainerMemoryUsage
expr: (sum(container_memory_usage_bytes{name=~".+"}) BY (instance, name) / sum(container_spec_memory_limit_bytes{name=~".+"} > 0) BY (instance, name) * 100) > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Container Memory usage (instance {{ $labels.instance }})"
description: "Container Memory usage is above 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: ContainerVolumeUsage
expr: (1 - sum(container_fs_inodes_free) BY (instance) / sum(container_fs_inodes_total) BY (instance)) * 100 > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Container Volume usage (instance {{ $labels.instance }})"
description: "Container Volume usage is above 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: ContainerVolumeIoUsage
expr: (sum(container_fs_io_current) BY (instance, name) * 100) > 80
for: 5m
labels:
severity: warning
annotations:
summary: "Container Volume IO usage (instance {{ $labels.instance }})"
description: "Container Volume IO usage is above 80%\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"
- alert: ContainerHighThrottleRate
expr: rate(container_cpu_cfs_throttled_seconds_total[3m]) > 1
for: 5m
labels:
severity: warning
annotations:
summary: "Container high throttle rate (instance {{ $labels.instance }})"
description: "Container is being throttled\n VALUE = {{ $value }}\n LABELS: {{ $labels }}"