forked from dotnet/iot
-
Notifications
You must be signed in to change notification settings - Fork 1
/
OpenHardwareMonitor.cs
1009 lines (888 loc) · 36.2 KB
/
OpenHardwareMonitor.cs
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
// Licensed to the .NET Foundation under one or more agreements.
// The .NET Foundation licenses this file to you under the MIT license.
using System;
using System.Collections;
using System.Collections.Generic;
using System.Diagnostics;
using System.Diagnostics.CodeAnalysis;
using System.IO;
using System.Linq;
using System.Management;
using System.Runtime.CompilerServices;
using System.Runtime.InteropServices;
using System.Text;
using System.Threading;
using UnitsNet;
using UnitsNet.Units;
// We have a check on all constructors to ensure that we throw when not on Windows, so disabling warning on calling windows-only apis.
#pragma warning disable CA1416 // Validate platform compatibility
namespace Iot.Device.HardwareMonitor
{
/// <summary>
/// This class connects to a running instance of OpenHardwareMonitor and reads out all available values.
/// This works only if OpenHardwareMonitor (https://openhardwaremonitor.org/) is currently running.
/// While the tool needs to be run with elevated permissions, the application using this binding does not.
/// </summary>
public sealed class OpenHardwareMonitor : IDisposable
{
/// <summary>
/// This is the monitoring thread interval. All updates will be done in a multiple of this value.
/// </summary>
private static readonly TimeSpan DefaultMonitorInterval = TimeSpan.FromMilliseconds(100);
private static readonly TimeSpan DefaultDerivedSensorsInterval = TimeSpan.FromMilliseconds(500);
private readonly OpenHardwareMonitorTransport _transport;
private readonly string _host;
private readonly int _port;
/// <summary>
/// A delegate that crates an instance of a quantity from a value
/// </summary>
/// <param name="value">Value to convert</param>
/// <returns>A Quantity instance</returns>
public delegate IQuantity UnitCreator(double value);
/// <summary>
/// Event that gets invoked when a value is updated
/// </summary>
/// <param name="sensorToMonitor">Sensor that has an updated value</param>
/// <param name="value">New value for the sensor</param>
/// <param name="timeSinceUpdate">Time since the last update of this sensor</param>
public delegate void OnNewValue(Sensor sensorToMonitor, IQuantity value, TimeSpan timeSinceUpdate);
private static Dictionary<SensorType, (Type Type, UnitCreator Creator)> _typeMap;
private Hardware? _cpu;
private Hardware? _gpu;
private Thread? _monitorThread;
private object _lock;
private List<MonitoringJob> _monitoredElements;
private List<Sensor> _derivedSensors;
private DateTimeOffset _lastMonitorLoop;
private TimeSpan _monitoringInterval;
private IOpenHardwareMonitorInternal? _openHardwareMonitorInternal;
private SensorUpdateStrategy _updateStrategy;
static OpenHardwareMonitor()
{
_typeMap = new Dictionary<SensorType, (Type Type, UnitCreator Creator)>();
_typeMap.Add(SensorType.Temperature, (typeof(Temperature), (x) => Temperature.FromDegreesCelsius(x)));
_typeMap.Add(SensorType.Voltage, (typeof(ElectricPotential), x => ElectricPotential.FromVolts(x)));
_typeMap.Add(SensorType.Load, (typeof(Ratio), x => Ratio.FromPercent(x)));
_typeMap.Add(SensorType.Fan, (typeof(RotationalSpeed), x => RotationalSpeed.FromRevolutionsPerMinute(x)));
_typeMap.Add(SensorType.Flow, (typeof(VolumeFlow), x => VolumeFlow.FromLitersPerHour(x)));
_typeMap.Add(SensorType.Control, (typeof(Ratio), x => Ratio.FromPercent(x)));
_typeMap.Add(SensorType.Level, (typeof(Ratio), x => Ratio.FromPercent(x)));
_typeMap.Add(SensorType.Power, (typeof(Power), x => Power.FromWatts(x)));
_typeMap.Add(SensorType.Clock, (typeof(Frequency), x => Frequency.FromMegahertz(x)));
_typeMap.Add(SensorType.Energy, (typeof(Energy), x => Energy.FromWattHours(x)));
_typeMap.Add(SensorType.HeatFlux, (typeof(HeatFlux), x => HeatFlux.FromKilowattsPerSquareMeter(x)));
_typeMap.Add(SensorType.Current, (typeof(ElectricCurrent), x => ElectricCurrent.FromAmperes(x)));
_typeMap.Add(SensorType.Data, (typeof(Information), x => Information.FromGigabytes(x)));
_typeMap.Add(SensorType.RawValue, (typeof(Ratio), x => Ratio.FromDecimalFractions(x)));
_typeMap.Add(SensorType.Throughput, (typeof(BitRate), x => BitRate.FromMegabytesPerSecond(x)));
_typeMap.Add(SensorType.TimeSpan, (typeof(Duration), x => Duration.FromSeconds(x)));
}
/// <summary>
/// Constructs a new instance of this class.
/// The class can be constructed even if no sensors are available or OpenHardwareMonitor is not running (yet).
/// </summary>
/// <exception cref="PlatformNotSupportedException">The operating system is not Windows.</exception>
public OpenHardwareMonitor()
: this(OpenHardwareMonitorTransport.Auto)
{
}
/// <summary>
/// Constructs a new instance of this class using a specific transport protocol
/// The class can be constructed even if no sensors are available or OpenHardwareMonitor is not running (yet).
/// </summary>
/// <param name="transport">The transport protocol to use. WMI is for OpenHardwareMonitor 0.9 and below, from OpenHardwareMonitor 0.10 and above,
/// HTTP is used.</param>
/// <param name="host">Optional host name for connection</param>
/// <param name="port">Network port</param>
/// <exception cref="PlatformNotSupportedException"></exception>
public OpenHardwareMonitor(OpenHardwareMonitorTransport transport, string host = "localhost", int port = 8086)
{
_transport = transport;
_host = host;
_port = port;
if (!RuntimeInformation.IsOSPlatform(OSPlatform.Windows))
{
throw new PlatformNotSupportedException("This class is only supported on Windows operating systems");
}
_derivedSensors = new List<Sensor>();
_monitorThread = null;
_lock = new object();
_monitoredElements = new List<MonitoringJob>();
_lastMonitorLoop = DateTimeOffset.UtcNow;
MonitoringInterval = DefaultMonitorInterval;
TryConnectToOhm();
}
/// <summary>
/// Selects the sensor update strategy.
/// Default is <see cref="SensorUpdateStrategy.PerSensor"/> for WMI, <see cref="SensorUpdateStrategy.SynchronousAfterTimeout"/> for HTTP.
/// </summary>
public SensorUpdateStrategy UpdateStrategy
{
get
{
return _updateStrategy;
}
set
{
_updateStrategy = value;
if (_openHardwareMonitorInternal != null)
{
_openHardwareMonitorInternal.UpdateStrategy = value;
}
}
}
/// <summary>
/// Re-reads the sensor tree. Updates all values and the list of sensors.
/// You should invalidate all cached <see cref="Sensor"/> and <see cref="Hardware"/> instances after using this with <paramref name="refreshSensorList"/>=true
/// </summary>
/// <paramref name="refreshSensorList">True to also update the list of sensors. False to only update the values. If false, new sensors will not be visible
/// (e.g. after inserting a thumb drive)</paramref>
public void UpdateSensors(bool refreshSensorList)
{
if (_openHardwareMonitorInternal != null)
{
_openHardwareMonitorInternal.UpdateSensors(refreshSensorList);
ExtractCpuNode(_openHardwareMonitorInternal);
}
}
private bool TryConnectToOhm()
{
if (_openHardwareMonitorInternal != null)
{
return true;
}
IOpenHardwareMonitorInternal? monitor = null;
if (_transport == OpenHardwareMonitorTransport.Wmi)
{
monitor = new OpenHardwareMonitorWmi();
UpdateStrategy = SensorUpdateStrategy.PerSensor;
}
else if (_transport == OpenHardwareMonitorTransport.Http)
{
monitor = new OpenHardwareMonitorHttp(_host, _port);
UpdateStrategy = SensorUpdateStrategy.SynchronousAfterTimeout;
}
else if (_transport == OpenHardwareMonitorTransport.Auto)
{
monitor = new OpenHardwareMonitorWmi();
UpdateStrategy = SensorUpdateStrategy.PerSensor;
if (!monitor.HasHardware())
{
monitor.Dispose();
monitor = new OpenHardwareMonitorHttp(_host, _port);
UpdateStrategy = SensorUpdateStrategy.SynchronousAfterTimeout;
}
if (!monitor.HasHardware())
{
monitor.Dispose();
monitor = null;
}
}
else
{
throw new ArgumentException("Unsupported transport protocol selected");
}
if (monitor != null)
{
monitor.UpdateInterval = MonitoringInterval;
monitor.UpdateStrategy = UpdateStrategy;
ExtractCpuNode(monitor);
if (_cpu == null && _gpu == null)
{
monitor.Dispose();
monitor = null;
}
}
_openHardwareMonitorInternal = monitor;
return _openHardwareMonitorInternal != null;
}
private void ExtractCpuNode(IOpenHardwareMonitorInternal monitor)
{
Hardware? newCpu = null;
Hardware? newGpu = null;
foreach (var hardware in monitor.GetHardwareComponents())
{
if (hardware.Type != null && hardware.Type.Equals("CPU", StringComparison.OrdinalIgnoreCase))
{
newCpu = hardware;
}
else if (hardware.Type != null && hardware.Type.StartsWith("GPU", StringComparison.OrdinalIgnoreCase))
{
newGpu = hardware;
}
}
_cpu = newCpu;
_gpu = newGpu;
}
/// <summary>
/// The minimum monitoring interval.
/// </summary>
public TimeSpan MonitoringInterval
{
get
{
return _monitoringInterval;
}
set
{
if (_monitorThread != null)
{
throw new InvalidOperationException($"{nameof(MonitoringInterval)} can only be changed while monitoring is disabled.");
}
if (value <= TimeSpan.Zero)
{
throw new ArgumentOutOfRangeException(nameof(MonitoringInterval));
}
_monitoringInterval = value;
if (_openHardwareMonitorInternal != null)
{
_openHardwareMonitorInternal.UpdateInterval = value;
}
}
}
/// <summary>
/// Number of logical processors in the system
/// </summary>
public int LogicalProcessors
{
get
{
return Environment.ProcessorCount;
}
}
/// <summary>
/// Query the list of all available sensors.
/// </summary>
/// <returns>A list of <see cref="Sensor"/> instances. May be empty.</returns>
/// <exception cref="ManagementException">The WMI objects required are not available. Is OpenHardwareMonitor running?</exception>
public IList<Sensor> GetSensorList()
{
TryConnectToOhm();
List<Sensor> ret = new List<Sensor>();
if (_openHardwareMonitorInternal != null)
{
ret.AddRange(_openHardwareMonitorInternal.GetSensorList());
}
ret.AddRange(_derivedSensors);
return ret;
}
/// <summary>
/// Returns a list of hardware components, such as "CPU", "GPU" or "Mainboard"
/// </summary>
public IList<Hardware> GetHardwareComponents()
{
TryConnectToOhm();
if (_openHardwareMonitorInternal != null)
{
return _openHardwareMonitorInternal.GetHardwareComponents();
}
return new List<Hardware>();
}
/// <summary>
/// Get the list of sensors for a specific piece of hardware
/// </summary>
/// <param name="forHardware">The module that should be queried</param>
/// <returns>A list of sensors</returns>
public IEnumerable<Sensor> GetSensorList(Hardware? forHardware)
{
if (forHardware == null)
{
throw new ArgumentNullException(nameof(forHardware));
}
TryConnectToOhm();
return GetSensorList().Where(x => x.Identifier != null && x.Identifier.StartsWith(forHardware.Identifier ?? string.Empty)).OrderBy(y => y.Identifier);
}
// Some well-known properties have their own method
/// <summary>
/// Gets the average CPU temperature (averaged over all CPU sensors / cores)
/// </summary>
public bool TryGetAverageCpuTemperature(out Temperature temperature)
{
temperature = default;
if (TryConnectToOhm() == false)
{
return false;
}
if (_cpu == null)
{
return false;
}
if (TryGetAverage(_cpu, out temperature))
{
return true;
}
return false;
}
/// <summary>
/// Gets the average GPU temperature (averaged over all GPU sensors / cores)
/// </summary>
/// <param name="temperature">The average GPU temperature</param>
public bool TryGetAverageGpuTemperature(out Temperature temperature)
{
temperature = default;
if (TryConnectToOhm() == false)
{
return false;
}
if (_gpu == null)
{
return false;
}
if (TryGetAverage(_gpu, out temperature))
{
return true;
}
return false;
}
/// <summary>
/// Gets the overall CPU Load
/// </summary>
public Ratio GetCpuLoad()
{
foreach (var s in GetSensorList(_cpu).OrderBy(x => x.Identifier))
{
if (s.SensorType == SensorType.Load && s.TryGetValue(out Ratio load))
{
return load;
}
}
return default(Ratio);
}
/// <summary>
/// Tries to calculate the average of a set of sensors.
/// </summary>
/// <typeparam name="T">Type of value to query (i.e. Load, Power)</typeparam>
/// <param name="hardware">The hardware type (i.e. CPU)</param>
/// <param name="average">Gets the returned quantity</param>
/// <returns>True if at least one matching quantity was found</returns>
/// <exception cref="NotSupportedException">There were multiple sensors found, but they return different units (i.e. CPU temperature is
/// reported as Celsius for some cores and Fahrenheit for others)</exception>
public bool TryGetAverage<T>(Hardware hardware,
#if NET5_0_OR_GREATER
[NotNullWhen(true)]
#endif
out T? average)
where T : IQuantity
{
double value = 0;
int count = 0;
Enum? unitThatWasUsed = null;
foreach (var s in GetSensorList(hardware))
{
if (s.TryGetValue(out T? singleValue))
{
if (unitThatWasUsed == null)
{
unitThatWasUsed = singleValue!.Unit;
}
else if (!unitThatWasUsed.Equals(singleValue!.Unit))
{
throw new NotSupportedException($"The different sensors for {hardware.Name} deliver values in different units");
}
value += (double)singleValue!.Value;
count++;
}
}
if (count == 0)
{
average = default(T);
return false;
}
value = value / count;
average = (T)Quantity.From(value, unitThatWasUsed!);
return true;
}
/// <summary>
/// Starts monitoring a sensor.
/// This will internally start a thread that calls the provided action each time the TimeSpan elapses.
/// </summary>
/// <param name="sensorToMonitor">The sensor to monitor. The same sensor may be registered multiple times</param>
/// <param name="monitoringInterval">The monitoring interval. Will be rounded to the next 0.1s.</param>
/// <param name="onNewValue">Action to perform each time</param>
/// <returns>An identifier for the monitoring job</returns>
public MonitoringJob StartMonitoring(Sensor sensorToMonitor, TimeSpan monitoringInterval, OnNewValue onNewValue)
{
if (sensorToMonitor == null)
{
throw new ArgumentNullException(nameof(sensorToMonitor));
}
if (onNewValue == null)
{
throw new ArgumentNullException(nameof(onNewValue));
}
if (_monitorThread == null || _monitorThread.IsAlive == false)
{
_monitorThread = new Thread(MonitorThread);
_monitorThread.IsBackground = true;
_monitorThread.Start();
}
double roundedInterval = monitoringInterval.TotalSeconds;
// round to the nearest multiple of the thread interval
double fract = roundedInterval % MonitoringInterval.TotalSeconds;
if (fract > 0)
{
// If fract is > 0, step to the next multiple (+ make sure we're really greater)
roundedInterval = roundedInterval - fract + MonitoringInterval.TotalSeconds + 1E-6;
}
if (roundedInterval < MonitoringInterval.TotalSeconds)
{
roundedInterval = MonitoringInterval.TotalSeconds;
}
monitoringInterval = TimeSpan.FromSeconds(roundedInterval);
lock (_lock)
{
MonitoringJob job = new MonitoringJob(sensorToMonitor, monitoringInterval, onNewValue);
_monitoredElements.Add(job);
return job;
}
}
/// <summary>
/// Stops monitoring of the given job.
/// </summary>
/// <param name="job">Monitoring job</param>
public void StopMonitoring(MonitoringJob job)
{
if (job == null)
{
throw new ArgumentNullException(nameof(job));
}
lock (_lock)
{
_monitoredElements.Remove(job);
}
}
/// <summary>
/// Stops all monitoring.
/// </summary>
public void StopAllMonitoring()
{
lock (_lock)
{
_monitoredElements.Clear();
}
if (_monitorThread != null)
{
_monitorThread.Join();
_monitorThread = null;
}
}
private void MonitorThread()
{
// Stops the thread when the list of monitored elements becomes empty
bool running = true;
while (running)
{
lock (_lock)
{
DateTimeOffset now = DateTimeOffset.UtcNow;
if (_lastMonitorLoop < now - TimeSpan.FromMinutes(5))
{
// We were apparently in sleep mode - skip this loop, because it will falsify results
// (i.e. integrating power usage over a time where the computer was off will be incorrect)
foreach (var elem in _monitoredElements)
{
elem.LastUpdated = now;
}
_lastMonitorLoop = now;
continue;
}
foreach (var elem in _monitoredElements)
{
TimeSpan timeSinceLastUpdate = now - elem.LastUpdated;
if (timeSinceLastUpdate > elem.Interval)
{
if (elem.Sensor.TryGetValue(out IQuantity? value))
{
#if !NET5_0_OR_GREATER
elem.OnNewValue(elem.Sensor, value!, timeSinceLastUpdate);
#else
elem.OnNewValue(elem.Sensor, value, timeSinceLastUpdate);
#endif
}
elem.LastUpdated = now;
}
}
_lastMonitorLoop = now;
running = _monitoredElements.Count > 0;
}
if (running)
{
Thread.Sleep(MonitoringInterval);
}
}
}
/// <summary>
/// Adds some special derived sensors.
/// - For each power sensor, this adds another sensor that integrates power over time and so generated the energy used in W/h or
/// more conveniently, Kilowatthours (this is the unit the electricity bill bases on)
/// - Gives the heat flux for the primary CPU, using the given CPU die size (or a default value)
/// </summary>
/// <param name="cpuDieSize">Die size of your CPU, optional. Find your CPU on https://en.wikichip.org/ to find out. Note: This
/// value is usually much smaller than the size of the physical CPU.</param>
/// <param name="monitoringInterval">Monitoring interval for the derived sensors. Defaults to 500ms.</param>
/// <exception cref="ArgumentOutOfRangeException"><paramref name="monitoringInterval"/> is less than 0.</exception>
public void EnableDerivedSensors(Area cpuDieSize = default, TimeSpan monitoringInterval = default)
{
if (cpuDieSize.Equals(Area.Zero, 0, ComparisonType.Absolute))
{
// Values for some recent intel chips (coffee lake)
if (LogicalProcessors <= 4)
{
cpuDieSize = Area.FromSquareMillimeters(126);
}
else
{
cpuDieSize = Area.FromSquareMillimeters(149.6);
}
}
if (_derivedSensors.Count != 0)
{
// Already set up
return;
}
Sensor? cpuPower = null;
TimeSpan interval = monitoringInterval;
if (interval == default)
{
interval = DefaultDerivedSensorsInterval;
}
else if (interval.TotalSeconds < 0)
{
throw new ArgumentOutOfRangeException(nameof(monitoringInterval));
}
foreach (var sensor in GetSensorList())
{
if (sensor.SensorType == SensorType.Power)
{
// Energy usage (integration of power over time)
Sensor newSensor = new Sensor(sensor.Name + " Energy", sensor.Identifier + "/energy", sensor.Identifier, SensorType.Energy);
// This lambda is a bit confusing: But we add a monitoring for the sensor we derive from and update the new
newSensor.Job = StartMonitoring(sensor, interval, (s, value, timeSinceUpdate) =>
{
double previousEnergy = newSensor.Value;
// Value is in watts, so increment is in watts-hours, which is an unit we can later convert from
double increment = (double)value.Value * timeSinceUpdate.TotalHours;
double newEnergy = previousEnergy + increment;
newSensor.Value = newEnergy;
});
_derivedSensors.Add(newSensor);
}
// For CPU package, calculate heat flux
if (sensor.SensorType == SensorType.Power && sensor.Name != null && sensor.Name.IndexOf("CPU Package", StringComparison.OrdinalIgnoreCase) >= 0)
{
var newSensor = new Sensor(sensor.Name + " HeatFlux", sensor.Identifier + "/heatflux", sensor.Identifier, SensorType.HeatFlux);
newSensor.Job = StartMonitoring(sensor, interval, (s, value, timeSinceUpdate) =>
{
Power p = Power.FromWatts(value.Value); // Current power usage in Watts
HeatFlux hf = p / cpuDieSize;
newSensor.Value = hf.KilowattsPerSquareMeter;
});
_derivedSensors.Add(newSensor);
cpuPower = sensor;
}
}
Sensor? vcore = GetSensorList().FirstOrDefault(x => x.SensorType == SensorType.Voltage && x.Name != null && x.Name.IndexOf("CPU VCore", StringComparison.OrdinalIgnoreCase) >= 0);
// From VCore and CPU package power calculate amperes into CPU
if (cpuPower != null && vcore != null)
{
var newSensor = new Sensor(vcore.Name + " Current", vcore.Identifier + "/current", vcore.Identifier, SensorType.Current);
newSensor.Job = StartMonitoring(vcore, interval, (s, value, timeSinceUpdate) =>
{
if (cpuPower.TryGetValue(out Power power))
{
ElectricPotential potential = ElectricPotential.FromVolts(value.Value);
if (potential.Volts > 0)
{
ElectricCurrent current = power / potential;
s.Value = current.Amperes;
}
else
{
s.Value = 0;
}
}
});
_derivedSensors.Add(newSensor);
}
}
/// <summary>
/// Remove the derived sensors from the active list.
/// </summary>
public void DisableDerivedSensors()
{
foreach (var s in _derivedSensors)
{
if (s.Job is object)
{
StopMonitoring(s.Job);
}
s.Dispose();
}
_derivedSensors.Clear();
}
/// <inheritdoc/>
public void Dispose()
{
StopAllMonitoring();
if (_openHardwareMonitorInternal != null)
{
_openHardwareMonitorInternal.Dispose();
_openHardwareMonitorInternal = null;
}
_gpu = null;
_cpu = null;
}
/// <summary>
/// Represents a single sensor
/// </summary>
public class Sensor : IDisposable
{
private readonly string _name;
private readonly string _identifier;
private readonly string? _parent;
private readonly SensorType _sensorType;
private MonitoringJob? _job;
private double _value;
/// <summary>
/// Create a sensor instance from a management object.
/// This member is obsolete, use another constructor instead or a derived class.
/// </summary>
[Obsolete("Use Sensor(string name, string identifier, string? parent, SensorType typeEnum) instead")]
public Sensor(ManagementObject dummy, string name, string identifier, string? parent, SensorType typeEnum)
{
_name = name;
_identifier = identifier;
_parent = parent;
_sensorType = typeEnum;
}
/// <summary>
/// Creates a sensor instance
/// </summary>
public Sensor(string name, string identifier, string? parent, SensorType typeEnum)
{
_name = name;
_identifier = identifier;
_parent = parent;
_sensorType = typeEnum;
}
/// <summary>
/// Name of the sensor
/// </summary>
public string Name => _name;
/// <summary>
/// Sensor identifier (device path)
/// </summary>
public string Identifier => _identifier;
/// <summary>
/// Sensor parent
/// </summary>
public string? Parent => _parent;
/// <summary>
/// Sets or gets the last value of the sensor. To get an updated value, use <see cref="TryGetValue"/> instead.
/// The setter is intended for implementations of derived sensors only.
/// </summary>
public double Value
{
get
{
return _value;
}
set
{
_value = value;
}
}
/// <summary>
/// Kind of sensor
/// </summary>
public SensorType SensorType => _sensorType;
/// <summary>
/// Job associated with updating this value
/// </summary>
internal MonitoringJob? Job
{
get => _job;
set => _job = value;
}
/// <summary>
/// Attempt to query a value for the sensor
/// </summary>
/// <param name="value">Returned value</param>
/// <returns>True if a value was available</returns>
public bool TryGetValue(
#if NET5_0_OR_GREATER
[NotNullWhen(true)]
#endif
out IQuantity? value)
{
if (!_typeMap.TryGetValue(SensorType, out var elem))
{
value = null;
return false;
}
if (!UpdateValue(out double realValue))
{
value = null;
return false;
}
Value = realValue;
IQuantity newValueAsUnitInstance = elem.Creator(realValue);
value = newValueAsUnitInstance;
return true;
}
/// <summary>
/// Read the value from the underlying transport. This is expected to be overridden by derived classes, unless they use
/// <see cref="Value"/> to set the content.
/// </summary>
protected virtual bool UpdateValue(out double value)
{
value = _value;
return true;
}
/// <summary>
/// Attempt to get a value of the provided type
/// </summary>
/// <typeparam name="T">The type of the quantity to return</typeparam>
/// <param name="value">The returned value</param>
/// <returns>True if a value of type T could be retrieved</returns>
public bool TryGetValue<T>(
#if NET5_0_OR_GREATER
[NotNullWhen(true)]
#endif
out T? value)
where T : IQuantity
{
if (!_typeMap.TryGetValue(SensorType, out var elem))
{
value = default(T);
return false;
}
if (typeof(T) != elem.Type)
{
value = default(T);
return false;
}
UpdateValue(out double newValue);
Value = newValue;
object newValueAsUnitInstance = elem.Creator(newValue);
value = (T)newValueAsUnitInstance;
return true;
}
/// <inheritdoc />
public override string? ToString()
{
return Name ?? base.ToString();
}
/// <summary>
/// Disposes this instance
/// </summary>
protected virtual void Dispose(bool disposing)
{
// nothing to do
}
/// <inheritdoc/>
public void Dispose()
{
Dispose(true);
GC.SuppressFinalize(this);
}
}
/// <summary>
/// Represents a piece of hardware
/// </summary>
public sealed class Hardware
{
private readonly string _name;
private readonly string _identifier;
private readonly string? _parent;
private readonly string? _type;
/// <summary>
/// Create an instance of this class
/// </summary>
public Hardware(string name, string identifier, string? parent, string? type)
{
_name = name;
_identifier = identifier;
_parent = parent;
_type = type;
}
/// <summary>
/// Name of the object
/// </summary>
public string Name => _name;
/// <summary>
/// Device path
/// </summary>
public string Identifier => _identifier;
/// <summary>
/// Parent in device path
/// </summary>
public string? Parent => _parent;
/// <summary>
/// Type of resource
/// </summary>
public string? Type => _type;
/// <summary>
/// Name of this instance
/// </summary>
public override string? ToString()
{
return Name ?? base.ToString();
}
}
/// <summary>
/// A job that monitors a particular sensor
/// </summary>
public sealed class MonitoringJob
{
private readonly Sensor _sensor;
private readonly TimeSpan _interval;
private readonly OnNewValue _onNewValue;
private DateTimeOffset _lastUpdated;
internal MonitoringJob(Sensor sensor, TimeSpan timeSpan, OnNewValue onNewValue)
{
_sensor = sensor;
_interval = timeSpan;
_onNewValue = onNewValue;
LastUpdated = DateTimeOffset.UtcNow;
}
/// <summary>
/// Sensor this job operates on
/// </summary>
public Sensor Sensor => _sensor;
/// <summary>
/// Update interval
/// </summary>
public TimeSpan Interval => _interval;
internal OnNewValue OnNewValue => _onNewValue;
internal DateTimeOffset LastUpdated
{
get => _lastUpdated;
set => _lastUpdated = value;
}
}
private sealed class EnergyManagementInstance : ManagementObject
{
// Current value, high precision
private double _value;
public EnergyManagementInstance()
{
_value = 0;
Properties.Add("Value", 0.0f);
}
public double Value
{
get
{
return _value;
}
set
{