-
Notifications
You must be signed in to change notification settings - Fork 15
/
Copy pathcsm-1.8.0-values.template
472 lines (447 loc) · 15.4 KB
/
csm-1.8.0-values.template
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
## K8S/DRIVER ATTRIBUTES
##########################################
## K8S/CSI-PowerStore ATTRIBUTES
##########################################
csi-powerstore:
enabled: $POWERSTORE_ENABLED
version: v2.8.0
images:
driverRepository: $IMAGE_REPOSITORY
## Controller ATTRIBUTES
controller:
controllerCount: $CONTROLLER_COUNT
volumeNamePrefix: $VOLUME_NAME_PREFIX
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $CONTROLLER_POD_NODE_SELECTOR
tolerations: $CONTROLLER_TOLERATIONS
replication:
enabled: $REPLICATION_ENABLED
image: dellemc/dell-csi-replicator:v1.6.0
vgsnapshot:
enabled: $VG_SNAPSHOT_ENABLED
image: dellemc/csi-volumegroup-snapshotter:v1.3.0
metadataretriever: dellemc/csi-metadata-retriever:v1.5.0
snapshot:
enabled: $SNAPSHOT_ENABLED
snapNamePrefix: $SNAP_NAME_PREFIX
resizer:
enabled: $RESIZER_ENABLED
## Node ATTRIBUTES
node:
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $NODE_POD_NODE_SELECTOR
tolerations: $NODE_TOLERATIONS
# Uncomment if CSM for Resiliency and CSI Driver pods monitor are enabled
# - key: "offline.vxflexos.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "vxflexos.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.unity.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "unity.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.isilon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "isilon.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.powerstore.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "powerstore.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
podmon:
enabled: $RESILIENCY_ENABLED
image: dellemc/podmon:v1.7.0
controller:
args:
- "--csisock=unix:/var/run/csi/csi.sock"
- "--labelvalue=csi-powerstore"
- "--arrayConnectivityPollRate=60"
- "--driverPath=csi-powerstore.dellemc.com"
- "--mode=controller"
- "--skipArrayConnectionValidation=false"
- "--driver-config-params=/powerstore-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
node:
args:
- "--csisock=unix:/var/lib/kubelet/plugins/csi-powerstore.dellemc.com/csi_sock"
- "--labelvalue=csi-powerstore"
- "--arrayConnectivityPollRate=60"
- "--driverPath=csi-powerstore.dellemc.com"
- "--mode=node"
- "--leaderelection=false"
- "--driver-config-params=/powerstore-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
maxPowerstoreVolumesPerNode: $MAX_VOLUMES_PER_NODE
## K8S/CSI-PowerMax ATTRIBUTES
##########################################
csi-powermax:
enabled: $POWERMAX_ENABLED
global:
storageArrays:
- storageArrayId: "$POWERMAX_STORAGE_ARRAY_ID"
endpoint: $POWERMAX_STORAGE_ARRAY_ENDPOINT_URL
backupEndpoint: $POWERMAX_STORAGE_ARRAY_BACKUP_ENDPOINT_URL
- storageArrayId: "$TARGET_ARRAY_ID"
endpoint: $TARGET_UNISPHERE
managementServers:
- endpoint: $POWERMAX_MANAGEMENT_SERVERS_ENDPOINT_URL
- endpoint: $TARGET_UNISPHERE
version: v2.8.0
images:
driverRepository: $IMAGE_REPOSITORY
clusterPrefix: $POWERMAX_CLUSTER_PREFIX
portGroups: "$POWERMAX_PORT_GROUPS"
fsGroupPolicy: "$FSGROUP_POLICY"
maxPowerMaxVolumesPerNode: $MAX_VOLUMES_PER_NODE
enableCHAP: $ISCSI_CHAP_ENABLED
transportProtocol: "$NODE_TRANSPORT_PROTOCOL"
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
controller:
controllerCount: $CONTROLLER_COUNT
volumeNamePrefix: $VOLUME_NAME_PREFIX
snapshot:
enabled: $SNAPSHOT_ENABLED
snapNamePrefix: $SNAP_NAME_PREFIX
resizer:
enabled: $RESIZER_ENABLED
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $CONTROLLER_POD_NODE_SELECTOR
tolerations: $CONTROLLER_TOLERATIONS
node:
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
topologyControl:
enabled: $TOPOLOGY_ENABLED
nodeSelector: $NODE_POD_NODE_SELECTOR
tolerations: $NODE_TOLERATIONS
- key: "node.kubernetes.io/memory-pressure"
operator: "Exists"
effect: "NoExecute"
- key: "node.kubernetes.io/disk-pressure"
operator: "Exists"
effect: "NoExecute"
- key: "node.kubernetes.io/network-unavailable"
operator: "Exists"
effect: "NoExecute"
csireverseproxy:
image: dellemc/csipowermax-reverseproxy:v2.7.0
deployAsSidecar: true
replication:
enabled: $REPLICATION_ENABLED
image: dellemc/dell-csi-replicator:v1.6.0
migration:
enabled: $MIGRATION_ENABLED
image: dellemc/dell-csi-migrator:v1.2.0
nodeRescanSidecarImage: dellemc/dell-csi-node-rescanner:v1.1.0
authorization:
enabled: $AUTHORIZATION_ENABLED
sidecarProxyImage: dellemc/csm-authorization-sidecar:v1.8.0
proxyHost: $AUTHORIZATION_PROXY_HOST
skipCertificateValidation: $AUTHORIZATION_SKIP_CERTIFICATE_VALIDATION
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
vSphere:
enabled: $VSPHERE_ENABLED
fcPortGroup: "$VSPHERE_FC_PORT_GROUP"
fcHostName: "$VSPHERE_FC_HOST_NAME"
vCenterHost: "$VSPHERE_VCENTER_HOST"
vCenterCredSecret: $VSPHERE_VCENTER_CRED_SECRET
## K8S/CSI-PowerFlex ATTRIBUTES
##########################################
csi-vxflexos:
enabled: $POWERFLEX_ENABLED
version: v2.8.0
images:
driverRepository: $IMAGE_REPOSITORY
powerflexSdc: dellemc/sdc:3.6.1
certSecretCount: $CERT_SECRET_COUNT
controller:
replication:
enabled: $REPLICATION_ENABLED
image: dellemc/dell-csi-replicator:v1.6.0
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
controllerCount: $CONTROLLER_COUNT
volumeNamePrefix: $VOLUME_NAME_PREFIX
snapshot:
enabled: $SNAPSHOT_ENABLED
resizer:
enabled: $RESIZER_ENABLED
nodeSelector: $CONTROLLER_POD_NODE_SELECTOR
tolerations: $CONTROLLER_TOLERATIONS
node:
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $NODE_POD_NODE_SELECTOR
renameSDC:
enabled: $RENAME_SDC_ENABLED
sdcPrefix: $SDC_PREFIX
approveSDC:
enabled: $APPROVE_SDC_ENABLED
tolerations: $NODE_TOLERATIONS
# Uncomment if CSM for Resiliency and CSI Driver pods monitor is enabled
# - key: "offline.vxflexos.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "vxflexos.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.unity.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "unity.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.isilon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "isilon.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
enableQuota: $QUOTA_ENABLED
monitor:
enabled: $MONITOR_ENABLED
vgsnapshotter:
enabled: $VG_SNAPSHOT_ENABLED
image: dellemc/csi-volumegroup-snapshotter:v1.3.0
podmon:
enabled: $RESILIENCY_ENABLED
image: dellemc/podmon:v1.7.0
controller:
args:
- "--csisock=unix:/var/run/csi/csi.sock"
- "--labelvalue=csi-vxflexos"
- "--mode=controller"
- "--skipArrayConnectionValidation=false"
- "--driver-config-params=/vxflexos-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
node:
args:
- "--csisock=unix:/var/lib/kubelet/plugins/vxflexos.emc.dell.com/csi_sock"
- "--labelvalue=csi-vxflexos"
- "--mode=node"
- "--leaderelection=false"
- "--driver-config-params=/vxflexos-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
authorization:
enabled: $AUTHORIZATION_ENABLED
sidecarProxyImage: dellemc/csm-authorization-sidecar:v1.8.0
proxyHost: $AUTHORIZATION_PROXY_HOST
skipCertificateValidation: $AUTHORIZATION_SKIP_CERTIFICATE_VALIDATION
maxPowerflexVolumesPerNode: $MAX_VOLUMES_PER_NODE
## K8S/CSI-PowerScale ATTRIBUTES
##########################################
csi-isilon:
enabled: $POWERSCALE_ENABLED
version: "v2.8.0"
images:
driverRepository: $IMAGE_REPOSITORY
certSecretCount: $CERT_SECRET_COUNT
allowedNetworks: []
verbose: 1
enableCustomTopology: false
fsGroupPolicy: $FSGROUP_POLICY
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
maxIsilonVolumesPerNode: $MAX_VOLUMES_PER_NODE
controller:
controllerCount: $CONTROLLER_COUNT
volumeNamePrefix: $VOLUME_NAME_PREFIX
replication:
enabled: $REPLICATION_ENABLED
image: dellemc/dell-csi-replicator:v1.6.0
snapshot:
enabled: $SNAPSHOT_ENABLED
snapNamePrefix: $SNAP_NAME_PREFIX
resizer:
enabled: $RESIZER_ENABLED
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $CONTROLLER_POD_NODE_SELECTOR
tolerations: $CONTROLLER_TOLERATIONS
node:
nodeSelector: $NODE_POD_NODE_SELECTOR
tolerations: $NODE_TOLERATIONS
# - key: "node.kubernetes.io/memory-pressure"
# operator: "Exists"
# effect: "NoExecute"
# - key: "node.kubernetes.io/disk-pressure"
# operator: "Exists"
# effect: "NoExecute"
# - key: "node.kubernetes.io/network-unavailable"
# operator: "Exists"
# effect: "NoExecute"
# Uncomment if CSM for Resiliency and CSI Driver pods monitor are enabled
# - key: "offline.vxflexos.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "vxflexos.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.unity.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "unity.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.isilon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "isilon.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
authorization:
enabled: $AUTHORIZATION_ENABLED
sidecarProxyImage: dellemc/csm-authorization-sidecar:v1.8.0
proxyHost: $AUTHORIZATION_PROXY_HOST
skipCertificateValidation: $AUTHORIZATION_SKIP_CERTIFICATE_VALIDATION
# Enable this feature only after contact support for additional information
podmon:
enabled: $RESILIENCY_ENABLED
image: dellemc/podmon:v1.7.0
controller:
args:
- "--csisock=unix:/var/run/csi/csi.sock"
- "--labelvalue=csi-isilon"
- "--arrayConnectivityPollRate=60"
- "--driverPath=csi-isilon.dellemc.com"
- "--mode=controller"
- "--skipArrayConnectionValidation=false"
- "--driver-config-params=/csi-isilon-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
node:
args:
- "--csisock=unix:/var/lib/kubelet/plugins/csi-isilon/csi_sock"
- "--labelvalue=csi-isilon"
- "--arrayConnectivityPollRate=60"
- "--driverPath=csi-isilon.dellemc.com"
- "--mode=node"
- "--leaderelection=false"
- "--driver-config-params=/csi-isilon-config-params/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
## K8S/CSI-Unity ATTRIBUTES
##########################################
csi-unity:
enabled: $UNITY_ENABLED
version: v2.8.0
images:
driverRepository: $IMAGE_REPOSITORY
certSecretCount: $CERT_SECRET_COUNT
fsGroupPolicy: $FSGROUP_POLICY
controller:
controllerCount: $CONTROLLER_COUNT
volumeNamePrefix: $VOLUME_NAME_PREFIX
snapshot:
enabled: $SNAPSHOT_ENABLED
snapNamePrefix: $SNAP_NAME_PREFIX
resizer:
enabled: $RESIZER_ENABLED
nodeSelector: $CONTROLLER_POD_NODE_SELECTOR
tolerations: $CONTROLLER_TOLERATIONS
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
node:
healthMonitor:
enabled: $HEALTH_MONITOR_ENABLED
nodeSelector: $NODE_POD_NODE_SELECTOR
tolerations: $NODE_TOLERATIONS
# - key: "node.kubernetes.io/memory-pressure"
# operator: "Exists"
# effect: "NoExecute"
# - key: "node.kubernetes.io/disk-pressure"
# operator: "Exists"
# effect: "NoExecute"
# - key: "node.kubernetes.io/network-unavailable"
# operator: "Exists"
# effect: "NoExecute"
# Uncomment if CSM for Resiliency and CSI Driver pods monitor are enabled
# - key: "offline.vxflexos.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "vxflexos.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.unity.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "unity.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "offline.isilon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
# - key: "isilon.podmon.storage.dell.com"
# operator: "Exists"
# effect: "NoSchedule"
storageCapacity:
enabled: $STORAGE_CAPACITY_ENABLED
maxUnityVolumesPerNode: $MAX_VOLUMES_PER_NODE
podmon:
enabled: $RESILIENCY_ENABLED
image: dellemc/podmon:v1.7.0
controller:
args:
- "--csisock=unix:/var/run/csi/csi.sock"
- "--labelvalue=csi-unity"
- "--driverPath=csi-unity.dellemc.com"
- "--mode=controller"
- "--skipArrayConnectionValidation=false"
- "--driver-config-params=/unity-config/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
node:
args:
- "--csisock=unix:/var/lib/kubelet/plugins/unity.emc.dell.com/csi_sock"
- "--labelvalue=csi-unity"
- "--driverPath=csi-unity.dellemc.com"
- "--mode=node"
- "--leaderelection=false"
- "--driver-config-params=/unity-config/driver-config-params.yaml"
- "--driverPodLabelValue=dell-storage"
- "--ignoreVolumelessPods=false"
## K8S/Replication Module ATTRIBUTES
##########################################
csm-replication:
enabled: $REPLICATION_ENABLED
## K8S/Observability Module ATTRIBUTES
##########################################
karavi-observability:
enabled: $OBSERVABILITY_ENABLED
karaviMetricsPowerstore:
enabled: $POWERSTORE_OBSERVABILITY_METRICS_ENABLED
karaviMetricsPowermax:
enabled: $POWERMAX_OBSERVABILITY_METRICS_ENABLED
karaviMetricsPowerflex:
enabled: $POWERFLEX_OBSERVABILITY_METRICS_ENABLED
karaviMetricsPowerscale:
enabled: $POWERSCALE_OBSERVABILITY_METRICS_ENABLED
cert-manager:
enabled: $OBSERVABILITY_CERT_MANAGER_ENABLED
## K8S/Cert-manager ATTRIBUTES
##########################################
cert-manager:
enabled: $CERT_MANAGER_ENABLED