LYWSD03MMC HW revision going blank after fw reset #139

Open
slakouz opened this issue Apr 4, 2024 · 2 comments
Open

LYWSD03MMC HW revision going blank after fw reset #139

slakouz opened this issue Apr 4, 2024 · 2 comments

Comments

@slakouz
Copy link

slakouz commented Apr 4, 2024

After revert fw back to original stock fw at https://devbis.github.io/telink-zigbee/ I got an empty HW Revision string. I tried atc1441 and pvvx online flashers and usb-uart with restore original fw 130 -they all restoring fw but HW Revision still empty. MI Home not accepting such device with verification -29 error.
2024-04-04_10-18-38

@slakouz
Copy link
Author

slakouz commented Apr 4, 2024

2024-04-04_11-56-57

@slakouz
Copy link
Author

slakouz commented Apr 4, 2024

Fixed by erase flash via usb-uart then load 130 fw. Mihome successfully paired. Please note MAC has been changed now and HW Rev = 0000. Then at https://pvvx.github.io/ATC_MiThermometer/TelinkMiFlasher.html load ATC 4.7 fw and HW changed now to B1.7. The real HW is 2.0 on PCB