package main
import (
"flag"
"fmt"
"log"
"net/http"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/client_golang/prometheus/promhttp"
)
var (
enphaseAddr = flag.String("enphase_addr", "", "IP address of Enphase Envoy")
port = flag.Int("port", 0, "port to run on")
)
// enphaseCollector implements prometheus.Collector.
type enphaseCollector struct {
addr string
up, genNow, genToday, genLifetime prometheus.Gauge
}
func newEnphaseCollector(addr string) *enphaseCollector {
ec := &enphaseCollector{
addr: addr,
up: prometheus.NewGauge(prometheus.GaugeOpts{
Name: "up",
Help: "Whether the Enphase Envoy is responding",
}),
genNow: prometheus.NewGauge(prometheus.GaugeOpts{
Name: "power_production_watts",
Help: "Power being produced, in W",
}),
genToday: prometheus.NewGauge(prometheus.GaugeOpts{
Name: "energy_today_watthours",
Help: "Energy produced today, in Wh",
}),
// In theory this should always increase, but we can't guarantee it,
// so leave as a gauge instead of a counter. It's only read as snapshots anyway.
genLifetime: prometheus.NewGauge(prometheus.GaugeOpts{
Name: "energy_lifetime_watthours",
Help: "Energy produced in the system's lifetime, in Wh",
}),
}
return ec
}
func (ec *enphaseCollector) Describe(ch chan<- *prometheus.Desc) {
ec.up.Describe(ch)
ec.genNow.Describe(ch)
ec.genToday.Describe(ch)
ec.genLifetime.Describe(ch)
}
func (ec *enphaseCollector) Collect(ch chan<- prometheus.Metric) {
// TODO: rate limit here
// TODO: set a HTTP timeout too. 5s should be plenty.
stats, err := fetchStats(ec.addr)
if err != nil {
ec.up.Set(0)
ec.genNow.Set(0)
ec.genToday.Set(0)
ec.genLifetime.Set(0)
} else {
ec.up.Set(1)
ec.genNow.Set(float64(stats.WattsNow))
ec.genToday.Set(float64(stats.WattHoursToday))
ec.genLifetime.Set(float64(stats.WattHoursLifetime))
//log.Printf("Currently generating %.2f kW", float64(stats.WattsNow)/1e3)
//log.Printf("Generated %.1f kWh today", float64(stats.WattHoursToday)/1e3)
}
ch <- ec.up
ch <- ec.genNow
ch <- ec.genToday
ch <- ec.genLifetime
}
func main() {
flag.Parse()
if *enphaseAddr == "" {
log.Fatal("must provide -enphase_addr")
}
coll := newEnphaseCollector(*enphaseAddr)
prometheus.MustRegister(coll)
http.Handle("/metrics", promhttp.Handler())
log.Fatal(http.ListenAndServe(fmt.Sprintf(":%d", *port), nil))
}