Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathResponseWarning.txt
66 lines (64 loc) · 4.94 KB
/
ResponseWarning.txt
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
# Example
# request = 37 45 11 01 46 B1 00 00 FE F7 0D
# response = 37 45 11 01 46 00 30 49 B1 00 C5 5C 01 01 10 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 04 00 00 00 00 01 00 01 00 00 00 00 00 00 00 00 F6 FB FF FF 55 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 00 01 5E 06 13 D0 BD 54 01 F6 A6 0D
----------------------------------------------------------------------------------------------
Data Name Unit Result Type
----------------------------------------------------------------------------------------------
37 45 head / /
11 ver / 1.1
01 adr / 1
46 cid1 / /
00 RTN / check RTN table
F0 4D length / /
B0 cid2 / check CID table
00 cid3 / check CID table
C5 5C / / /
01 total pack number / 1
------------------------------------
01 #1 pack adr / 1
10 cells number / 16
00 cell1 warning / check Warning Code table
00 cell2 warning / check Warning Code table
00 cell3 warning / check Warning Code table
00 cell4 warning / check Warning Code table
00 cell5 warning / check Warning Code table
00 cell6 warning / check Warning Code table
00 cell7 warning / check Warning Code table
00 cell8 warning / check Warning Code table
00 cell9 warning / check Warning Code table
00 cell10 warning / check Warning Code table
00 cell11 warning / check Warning Code table
00 cell12 warning / check Warning Code table
00 cell13 warning / check Warning Code table
00 cell14 warning / check Warning Code table
00 cell15 warning / check Warning Code table
00 cell16 warning / check Warning Code table
04 NTC number / 4
00 NTC1 warning / check Warning Code table
00 NTC2 warning / check Warning Code table
00 NTC3 warning / check Warning Code table
00 NTC4 warning / check Warning Code table
01 Ambient NTC number / 1
00 Ambient NTC warning / check Warning Code table
01 MOS NTC number / 1
00 MOS NTC warning / check Warning Code table
00 Charge current warning / check Warning Code table
00 Pack voltage warning / check Warning Code table
00 Discharge current warning / check Warning Code table
00 00 00 00 Protection state code / check Warning Code table
F6 FB FF FF Function control code / check Warning Code table
55 00 00 00 Working state code / check Warning Code table
00 00 00 00 Fault state code / check Warning Code table
00 00 00 00 Warning state code / check Warning Code table
00 00 00 00 Cells balance state code / check Warning Code table
00 00 00 00 Cells balance state code / check Warning Code table
01 00 BMS&Inverter State code / check Warning Code table
01 5E Max Charge current 100mA 35000
06 13 Max Discharge current 100mA 155000
D0 BD 54 01 crc32 /
-----------------------------------------
{#2 pack data}
-----------------------------------------
F6 A6 chksum
0D end
------------------------------------------------------------------------------------------------