Notifications
You must be signed in to change notification settings - Fork 5
/
collector.go
313 lines (281 loc) · 14.1 KB
/
collector.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
package main
import (
"net"
log "github.com/sirupsen/logrus"
"github.com/prometheus/client_golang/prometheus"
"github.com/foogod/go-powerwall"
)
type powerwallCollector struct{
pw *powerwall.Client
metrics map[string]*prometheus.Desc
}
func NewPowerwallCollector(client *powerwall.Client) *powerwallCollector {
c := powerwallCollector{
pw: client,
metrics: make(map[string]*prometheus.Desc),
}
c.newDesc("info", "Device Information", []string{"version", "git_hash"})
c.newDesc("uptime_seconds", "Seconds since last reboot", nil)
c.newDesc("commission_count", "Number of config changes since last reboot", nil)
c.newDesc("charge_ratio", "Total amount of charge", nil)
c.newDesc("reserve_ratio", "Amount of charge reserved for backup use", nil)
c.newDesc("operation_mode", "Operational Mode", []string{"mode"})
c.newDesc("sitemaster_running", "Is powerwall in running or stopped state?", nil)
c.newDesc("sitemaster_connected", "Is powerwall connected to Tesla?", nil)
c.newDesc("power_supply_mode", "Is powerwall in 'power supply' mode?", nil)
c.newDesc("sitemaster_busy", "Is sitemaster performing some operation which should not be interrupted by stop/reboot?", []string{"reason"})
c.newDesc("problems_detected_count", "Number of problems currently reported", nil)
// system status
c.newDesc("full_pack_joules", "Total capacity of all batteries", nil)
c.newDesc("remaining_joules", "Remaining charge in all batteries", nil)
c.newDesc("island_state", "Whether powerwall is running in island mode or connected to grid", []string{"state"})
// battery info
c.newDesc("battery_info", "Battery Information", []string{"serial", "partno", "version"})
c.newDesc("battery_full_pack_joules", "Total battery capacity", []string{"serial"})
c.newDesc("battery_remaining_joules", "Remaining charge", []string{"serial"})
c.newDesc("battery_output_volts", "Battery voltage", []string{"serial"})
c.newDesc("battery_output_amps", "Battery current flow (positive is discharging, negative is charging)", []string{"serial"})
c.newDesc("battery_output_hz", "Battery output frequency", []string{"serial"})
c.newDesc("battery_charged_joules_total", "Total amount of energy charged over battery's lifetime", []string{"serial"})
c.newDesc("battery_discharged_joules_total", "Total amount of energy discharged over battery's lifetime", []string{"serial"})
c.newDesc("battery_off_grid", "Is battery disconnected from the grid?", []string{"serial"})
c.newDesc("battery_island_state", "Is battery running in islanded state?", []string{"serial"})
c.newDesc("battery_wobble_detected", "Is frequency wobble detected?", []string{"serial"})
c.newDesc("battery_charge_power_clamped", "Has charging power been clamped?", []string{"serial"})
c.newDesc("battery_backup_ready", "Is battery available for backup use?", []string{"serial"})
c.newDesc("battery_pinv_state", "Battery power inverter state", []string{"serial", "state"})
c.newDesc("battery_pinv_grid_state", "Battery power grid state", []string{"serial", "state"})
c.newDesc("battery_opseq_state", "Battery power grid state", []string{"serial", "state"})
// aggregates
c.newDesc("instant_power_watts", "Instant Power (W)", []string{"category"})
c.newDesc("instant_reactive_power_watts", "Instant Reactive Power (W)", []string{"category"})
c.newDesc("instant_apparent_power_watts", "Instant Apparent Power (W)", []string{"category"})
c.newDesc("frequency_hz", "AC Frequency (Hz)", []string{"category"})
c.newDesc("exported_joules_total", "Energy Exported", []string{"category"}) //TODO: check units
c.newDesc("imported_joules_total", "Energy Imported", []string{"category"}) //TODO: check units
c.newDesc("instant_average_volts", "Instant Average Voltage", []string{"category"})
c.newDesc("instant_average_amps", "Instant Average Current", []string{"category"})
c.newDesc("instant_total_amps", "Instant Total Current", []string{"category"})
// meter devices
c.newDesc("dev_instant_power_watts", "Instant Power (W)", []string{"category", "tyoe", "serial"})
c.newDesc("dev_instant_reactive_power_watts", "Instant Reactive Power (W)", []string{"category", "tyoe", "serial"})
c.newDesc("dev_instant_apparent_power_watts", "Instant Apparent Power (W)", []string{"category", "tyoe", "serial"})
c.newDesc("dev_frequency_hz", "AC Frequency (Hz)", []string{"category", "tyoe", "serial"})
c.newDesc("dev_exported_joules_total", "Energy Exported", []string{"category", "tyoe", "serial"}) //TODO: check units
c.newDesc("dev_imported_joules_total", "Energy Imported", []string{"category", "tyoe", "serial"}) //TODO: check units
c.newDesc("dev_instant_average_volts", "Instant Average Voltage", []string{"category", "tyoe", "serial"})
c.newDesc("dev_instant_average_amps", "Instant Average Current", []string{"category", "tyoe", "serial"})
c.newDesc("dev_instant_total_amps", "Instant Total Current", []string{"category", "tyoe", "serial"})
// network interfaces
c.newDesc("network_enabled", "Is network interface enabled?", []string{"type", "name"})
c.newDesc("network_active", "Is network interface active?", []string{"type", "name"})
c.newDesc("network_primary", "Is this the primary network interface?", []string{"type", "name"})
c.newDesc("network_state", "Current state and reason for last state change", []string{"type", "name", "state", "reason"})
c.newDesc("network_signal_strength", "Wireless signal strength", []string{"type", "name"})
return &c
}
func (c *powerwallCollector) setGaugeBool(ch chan<- prometheus.Metric, name string, value bool, labels ...string) {
v := float64(0)
if value {
v = 1.0
}
c.setGauge64(ch, name, v, labels...)
}
func (c *powerwallCollector) setCounter64(ch chan<- prometheus.Metric, name string, value float64, labels ...string) {
ch <- prometheus.MustNewConstMetric(c.metrics[name], prometheus.CounterValue, value, labels...)
}
func (c *powerwallCollector) setCounter(ch chan<- prometheus.Metric, name string, value float32, labels ...string) {
c.setCounter64(ch, name, float64(value), labels...)
}
func (c *powerwallCollector) Collect(ch chan<- prometheus.Metric) {
log.Debug("Collecting metrics...")
status, err := c.pw.GetStatus()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching status info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGauge(ch, "info", 1, status.Version, status.GitHash)
c.setCounter64(ch, "uptime_seconds", status.UpTime.Seconds())
c.setCounter64(ch, "commission_count", float64(status.CommissionCount))
}
soe, err := c.pw.GetSOE()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching SOE info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGauge(ch, "charge_ratio", soe.Percentage / 100)
}
opdata, err := c.pw.GetOperation()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching operation info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGauge(ch, "operation_mode", 1, opdata.RealMode)
c.setGauge(ch, "reserve_ratio", opdata.BackupReservePercent / 100)
}
sitemaster, err := c.pw.GetSitemaster()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching sitemaster info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGaugeBool(ch, "sitemaster_running", sitemaster.Running)
c.setGaugeBool(ch, "sitemaster_connected", sitemaster.ConnectedToTesla)
c.setGaugeBool(ch, "power_supply_mode", sitemaster.PowerSupplyMode)
if sitemaster.CanReboot != "Yes" {
c.setGauge(ch, "sitemaster_busy", 1, sitemaster.CanReboot)
}
}
problems, err := c.pw.GetProblems()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching troubleshooting problems info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGauge64(ch, "problems_detected_count", float64(len(problems.Problems)))
}
sysstatus, err := c.pw.GetSystemStatus()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching system_status info")
if _, ok := err.(net.Error); ok {
return
}
} else {
c.setGauge(ch, "full_pack_joules", sysstatus.NominalFullPackEnergy * 3600)
c.setGauge(ch, "remaining_joules", sysstatus.NominalEnergyRemaining * 3600)
c.setGauge(ch, "island_state", 1, sysstatus.SystemIslandState)
for _, block := range sysstatus.BatteryBlocks {
serial := block.PackageSerialNumber
c.setGauge(ch, "battery_info", 1, serial, block.PackagePartNumber, block.Version)
c.setGauge(ch, "battery_full_pack_joules", block.NominalFullPackEnergy * 3600, serial)
c.setGauge(ch, "battery_remaining_joules", block.NominalEnergyRemaining * 3600, serial)
c.setGauge(ch, "battery_output_volts", block.VOut, serial)
c.setGauge(ch, "battery_output_amps", block.IOut, serial)
c.setGauge(ch, "battery_output_hz", block.FOut, serial)
c.setGaugeBool(ch, "battery_off_grid", block.OffGrid, serial)
c.setGaugeBool(ch, "battery_island_state", block.VfMode, serial)
c.setGaugeBool(ch, "battery_wobble_detected", block.WobbleDetected, serial)
c.setGaugeBool(ch, "battery_charge_power_clamped", block.ChargePowerClamped, serial)
c.setGaugeBool(ch, "battery_backup_ready", block.BackupReady, serial)
c.setGauge(ch, "battery_pinv_state", 1, serial, block.PinvState)
c.setGauge(ch, "battery_pinv_grid_state", 1, serial, block.PinvGridState)
c.setGauge(ch, "battery_opseq_state", 1, serial, block.OpSeqState)
// In some circumstances, the powerwall can apparently
// report "0" for these stats for some time when
// starting up, etc (but then start showing the correct
// values once it's fully running). This can screw up
// Prometheus by making it think that the counters have
// been reset when they actually haven't, so we just
// don't report these stats if they're showing zero.
if block.EnergyCharged != 0 {
c.setCounter64(ch, "battery_charged_joules_total", float64(block.EnergyCharged) * 3600, serial)
}
if block.EnergyDischarged != 0 {
c.setCounter64(ch, "battery_discharged_joules_total", float64(block.EnergyDischarged) * 3600, serial)
}
}
}
aggs, err := c.pw.GetMetersAggregates()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching meter aggregates info")
if _, ok := err.(net.Error); ok {
return
}
} else {
for cat, data := range *aggs {
c.setGauge(ch, "instant_power_watts", data.InstantPower, cat)
c.setGauge(ch, "instant_reactive_power_watts", data.InstantReactivePower, cat)
c.setGauge(ch, "instant_apparent_power_watts", data.InstantApparentPower, cat)
if data.Frequency != 0 {
c.setGauge(ch, "frequency_hz", data.Frequency, cat)
}
c.setGauge(ch, "instant_average_volts", data.InstantAverageVoltage, cat)
c.setGauge(ch, "instant_average_amps", data.InstantAverageCurrent, cat)
c.setGauge(ch, "instant_total_amps", data.InstantTotalCurrent, cat)
// In some circumstances, the powerwall can apparently
// report "0" for these stats for some time when
// starting up, etc (but then start showing the correct
// values once it's fully running). This can screw up
// Prometheus by making it think that the counters have
// been reset when they actually haven't, so we just
// don't report these stats if they're showing zero.
if data.EnergyExported != 0 {
c.setCounter64(ch, "exported_joules_total", float64(data.EnergyExported) * 3600, cat)
}
if data.EnergyImported != 0 {
c.setCounter64(ch, "imported_joules_total", float64(data.EnergyImported) * 3600, cat)
}
devs, err := c.pw.GetMeters(cat)
if err != nil {
log.WithFields(log.Fields{"cat": cat, "err": err}).Error("Error fetching detailed meter info")
} else {
for _, dev := range *devs {
devtype := dev.Type
serial := dev.Connection.DeviceSerial
data := dev.CachedReadings
c.setGauge(ch, "dev_instant_power_watts", data.InstantPower, cat, devtype, serial)
c.setGauge(ch, "dev_instant_reactive_power_watts", data.InstantReactivePower, cat, devtype, serial)
c.setGauge(ch, "dev_instant_apparent_power_watts", data.InstantApparentPower, cat, devtype, serial)
if data.Frequency != 0 {
c.setGauge(ch, "dev_frequency_hz", data.Frequency, cat, devtype, serial)
}
c.setGauge(ch, "dev_instant_average_volts", data.InstantAverageVoltage, cat, devtype, serial)
c.setGauge(ch, "dev_instant_average_amps", data.InstantAverageCurrent, cat, devtype, serial)
c.setGauge(ch, "dev_instant_total_amps", data.InstantTotalCurrent, cat, devtype, serial)
// (see comment above about exported/imported counters on power-up)
if data.EnergyExported != 0 {
c.setCounter64(ch, "dev_exported_joules_total", float64(data.EnergyExported) * 3600, cat, devtype, serial)
}
if data.EnergyImported != 0 {
c.setCounter64(ch, "dev_imported_joules_total", float64(data.EnergyImported) * 3600, cat, devtype, serial)
}
}
}
}
}
nets, err := c.pw.GetNetworks()
if err != nil {
log.WithFields(log.Fields{"err": err}).Error("Error fetching networks info")
if _, ok := err.(net.Error); ok {
return
}
} else {
for _, net := range *nets {
name := net.NetworkName
nettype := net.Interface
c.setGaugeBool(ch, "network_enabled", net.Enabled, nettype, name)
c.setGaugeBool(ch, "network_active", net.Active, nettype, name)
c.setGaugeBool(ch, "network_primary", net.Primary, nettype, name)
iface := net.IfaceNetworkInfo
if iface.NetworkName != "" {
c.setGauge(ch, "network_state", 1, nettype, name, iface.State, iface.StateReason)
if iface.SignalStrength != 0 {
c.setGauge64(ch, "network_signal_strength", float64(iface.SignalStrength), nettype, name)
}
}
}
}
}
func (c *powerwallCollector) newDesc(name string, desc string, labels []string) {
c.metrics[name] = prometheus.NewDesc(exporterName + "_" + name, desc, labels, nil)
}
func (c *powerwallCollector) Describe(ch chan<- *prometheus.Desc) {
for _, desc := range c.metrics {
ch <- desc
}
}
func (c *powerwallCollector) setGauge64(ch chan<- prometheus.Metric, name string, value float64, labels ...string) {
ch <- prometheus.MustNewConstMetric(c.metrics[name], prometheus.GaugeValue, value, labels...)
}
func (c *powerwallCollector) setGauge(ch chan<- prometheus.Metric, name string, value float32, labels ...string) {
c.setGauge64(ch, name, float64(value), labels...)
}
// grid faults