After sending the first message after a reset, the modem never responds +OK.

I've verified the issue with an Oscilloscope.

Settings:

  • EU868
  • Class A
  • OTAA
  • Adaptable datarate enabled
  • Dutycycle disabled

Reproducing this issue

  • Reset the modem
  • Use UTX
  • Await +OK

Expected result:

+EVENT=0,0\r\n\r\n+OK\r\n

Result:

+EVENT=0,0\r\n

@jpbaltazar jpbaltazar closed this as not planned Won't fix, can't repro, duplicate, stale Apr 26, 2024
@jpbaltazar jpbaltazar reopened this Apr 26, 2024
@jpbaltazar jpbaltazar changed the title First UTX after AT+JOIN seems to not return +OK First UTX after reset does not reply +OK Apr 26, 2024
@janakj
Copy link
Collaborator

janakj commented Apr 26, 2024

Thanks for reporting this. This might be a bug introduced in the recent commits. I will check this next week.

@janakj
Copy link
Collaborator

janakj commented May 18, 2024

Fixed in 1.4.1

@janakj janakj closed this as completed May 18, 2024