some commands for HPe CMU

  • HP Cluster Management Utility
  • Java GUI may work: java -jar cmugui.jar
  • pdsh is one of the commands from CMU

For RHEL6/CMU 7.X

  • sudo /opt/cmu/bin/cmu_power -p BOOT -n compnodeXX # boot a node
powering off compnode10 ...
spawning 1 task(s)       ................
waiting for 1 task(s)    ................ { last:compnode10 }
sleeping 10 seconds      ................
powering on compnode10 ...
spawning 1 task(s)       ................
waiting for 1 task(s)    ................ { last:compnode10 }
/opt/cmu/bin/cmu_power finished
  • sudo /opt/cmu/bin/cmu_monstat --nodes=compnode11 # show the list of sensors and values
  • sudo /opt/cmu/bin/cmu_power -p OFF -a # Shutdown all nodes
  • sudo /opt/cmu/bin/cmu_power -p OFF -n "compnode001 compnode002 ..." # Shutdown specific nodes
  • for i in {81..90} ; do sudo /opt/cmu/bin/cmu_power -p OFF -n "compnode$i" ; done # Shutdown through loop
  • for i in {81..90} ; do sudo /opt/cmu/bin/cmu_power -p STATUS -n "compnode$i" ; done # Check status through loop

For RHEL7/CMU 8.X

  • cmu_power -p REBOOT -n compcnodeXX # boot a node

Nitty-Gritty

when disk mout is not working

  • /etc/fstab is the configuration
  • sudo pdsh -w node# 'service netfs restart' # restarting nfs. Will not fix HW failure.
  • ssh into the node and run ip a. Check if ib card is detected.
  • ssh into the node and run hostname -l to see if ib card is detected.
  • sudo pdsh -w node# ibhosts to see if ib card is detected or working correctly.
  • If ib status is not correct, HW replacement might be necessary.