Skip to content

Latest commit

 

History

History

Yamaha HPH-200

Yamaha HPH-200

See usage instructions for more options and info.

Parametric EQs

You can use filters 1-5 or 1-10. Apply preamp of -6.4 dB or -6.4 dB, respectively.

# Type Fc (Hz) Q Gain (dB)
1 LowShelf 105 0.7 5.8
2 Peaking 41 0.94 3.8
3 Peaking 83 0.54 -6.4
4 Peaking 4730 1.88 6.7
5 Peaking 6680 4.6 -5.1
6 Peaking 243 1.68 -0.7
7 Peaking 518 1.05 1.1
8 Peaking 1328 2.04 -1.1
9 Peaking 8923 4.29 -2.3
10 HighShelf 10000 0.7 1.2

Fixed Band EQs

When using fixed band (also called graphic) equalizer, apply preamp of -7.9 dB (if available) and set gains manually with these parameters.

# Type Fc (Hz) Q Gain (dB)
1 Peaking 31 1.41 7.8
2 Peaking 62 1.41 0.8
3 Peaking 125 1.41 -3.4
4 Peaking 250 1.41 -2
5 Peaking 500 1.41 1.1
6 Peaking 1000 1.41 -0.5
7 Peaking 2000 1.41 -1
8 Peaking 4000 1.41 5.6
9 Peaking 8000 1.41 -2
10 Peaking 16000 1.41 2.3