You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
i have the following Vaillant Devices with esera ethernet koppler and running ebusd on raspPi3:
1 x VWF 1174/4 (Luftwärmepumpe)
1 x Multimatic 700 (Bedienteil)
1 x VR90 (Fernbedienung 2 Kreislauf)
1 x RecoVAIR 360/4 E + ebus Koppler (Wohnraumlüftung)
1 x VR71 (Mischersteuerung für 2 Kreisläufe)
1 x ALLStore (Pufferspeicher)
1 x AquaFLOW (Trinwassestation)
ebusctl -i only finds this:
`version: ebusd 3.4.v3.4
update check: OK
signal: acquired
symbol rate: 36
max symbol rate: 66
min arbitration micros: 54
max arbitration micros: 60
min symbol latency: 8
max symbol latency: 9
reconnects: 0
masters: 3
messages: 13
conditional: 0
poll: 0
update: 4
address 00: master #1
address 31: master #8, ebusd
address 33: master #13
address 36: slave #8, ebusd
address 38: slave #13, scanned "MF=Vaillant;ID=V32;SW=0117;HW=9802"
it also found one pmw device on address 0a, just give ebusd more time to finish the scan.
the V32 are bridge devices that are not really supported yet due to john30/ebusd#109 and referenced issues therein.
other than that, the net coupler is known to not work very good due to imposed latency as described in the wiki
Hello,
i have the following Vaillant Devices with esera ethernet koppler and running ebusd on raspPi3:
1 x VWF 1174/4 (Luftwärmepumpe)
1 x Multimatic 700 (Bedienteil)
1 x VR90 (Fernbedienung 2 Kreislauf)
1 x RecoVAIR 360/4 E + ebus Koppler (Wohnraumlüftung)
1 x VR71 (Mischersteuerung für 2 Kreisläufe)
1 x ALLStore (Pufferspeicher)
1 x AquaFLOW (Trinwassestation)
ebusctl -i only finds this:
`version: ebusd 3.4.v3.4
update check: OK
signal: acquired
symbol rate: 36
max symbol rate: 66
min arbitration micros: 54
max arbitration micros: 60
min symbol latency: 8
max symbol latency: 9
reconnects: 0
masters: 3
messages: 13
conditional: 0
poll: 0
update: 4
address 00: master #1
address 31: master #8, ebusd
address 33: master #13
address 36: slave #8, ebusd
address 38: slave #13, scanned "MF=Vaillant;ID=V32;SW=0117;HW=9802"
this is the config:
EBUSD_OPTS="--device=tcp:10.0.0.25:5000 --scanconfig -l /var/log/ebusd.log --latency=100000"
log file:
2019-11-12 18:11:31.001 [main notice] ebusd 3.4.v3.4 started with auto scan
2019-11-12 18:11:31.251 [bus notice] bus started with own address 31/36
2019-11-12 18:11:31.251 [bus notice] signal acquired
2019-11-12 18:12:57.395 [main notice] hex cmd: 3108070400
2019-11-12 18:15:17.080 [bus notice] device invalid
2019-11-12 18:15:22.106 [bus notice] re-opened tcp:10.0.0.25:5000
2019-11-12 18:15:40.803 [bus notice] device invalid
2019-11-12 18:15:45.829 [bus notice] re-opened tcp:10.0.0.25:5000
2019-11-12 18:15:46.032 [bus error] send to 08: ERR: read timeout, retry
2019-11-12 18:15:46.726 [bus error] send to 08: ERR: read timeout, retry
2019-11-12 18:15:47.203 [bus error] send to 08: ERR: read timeout, retry
2019-11-12 18:15:47.822 [bus error] send to 08: ERR: read timeout
2019-11-12 18:15:47.822 [main error] hex: ERR: read timeout
2019-11-12 18:15:47.877 [main notice] update check: OK
these are the settings from the esera ebus ethernet koppler:
pi@raspberrypi001:~ $ ebusctl hex 08070400
ERR: read timeout
pi@raspberrypi001:~ $ sudo ebusd --device=tcp:10.0.0.25:5000 --scanconfig=full -f
2019-11-12 19:14:16.407 [main notice] ebusd 3.4.v3.4 started with full scan
2019-11-12 19:14:16.730 [bus notice] bus started with own address 31/36
2019-11-12 19:14:16.730 [bus notice] signal acquired
2019-11-12 19:14:26.731 [main notice] starting initial full scan
2019-11-12 19:14:30.341 [bus notice] scan 0a: ;Vaillant;PMW01;0206;8302
2019-11-12 19:14:30.341 [update notice] store 0a ident: done
2019-11-12 19:14:30.341 [update notice] sent scan-read scan.0a QQ=31: Vaillant;PMW01;0206;8302
2019-11-12 19:14:30.341 [bus notice] scan 0a: ;Vaillant;PMW01;0206;8302
2019-11-12 19:14:32.746 [bus notice] scan 12: ;Vaillant;PMW01;0206;8302
2019-11-12 19:14:32.746 [update notice] store 12 ident: done
2019-11-12 19:14:32.746 [update notice] sent scan-read scan.12 QQ=31: Vaillant;PMW01;0206;8302
2019-11-12 19:14:32.746 [bus notice] scan 12: ;Vaillant;PMW01;0206;8302
2019-11-12 19:14:36.983 [main notice] read common config file vaillant/scan.csv
2019-11-12 19:14:37.039 [main notice] read common config file vaillant/general.csv
2019-11-12 19:14:37.094 [main notice] read common config file vaillant/broadcast.csv
2019-11-12 19:14:37.167 [main notice] read scan config file vaillant/0a.pmw.hwc.csv for ID "pmw01", SW0206, HW8302
2019-11-12 19:14:37.397 [main notice] found messages: 114 (15 conditional on 8 conditions, 0 poll, 8 update)
2019-11-12 19:14:40.931 [main error] unable to load scan config 12: no file from vaillant with prefix 12 found
2019-11-12 19:14:40.931 [main error] scan config 12: ERR: read timeout
2019-11-12 19:14:51.706 [bus notice] new master 33, master count 2
2019-11-12 19:14:51.707 [bus notice] scan 38: ;Vaillant;V32;0117;9802
2019-11-12 19:14:51.707 [update notice] store 38 ident: done
2019-11-12 19:14:51.707 [update notice] sent scan-read scan.38 QQ=31: Vaillant;V32;0117;9802
2019-11-12 19:14:51.707 [bus notice] scan 38: ;Vaillant;V32;0117;9802
2019-11-12 19:14:53.619 [main error] unable to load scan config 38: no file from vaillant with prefix 38 found
2019-11-12 19:14:53.619 [main error] scan config 38: ERR: read timeout
^X^C2019-11-12 19:16:04.136 [main notice] SIGINT received
Have really no idea. Please, need your help Thank you!
Chris
The text was updated successfully, but these errors were encountered: