@modenet
Copy link

modenet commented Nov 10, 2017

[main error] unable to load scan config 84: no file from /etc/ebusd/vaillant with prefix 84. matches ID "vr630", SW0306, HW6301
[main error] unable to load scan config 44: no file from /etc/ebusd/vaillant with prefix 44. found
[main error] unable to load scan config 08: no file from /etc/ebusd/vaillant with prefix 08. matches ID "bkm", SW0128, HW7601

can you help me tu find me the file requested by this legacy system?
thanks

@john30
Copy link
Owner

john30 commented Nov 17, 2017

for bkm i might have something, the others are duplicates of already existing devices as far as i remember

@modenet
Copy link
Author

modenet commented Nov 17, 2017

thanks you, please advise me when you public these new files (even if partial).

@modenet
Copy link
Author

modenet commented Dec 1, 2017

have you any news for bkm configuration files? thanks

@john30
Copy link
Owner

john30 commented Dec 3, 2017

the converted bkm file simply consists of a single line including the hcmode.inc, so the use is very limited. Here is the content of the "08.bkm.csv" file:
# type (r[1-9];w;u),circuit,name,comment,QQ,ZZ,PBSB,ID,field,part (m/s),datatypes/templates,divider/values,unit,comment #,BKM,VR 30,BKM 176,,,,,,,,,, !include,hcmode.inc,,,,,,,,,,,,

@modenet
Copy link
Author

modenet commented Dec 4, 2017

ok, now from readall I obtain only:
bkm DateTime =
bkm SetMode = ERR: no data stored
bkm Status =
bkm Status01 =
bkm Status02 =
bkm Status16 =

is correct ?
thank you a lot!

@modenet
Copy link
Author

modenet commented Dec 4, 2017

can you help me even for this two new requests?
[main error] unable to load scan config 15: no file from /etc/ebusd/vaillant with prefix 15. matches ID "b7v00", SW0422, HW5503
[main error] unable to load scan config 76: no file from /etc/ebusd/vaillant with prefix 76. found

@john30
Copy link
Owner

john30 commented Dec 6, 2017

hm, can you simply check with "ebusctl find -a -d" after it ran for one day or so?
for the unknown messages, please start with posting your scan result ("ebusctl scan && sleep 30 && ebusctl can result").

@modenet
Copy link
Author

modenet commented Dec 6, 2017

ebusctl find -a -d returned me nothing about BKM

root@vaillant:~# ebusctl find -a -d|grep BKM
scan.08 = Vaillant;BKM ;0128;7601
scan.18 = Vaillant;BKM ;0128;7601

@modenet
Copy link
Author

modenet commented Dec 6, 2017

unable to load scan config 15: no file from /etc/ebusd/vaillant with prefix 15. matches ID "b7v00", SW
unable to load scan config e8: no file from /etc/ebusd/vaillant with prefix e8. found
unable to load scan config 76: no file from /etc/ebusd/vaillant with prefix 76

scan result:
08;Vaillant;HMU01;0304;8802;21;17;33;0010011972;1610;005254;N9
15;Vaillant;B7V00;0422;5503
26;Vaillant;VR_71;0104;0503;21;17;09;0020184847;0082;005484;N5
76;Vaillant;VWZIO;0111;0103;21;17;01;0020117049;0082;005045;N2
e8;Vaillant;FMU00;0202;6502;21;17;33;0010011972;1610;005254;N9

info:
version: ebusd 3.0.v3.0-12-g77d2a80
signal: acquired
symbol rate: 122
max symbol rate: 164
reconnects: 0
masters: 4
messages: 71
conditional: 0
poll: 0
update: 8
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=HMU01;SW=0304;HW=8802", loaded "vaillant/08.hmu.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=B7V00;SW=0422;HW=5503"
address 26: slave, scanned "MF=Vaillant;ID=VR_71;SW=0104;HW=0503", loaded "vaillant/26.vr_71.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address 71: master #9
address 76: slave #9, scanned "MF=Vaillant;ID=VWZIO;SW=0111;HW=0103"
address e8: slave, scanned "MF=Vaillant;ID=FMU00;SW=0202;HW=6502"

@john30
Copy link
Owner

john30 commented Dec 17, 2017

[main error] unable to load scan config 15: no file from /etc/ebusd/vaillant with prefix 15. matches ID "b7v00", SW0422, HW5503
I'm afraid I habe no information at all for this controller/user interface. The "7" might be a hint that it could be similar to e.g. 15.e7f or so, but that's really hard to tell.

The 76 I've seen before, but there are no known definitions for that one as well.

@modenet
Copy link
Author

modenet commented Dec 20, 2017

other configuration lacking:

[main error] unable to load scan config f8: no file from /etc/ebusd/vaillant with prefix f8. found
unable to load scan config 84: no file from /etc/ebusd/vaillant with prefix 84. matches ID "vr630", SW0500, HW6301
unable to load scan config 18: no file from /etc/ebusd/vaillant with prefix 18. found
unable to load scan config 38: no file from /etc/ebusd/vaillant with prefix 38. found
unable to load scan config 78: no file from /etc/ebusd/vaillant with prefix 78. found
unable to load scan config 24: no file from /etc/ebusd/vaillant with prefix 24. found

localhost: scan result
08;Vaillant;BAI00;0609;5502;21;16;44;0010010784;0001;005093;N4
15;Vaillant;UI ;0508;6201;21;16;21;0020080467;0907;005481;N6
18;Vaillant;V32;0117;9802
23;Vaillant;VR630;0500;6301;21;16;21;0020092435;0907;005187;N1
24;Vaillant;V32;0117;9802
25;Vaillant;VR630;0500;6301;21;16;21;0020092435;0907;005187;N1
26;Vaillant;VR630;0500;6301;21;16;21;0020092435;0907;005187;N1
38;Vaillant;V32;0117;9802
50;Vaillant;VR630;0500;6301;21;16;21;0020092435;0907;005187;N1
51;Vaillant;VR630;0500;6301;21;16;21;0020092435;0907;005187;N1
52;Vaillant;MC2 ;0500;6301;21;16;38;306782<<<<;0907;005019;N1
53;Vaillant;MC2 ;0500;6301;21;16;38;306782<<<<;0907;005019;N1
75;Vaillant;RC C ;0508;6201;21;16;16;0020040079;0907;005312;N1
78;Vaillant;V32;0117;9802
f5;Vaillant;RC C ;0508;6201;21;15;50;0020040079;0907;007735;N1
f8;Vaillant;V32;0117;9802

@john30
Copy link
Owner

john30 commented Dec 21, 2017

afaik 84 is exactly the same as one of the other VR630 devices, so no new information to gather.
18, 38, and 78 are all bus couplers, right? what devices are attached there?

@modenet
Copy link
Author

modenet commented Dec 27, 2017

hi, vr32 is necessary to connect many boilers together.
84's messages can be ignored?
thanks

@john30
Copy link
Owner

john30 commented Dec 27, 2017

yes afaik.
again the same question: what devices are attached behind the vr32?

@modenet
Copy link
Author

modenet commented Dec 27, 2017

Same boiler connected togheter
08;Vaillant;BAI00;0609;5502;21;16;44;0010010784;0001;005093;N4
Vr32 have a switch with a progressive Number which is necessary to have multiple boiler works togheter.
(I don't know the exact model, I'll tell you next data)

@john30
Copy link
Owner

john30 commented Dec 28, 2017

the thing is, such a special configuration would have to be supported by ebusd in the first place. so this does not work until issue 109 is solved. After that ebusd would have to be extended even further so that it can actively handle bridges and special messages to pass through those and reach the heater behind it. this is somewhat complicated and not easily solved.

@modenet
Copy link
Author

modenet commented Dec 28, 2017

Thanks