On M600 drives (PTC sensor), if you short the thermistor wires the temperature reading will be -100°C and a real overtemp will never be detected.
On BBSHD, same thing happens with an open thermistor.
The code should have a lower limit to detect a sensor fault and stop the motor
The text was updated successfully, but these errors were encountered:
No branches or pull requests
On M600 drives (PTC sensor), if you short the thermistor wires the temperature reading will be -100°C and a real overtemp will never be detected.
On BBSHD, same thing happens with an open thermistor.
The code should have a lower limit to detect a sensor fault and stop the motor