This document should give an overview regarding the used APIs and the possible data that can be queried.

Data that can be accessed in the local network from a Senec V3 device

Basis for this documentation is the firmware version 0826.

The following information are provided by the device. Since no open acceccible API documentation exists, the following description is an assumption.

  • The following information can be accessed sending a post request with a JSON-Payload to https://[IP of the senec device]/lala.cgi
  • As response a JSON String is returned
  • Please note: Depending on the firmware version the Request has to be via http or https. (https starting with the firmware version 825)

Logfile

The logfile of the device can be accessed via URL and shows a raw text file. The URL has the following format: https://[IP of the device]//log/[year]/[month]/[day].log (and YES there are two / behind the ip-address since v0826)

Example: https://192.168.1.115//log/2023/10/05.log

VarMon & Chart

It is possible to get a list of all variables and their values of the device, even if Senec claimed that this data is only accessible by themselves (since 0826) - the access is still possible for every owner without any kind of hacks.

version url
before v0825 https://[IP of the device]/vars.html
v0825 https://[IP of the device]/Vars.html
v0826 https://[IP of the device]//vars.html

Example: https://192.168.1.115//vars.html

lala.cgi Request Example

To gather data we have to send a POST-Request to the Senec device ("lala.cgi"), that has a JSON-String as payload. Here an request example with all objects that can be requested. Many of the objects have sub-objects:

POST https://[my-ip]/lala.cgi HTTP/1.1
content-type: application/json

{
"DEBUG":{},
"BAT1":{},
"BAT1OBJ1":{},
"BMS":{},
"BMS_PARA":{},
"CASC":{},
"DISPLAY":{},
"ENERGY":{},
"FACTORY":{},
"FEATURES":{},
"FILE":{},
"GRIDCONFIG":{},
"LOG":{},
"PM1":{},
"PM1OBJ1":{},
"PM1OBJ2":{},
"PV1":{},
"PWR_UNIT":{},
"RTC":{},
"SELFTEST_RESULTS":{},
"SOCKETS":{},
"STATISTIC":{},
"STECA":{},
"SYS_UPDATE":{},
"TEMPMEASURE":{},
"TEST":{},
"UPDATE":{},
"WALLBOX":{},
"WIZARD":{},
"CURRENT_IMBALANCE_CONTROL":{},
"BMZ_CURRENT_LIMITS":{},
"CELL_DEVIATION_ROC":{},
"SENEC_IO_INPUT":{},
"SENEC_IO_OUTPUT":{},
"IPU":{},
"FAN_TEST":{},
"FAN_SPEED":{}
}

Response Example

The response returns a JSON-String for the requested object. In this example the "ENERGY" was used. The values are in hex format and have to be decoded in dec, int or float.

{
    "ENERGY": {
        "STAT_STATE": "u8_0D",
        "GUI_BAT_DATA_POWER": "fl_BF08E2C1",
        "GUI_INVERTER_POWER": "fl_4599AD17",
        "GUI_HOUSE_POW": "fl_442047C0",
        "GUI_GRID_POW": "fl_C585A866",
        "GUI_BAT_DATA_FUEL_CHARGE": "fl_428C0000",
        "GUI_CHARGING_INFO": "u8_00",
        "GUI_BOOSTING_INFO": "u8_00"
    }
}

Category DEBUG

Information from the DEBUG-Object:

Object Example value Description
CHARGE_TARGET
DC_TARGET
FEED_TARGET
PU_AVAIL
SECTIONS Assumption: Could be a (not complete) list of objects that contain data.

Category "ENERGY"

Information from the ENERGY-Object:

Object Example value Description
CAPTESTMODULE [0.0, 0.0, 0.0, 0.0 ]
GUI_BAT_DATA_COLLECTED 1
GUI_BAT_DATA_CURRENT -6.849999904632568
GUI_BAT_DATA_FUEL_CHARGE 82.82827758789062 Battery fuel charge in percent, as shown in the gui, wenn accessing the device via browser.
GUI_BAT_DATA_MAX_CELL_VOLTAGE 3929
GUI_BAT_DATA_MIN_CELL_VOLTAGE 3923
GUI_BAT_DATA_POWER -376.57867431640625 Positive: Watt with which the battery is charged; Negative: Watts with which the battery is discharged
GUI_BAT_DATA_VOLTAGE 54.974998474121094
GUI_BOOSTING_INFO 1
GUI_CAP_TEST_STATE 0
GUI_CHARGING_INFO 0
GUI_GRID_POW -6.079999923706055 A positive value corresponds to a mains reference, a negative value to a net feed-in. This is the same data shown in the gui, when accessing the device via browser.
GUI_HOUSE_POW 370.4986877441406
GUI_INIT_CHARGE_START 0
GUI_INIT_CHARGE_STOP 0
GUI_INVERTER_POWER -0.0 Sum of currently generated PV electricity in watts
GUI_TEST_CHARGE_STAT 0
GUI_TEST_DISCHARGE_STAT 0
INIT_CHARGE_ACK 0
INIT_CHARGE_DIFF_VOLTAGE 0.0
INIT_CHARGE_MAX_CURRENT 0.0
INIT_CHARGE_MAX_VOLTAGE 0.0
INIT_CHARGE_MIN_VOLTAGE 0.0
INIT_CHARGE_RERUN 0
INIT_CHARGE_RUNNING 0
INIT_CHARGE_STATE 0
INIT_CHARGE_TIMER 0
INIT_DISCHARGE_MAX_CURRENT 0.0
LI_STORAGE_MODE_RUNNING 0
LI_STORAGE_MODE_START 0
LI_STORAGE_MODE_STOP 0
OFFPEAK_DURATION 0
OFFPEAK_POWER 0.0
OFFPEAK_RUNNING 0
OFFPEAK_TARGET 100
SAFE_CHARGE_FORCE 0
SAFE_CHARGE_PROHIBIT 0
SAFE_CHARGE_RUNNING 0
STAT_HOURS_OF_OPERATION 9993 Number of hours since the system was activated
STAT_LIMITED_NET_SKEW 0
STAT_STATE 16 Status of the system, see detailed definition in section "Translation of System State Name Enums to Text"
VPP_ACTIVATE_EXPORT_LIMIT 0
VPP_ACTIVATE_TARGET_POWER 0
VPP_DAILY_PARAMETER_RESET 1
VPP_ENDTIME_HOUR 0
VPP_ENDTIME_MINUTE 0
VPP_EXPORT_LIMIT 0
VPP_IGNORE_COUNTRY_TYPE 0
VPP_IS_ACTIVE 0
VPP_LAST_CHANGE_UTC 0
VPP_STARTTIME_HOUR 0
VPP_STARTTIME_MINUTE 0
VPP_TARGET_POWER 0.0
ZERO_EXPORT 0

Translation of ENERGY STAT_STATE Name ENUMS to Text

Representations of STAT_STATE

ENUM Description
0 INITIALZUSTAND
1 KEINE KOMMUNIKATION LADEGERAET
2 FEHLER LEISTUNGSMESSGERAET
3 RUNDSTEUEREMPFAENGER
4 ERSTLADUNG
5 WARTUNGSLADUNG
6 WARTUNGSLADUNG FERTIG
7 WARTUNG NOTWENDIG
8 MAN. SICHERHEITSLADUNG
9 SICHERHEITSLADUNG FERTIG
10 VOLLLADUNG
11 AUSGLEICHSLADUNG: LADEN
12 SULFATLADUNG: LADEN
13 AKKU VOLL
14 LADEN
15 AKKU LEER
16 ENTLADEN
17 PV + ENTLADEN
18 NETZ + ENTLADEN
19 PASSIV
20 AUSGESCHALTET
21 EIGENVERBRAUCH
22 NEUSTART
23 MAN. AUSGLEICHSLADUNG: LADEN
24 MAN. SULFATLADUNG: LADEN
25 SICHERHEITSLADUNG
26 AKKU-SCHUTZBETRIEB
27 EG FEHLER
28 EG LADEN
29 EG ENTLADEN
30 EG PASSIV
31 EG LADEN VERBOTEN
32 EG ENTLADEN VERBOTEN
33 NOTLADUNG
34 SOFTWAREAKTUALISIERUNG
35 FEHLER: NA-SCHUTZ
36 FEHLER: NA-SCHUTZ NETZ
37 FEHLER: NA-SCHUTZ HARDWARE
38 KEINE SERVERVERBINDUNG
39 BMS FEHLER
40 WARTUNG: FILTER
41 ABSCHALTUNG LITHIUM
42 WARTE AUF ÜBERSCHUSS
43 KAPAZITÄTSTEST: LADEN
44 KAPAZITÄTSTEST: ENTLADEN
45 MAN. SULFATLADUNG: WARTEN
46 MAN. SULFATLADUNG: FERTIG
47 MAN. SULFATLADUNG: FEHLER
48 AUSGLEICHSLADUNG: WARTEN
49 NOTLADUNG: FEHLER
50 MAN: AUSGLEICHSLADUNG: WARTEN
51 MAN: AUSGLEICHSLADUNG: FEHLER
52 MAN: AUSGLEICHSLADUNG: FERTIG
53 AUTO: SULFATLADUNG: WARTEN
54 LADESCHLUSSPHASE
55 BATTERIETRENNSCHALTER AUS
56 PEAK-SHAVING: WARTEN
57 FEHLER LADEGERAET
58 NPU-FEHLER
59 BMS OFFLINE
60 WARTUNGSLADUNG FEHLER
61 MAN. SICHERHEITSLADUNG FEHLER
62 SICHERHEITSLADUNG FEHLER
63 KEINE MASTERVERBINDUNG
64 LITHIUM SICHERHEITSMODUS AKTIV
65 LITHIUM SICHERHEITSMODUS BEENDET
66 FEHLER BATTERIESPANNUNG
67 BMS DC AUSGESCHALTET
68 NETZINITIALISIERUNG
69 NETZSTABILISIERUNG
70 FERNABSCHALTUNG
71 OFFPEAK-LADEN
72 FEHLER HALBBRÜCKE
73 BMS: FEHLER BETRIEBSTEMPERATUR
74 FACTORY SETTINGS NICHT GEFUNDEN
75 NETZERSATZBETRIEB
76 NETZERSATZBETRIEB AKKU LEER
77 NETZERSATZBETRIEB FEHLER
78 INITIALISIERUNG
79 INSTALLATIONSMODUS
80 NETZAUSFALL
81 BMS UPDATE ERFORDERLICH
82 BMS KONFIGURATION ERFORDERLICH
83 ISOLATIONSTEST
84 SELBSTTEST
85 EXTERNE STEUERUNG
86 TEMPERATUR SENSOR FEHLER
87 NETZBETREIBER: LADEN GESPERRT
88 NETZBETREIBER: ENTLADEN GESPERRT
89 RESERVEKAPAZITÄT
90 SELBSTTEST FEHLER
91 ISOLATIONSFEHLER
92 PV-MODUS
93 FERNABSCHALTUNG NETZBETREIBER
94 FEHLER DRM0
95 BATTERIEDIAGNOSE
96 BALANCING
97 SICHERHEITSENTLADUNG
98 BMS FEHLER - MODULUNGLEICHGEWICHT
99 AUFWACHLADUNG

Category FEATURES

Features of Senec device, represented in the FEATURES-Object:

Object Example value Description
CAR 1 installation of wallbox possible?
CLOUDREADY 1
ECOGRIDREADY 1
HEAT 1 Connection to heat module like asko heat possible?
ISLAND 1 module backup power installed?
ISLAND_PRO 1 module backup power pro installed?
PEAKSHAVING 1 peak shaving is possible
SGREADY 1 Smart grid ready
SHKW 0
SOCKETS 0

Category FILE

Returns an empty object

Category LOG

Information represented bei the LOG-Object:

Object Example value Description
LOG_IN_BUTT 0
LOG_IN_NOK_COUNT 0 Number of wrong login attempts
LOG_OUT_BUTT 0
PASSWORD
USERNAME
USER_LEVEL 0

Category DISPLAYSYS_UPDATE

Unknown, what the DISPLYSYS-Object represents:

"DISPLAYSYS_UPDATE":{ "OBJECT_NOT_FOUND":"" },

Category WIZARD

Information represented by the WIZARD-Object:

Object Example value Description
APPLICATION_HASH 05feefa49abec4a123f6883386a48497562caa8
APPLICATION_VERSION 1824
BATT_IPU_MISMATCH 0
BOOT 1
CHARGE_PRIO 0
CONFIG_CHECKSUM 40231
CONFIG_LOADED 1
CONFIG_MODIFIED_BY_USER 0
CONFIG_WRITE 0
DEVICE_BATTERY_TYPE 4
DEVICE_INVERTER_TYPE 66 Model of the inverter.
DEVICE_INV_ENABLED [1, 0, 0, 0, 0, 0]
DEVICE_INV_PHASES_ARR [4, 4, 4, 4, 4, 4]
DEVICE_INV_SLAVE_ADRESS [1, 4, 5, 6, 7, 8]
DEVICE_PM_GRID_ENABLED 1
DEVICE_PM_HOUSE_ENABLED 0
DEVICE_PM_TYPE 1
DEVICE_WB_TYPE 0
FEATURECODE_ENTERED 0
FIRMWARE_VERSION 954 Version of the firmware
GENERATION_METER_SN 0
GRID_CONNECTION_TYPE 2
GUI_LANG 0
HEATPUMP_METER_SN 0
HEAT_CONN_TYPE 2
INSULATION_RESISTANCE 1000
INTERFACE_VERSION 1964
LOGGER_SEVERITY 8
MAC_ADDRESS_BYTES [10, 21, 246, 11, 222, 116]
MASTER_SLAVE_ADDRESSES [0, 0, 0, 0, 0, 0]
MASTER_SLAVE_MODE 0
POWER_METER_SERIAL 0
PS_ENABLE 0
PS_HOUR 0
PS_MINUTE 0
PS_RESERVOIR 0
PV_CONFIG [1, 1]
PWRCFG_PEAK_PV_POWER 9500.0 Max. PV power of system in watts
SENEC_METER_SN 0
SETUP_ABS_POWER 0
SETUP_HV_PHASE 0
SETUP_NUMBER_WALLBOXES 0
SETUP_PM_GRID_ADR 1
SETUP_PM_HOUSE_ADR 2
SETUP_POWER_RULE 100
SETUP_PV_INV_IP0 0
SETUP_PV_INV_IP1 0
SETUP_PV_INV_IP2 0
SETUP_PV_INV_IP3 0
SETUP_PV_INV_IP4 0
SETUP_PV_INV_IP5 0
SETUP_RCR_STEPS [0, 30, 60, 100]
SETUP_USED_PHASE 1
SETUP_USE_ABS_POWER 0
SETUP_USE_DRM0 0
SETUP_USE_RCR 0
SETUP_WALLBOX_SERIAL0
SETUP_WALLBOX_SERIAL1
SETUP_WALLBOX_SERIAL2
SETUP_WALLBOX_SERIAL3
SG_READY_CURR_MODE 1
SG_READY_ENABLED 0
SG_READY_ENABLE_OVERWRITE 0
SG_READY_EN_MODE1 0
SG_READY_OVERWRITE_RELAY [0, 0]
SG_READY_POWER_COMM 65535
SG_READY_POWER_PROP 65535
SG_READY_TIME 720
TEST_EG_METER 0
TEST_GENERATION_METER 0
TEST_HEATPUMP_METER 0
TEST_SENEC_METER 0
ZEROMODULE 0

Category BMS

Information represented by the BMS-Object:

Object Example value Description
ALARM_STATUS [0, 0, 0, 0]
BATTERY_STATUS [0, 0, 0, 0]
BL [12480, 12480, 12480, 0]
BMS_READY_FLAG 1
BMS_STATUS 1
BMS_STATUS_TIMESTAMP 1689953960
CELL_BALANCE_STATUS [0, 0, 0, 0]
CELL_TEMPERATURES_MODULE_A [30, 30, 31, 30, 31, 31] Temperature of the battery cells of module A. For each cell a sensor is set up.
CELL_TEMPERATURES_MODULE_B [30, 30, 31, 31, 31, 31] Temperature of the battery cells of module B. For each cell a sensor is set up.
CELL_TEMPERATURES_MODULE_C [31, 31, 32, 32, 32, 32] Temperature of the battery cells of module C. For each cell a sensor is set up.
CELL_TEMPERATURES_MODULE_D [0, 0, 0, 0, 0, 0] Temperature of the battery cells of module D. For each cell a sensor is set up.
CELL_VOLTAGES_MODULE_A [3926, 3926, 3926, 3926, 3926, 3926, 3925, 3923, 3926, 3926, 3926, 3927, 3926, 3927]
CELL_VOLTAGES_MODULE_B [3928, 3926, 3926, 3926, 3926, 3927, 3926, 3923, 3927, 3926, 3927, 3927, 3927, 3928]
CELL_VOLTAGES_MODULE_C [3929, 3929, 3928, 3928, 3928, 3929, 3928, 3926, 3928, 3928, 3928, 3928, 3928, 3929]
CELL_VOLTAGES_MODULE_D [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]
CHARGED_ENERGY [60293836, 307496975, 267112777, 0]
CHARGE_CURRENT_LIMIT [12.0, 12.0, 12.0, 0.0]
COMMERRCOUNT 0
CURRENT [-2.2799999713897705, -2.2899999618530273, -2.2799999713897705, 0.0]
CYCLES [27, 29, 14, 0] Assumption: Number of charging cycles per module
DERATING 0
DISCHARGED_ENERGY [290682267, 291850974, 30869157, 0]
DISCHARGE_CURRENT_LIMIT [-24.0, -24.0, -24.0, 0.0]
ERROR 0
FAULTLINECOUNT 2
FW [39637, 39637, 39637, 0]
HW_EXTENSION [2, 2, 2, 0]
HW_MAINBOARD [3002, 3002, 3002,0]
MANUFACTURER 2
MAX_CELL_VOLTAGE [3927, 3928, 3929, 0]
MAX_TEMP 320
MIN_CELL_VOLTAGE [3923, 3923, 3926, 0]
MIN_TEMP 300
MODULES_CONFIGURED 3 Number of configured modules
MODULE_COUNT 3 Number of battery modules
NOM_CHARGEPOWER_MODULE 625.0 Nominal charging power for each module
NOM_DISCHARGEPOWER_MODULE 1250.0 Nominal discharge power for each module
NR_INSTALLED 3 Number of installed batteries
PROTOCOL 0
RECOVERLOCKED 0
SERIAL ["", "", "", ""]
SN [44043416, 44043417, 44043418, 0]
SOC [83, 83, 83, 0]
SOH [99, 99, 99, 0]
STATUS [1, 1, 1, 0]
SYSTEM_SOC 830
TEMP_MAX [31, 31, 32, 0]
TEMP_MIN [30, 30, 31, 0]
TF_ERROR 0
VOLTAGE [54.96200180053711, 54.970001220703125, 54.99399948120117, 0.0]
WIZARD_ABORT 1
WIZARD_CONFIRM 0
WIZARD_DCCONNECT 0
WIZARD_START 0
WIZARD_STATE 0

Translation of the BMS_STATUS ENUMS

ENUM Description
1 Warning: cell overvoltage
2 Alarm: cell overvoltage
3 Error: cell overvoltage
4 Warning: cell undervoltage
5 Alarm: cell undervoltage
6 Error: cell undervoltage
7 Alarm: module overvoltage
8 Alarm: module undervoltage
9 Error: cell overtemperature
10 Error: cell undertemperature
11 Warning: cell overtemperature charging
12 Alarm: cell overtemperature charging
13 Warning: cell undertemperature charging
14 Alarm: cell undertemperature charging
15 Warning: cell overtemperature discharging
16 Alarm: cell overtemperature discharging
17 Warning: cell undertemperature discharging
18 Alarm: cell undertemperature discharging
19 Warning: charging current
20 Alarm: charging current
21 Warning: discharging current
22 Alarm: discharging current
23 Warning: cells imbalanced
24 Alarm: cells imbalanced
25 Warning: board temperature too high
26 Alarm: board temperature too high
27 Warning: checking temperature difference
28 Alarm: checking temperature difference
29 Warning: checking current difference
30 Alarm: checking current difference
31 Selftest SCP failed

Category BAT1

Information represented by the BAT1-Object:

Object Example value Description
CEI_LIMIT 0
DRM0_ASSERT 0
ISLAND_ENABLE 1 Assumption: Is the emergency power available?
NSP2_FW 6
NSP_FW 10
RESET 0
SELFTEST_ACT [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
SELFTEST_LIMIT [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
SELFTEST_OFF [0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
SELFTEST_OVERALL_STATE 5
SELFTEST_STATE [0, 0, 0, 0, 0, 0, 0, 0]
SELFTEST_STEP ["", "", "", "", "", "", "", ""]
SELFTEST_TIME [0, 0, 0, 0, 0, 0, 0, 0]
SERIAL "783234JD028547840519"
SPARE_CAPACITY 15 Set reserve capacity for emergency power supply
TRIG_ITALY_SELF 0
TYPE 4 Battery type

Translation of the Selftest result ENUMs

ENUM Description
0 Undefined
1 Running
2 Success
3 Failed
4 Never Runned
5 Not Started

Translation of the Selftest step ENUMs

ENUM Description
0 Upper Voltage Limit L1
1 Lower Voltage Limit L1
2 Upper Freq Limit L1
3 Lower Freq Limit L1
4 Upper 10 Min Avg Limit L1
5 Ext Upper Freq Limit L1
6 Ext Lower Freq Limit L1
7 Lower Voltage Limit 2 L1

Category BAT1OBJ1

Information represented by the BAT1OBJ1-Object:

Object Example value Description
COMM 0
I_DC -6.744999885559082
P 0
Q 0
S 0
SW_VERSION 51380244
SW_VERSION2 67305482
SW_VERSION3 84148230
TEMP1 42
TEMP2 49
TEMP3 0
TEMP4 0
TEMP5 0
U_DC 54.85300064086914

Category BAT1OBJ2

Information represented by the BAT1OBJ2-Object: "BAT1OBJ2":{ "OBJECT_NOT_FOUND":"" },

Category BAT1OBJ3

Information represented by the BAT1OBJ3-Object: "BAT1OBJ3":{ "OBJECT_NOT_FOUND":"" },

Category BAT1OBJ4

Information represented by the BAT1OBJ4-Object: "BAT1OBJ4":{ "OBJECT_NOT_FOUND":"" },

Category PWR_UNIT

Information represented by the PWR_UNIT-Object:

Object Example value Description
ADRESS [0, 0, 0, 0, 0, 0]
CONNPWR [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CONNPWR_1 [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CONNPWR_2 [ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CONNPWR_3 [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CURRENTTEMP_MAX [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CURRENTTEMP_MAX_HW [ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CURRENTTEMP_MIN [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
CURRENTTEMP_MIN_HW [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
ENFLURI [0, 0, 0, 0, 0, 0]
FW_VER [0, 0, 0, 0, 0, 0]
HW_REV [0, 0, 0, 0, 0, 0]
POWER [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
POWER_L1 [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
POWER_L2 [ 0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
POWER_L3 [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
PU_MISSING 0
REQ_POWER [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
SERIAL ["", "", "", "", "", ""]
STATUS [0, 1, 2, 3, 4, 5]
TEMPMAX [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
TEMPMIN [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
TEMPTARGET [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
TEMP_COUNT [0, 0, 0, 0, 0, 0]
TEMP_LIMIT_LOWER 0.0
TEMP_LIMIT_UPPER 100.0
TYPE [0, 0, 0, 0, 0, 0]
WATERVOL [0, 0, 0, 0, 0, 0]

Translation of the PWR_UNIT TYPE ENUM

ENUM Description
0 N/A
1 Solarinvert SHKW
2 SENEC.Heat

Category PV1

Information represented by the PV1-Object:

Object Example value Description
ERROR_STATE_INT [0, 0]
INTERNAL_INV_ERROR_TEXT ["", ""]
INTERNAL_INV_ERR_STATE_VALID [1, 0]
INTERNAL_INV_STATE [2, 5]
INTERNAL_MD_AVAIL [1, 0]
INTERNAL_MD_MANUFACTURER ["Senec", ""] Manufacturer
INTERNAL_MD_MODEL ["V3 LV", ""] Currently used model
INTERNAL_MD_SERIAL ["7a7553H304H544250424", ""]
INTERNAL_MD_VERSION ["HMI: 3.16.20 PU: 4.3.10 BDC: 5.4.6", ""]
INTERNAL_PV_AVAIL 1
INV_MODEL ["", "", "st_END_OF_ARRAY"]
INV_SERIAL ["", "","st_END_OF_ARRAY"]
INV_VERSIONS ["HMI: 3.16.20 PU: 4.3.10", "","st_END_OF_ARRAY"]
MPP_AVAIL 2 Number of available MPPs
MPP_CUR [0.0, 0.0, 0.0]
MPP_POWER [0.0, 0.0, 0.0] Power for each MPP in watts. For each MPP a sensor is set up.
MPP_VOL [60.202003479003906, 66.80500030517578, 0.0] Voltage of each MPP
POWER_RATIO 100.0
POWER_RATIO_L1 100.0
POWER_RATIO_L2 100.0
POWER_RATIO_L3 100.0
PV_MISSING 0
P_TOTAL 0.0
STATE_INT [272, 0]
TYPE 66

Category BMS_PARA

Information represented by the BMS_PARA-Object:

Object Example value Description
FORCE_BMS_ERROR 0
FORCE_OP_MODE 0
FULL_CELL_VOLTAGE_MV 4069
MAX_BATTERY_TEMP_LIMIT_DEG 45
MAX_MODULE_CHARGE_CURRENT_LIMIT_A 12
MAX_MODULE_DISCHARGE_CURRENT_LIMIT_A 65512
OPERATIONAL_MODE 2
USE_ROA_PARAMETER 0

Category CASC

Information represented by the CASC-Object:

Object Example value Description
BATPOWERSUM -376.0310363769531
POWER [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
PVGEN [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]
PVMASTER 0.0
SOC [100.0, 100.0, 100.0, 100.0, 100.0, 100.0]
STATE [0, 0, 0, 0, 0, 0]
TARGET [0.0, 0.0, 0.0, 0.0, 0.0, 0.0]

Category DISPLAY

Returns an empty object

Category FACTORY

Information represented by the FACTORY-Object:

Object Example value Description
BAT_TYPE 4 Battery type
CELL_TYPE 5 Cell type
COUNTRY 0
DESIGN_CAPACITY 7500.0 Capacity of available batteries
DEVICE_ID "2525866113258324220991834"
EPA_GRID_FILTER 0
FAC_SANITY 1
MAX_CHARGE_POWER_DC 1875.0 Sum of power the available batteries can be charged
MAX_DISCHARGE_POWER_DC 3750.0 Sum of power the available batteries can be discharged
PM_TYPE 1
SYS_TYPE 17

Translation of the FACTORY BAT_TYPE ENUM

ENUM Description
0 Studer Xtender
1 SenecBatt
2 Senec.Inverter V2
3 SENEC.Inverter V2.1
4 SENEC.Inverter V3 LV

Category GRIDCONFIG

Information represented by the GRIDCONFIG-Object:

Object Example value Description
PWRCFG_COS_POINT1 1
PWRCFG_COS_POINT3 0.95
PWRCFG_COS_POINT_2A 1
PWRCFG_COS_POINT_2B 50
PWRCFG_USE_MAX_PWR_SKEW 1
VDECOSPHITIME 10
VDEFIXEDFAC 0.9
VDEOVERFREQDROOP 5
VDEOVERFREQLIMIT 50.2
VDEPT1RESPONSETIME 0
VDERECOVERTIME 10
VDETARGETTY 1
VDEUNDERFREQDROOP 2
VDE_FREQDROPPROT 47.5
VDE_FREQDROPPROTDELAY 0.1
VDE_FREQRISEPROT 51.5
VDE_FREQRISEPROTDELAY 0.1
VDE_UNDERFREQLIMIT 49.8
VDE_VOLTDROPPROT 45
VDE_VOLTDROPPROTAVG 80
VDE_VOLTDROPPROTAVGDELAY 3
VDE_VOLTDROPPROTDELAY 0.3
VDE_VOLTRISEPROT 125
VDE_VOLTRISEPROTAVG 110
VDE_VOLTRISEPROTAVGDELAY 0.1
VDE_VOLTRISEPROTDELAY 0.1

Category PM1

Information represented by the PM1-Object:

Object Example value Description
MB_SL2MA_CONN 0
MB_SLAVES_COUNT 0
PWR_METERS_MISSING 0
TYPE 1

Category PM1OBJ1

Information represented by the PM1OBJ1-Object - ENFLURI 1:

Object Example value Description
ADR 1
ENABLED 1
FREQ 50.05999755859375 Frequency of the power grid
I_AC [1.159999966621399, 0.35999998450279236, 1.0] Current in amps for each phase. For each phase a single sensor is set up.
P_AC [-234.3199920654297, 49.84000015258789, 174.45999145507812] Current power (w) of each phase. For each phase a single sensor is set up.
P_TOTAL -10.029999732971191
U_AC [229.40000915527344, 230.3000030517578, 228.40000915527344] Current voltage per phase. For each phase a single sensor is set up.

Category PM1OBJ2

Information represented by the PM1OBJ2-Object - ENFLURI 2:

Object Example value Description
ADR 2
ENABLED 0
FREQ 0.0
I_AC [0.0, 0.0, 0.0]
P_AC [0.0, 0.0, 0.0]
P_TOTAL 0.0
U_AC [0.0, 0.0, 0.0]

Category RTC

Information represented by the RTC-Object:

Object Example value Description
TIMESTAMP_MS 1314036527
UTC_OFFSET 120
WEB_TIME 1691275183

Category SELFTEST_RESULTS

Information represented by the SELFTEST_RESULTS-Object:

Object Example value Description
DC_COIL Test passed
INIT_BATTERY_MODULES Test passed
INSULATION Test passed
INTERRUPT No Interrupt
IPU Test not initialized

Category SOCKETS

Information represented by the SOCKETS-Object:

Object Example value Description
ALREADY_SWITCHED [0, 0]
ENABLE [0, 0]
FORCE_ON [0, 0]
LOWER_LIMIT [0, 0]
NUMBER_OF_SOCKETS 2
POWER_ON [0, 0]
POWER_ON_TIME [0, 0]
PRIORITY [0, 0]
RESET_SWITCHED 0
SWITCH_ON_HOUR [0, 0]
SWITCH_ON_MINUTE [0, 0]
TIME_LIMIT [0, 0]
TIME_REM [0, 0]
UPPER_LIMIT [0, 0]
USE_TIME [0, 0]

Category "STATISTIC"

Returns an empty object.

Category STECA

Information represented by the STECA-Object:

Object Example value Description
AU2020_VERSION_MISMATCH 0
BAT 1
BDC_STATE [262144, 0, 1073741824]
ERROR 0
ERRORTEXT ""
ISLAND 1
NUM_PV_CONFIG_POSSIBLE 10
PV 1
PVSS 4
PV_CONFIG_POSSIBLE [1, 1, 1, 2, 16, 1, 1, 16, 16, 16]
PV_INPUTS 2 Number of MPPs provided
RELAYS 15
STARTUP 272 See tranlation of ENUMS below - 272=Run Grid
STARTUP_ADD 4294967295

Translation of the ENUMS for the STARTUP Variable

ENUM Description
0 StabilizeMcuSupply
16 StartHighSidePwm
32 StartAuxSupply
48 StartMonitoring
64 ThermalManagement
80 StartProtection
88 CheckIslanding
96 DegaussRCD
112 GetAcOffset
128 SwitchOnRelaisSupply
136 CheckStrings
140 EstablishLink
141 BlackStart
144 TestAcRelais
160 TestDcRelais
176 SwitchOnDcRelais
184 CheckDcShortcircuitAndPolarity
192 GetDcOffset
208 TestRcd
224 IsolationCheck
228 SwitchOnENS
232 ReestablishLink
236 RecheckIslanding
237 EstablishIslandingLink
238 ConfirmIslanding
240 WaitEnsClearance
256 EstablishAcVoltage
264 RunIslanding
272 RunGrid
280 CheckShortFault
288 SafeState
304 Sleep
312 SleepAfterIslanding
320 ShutdownForSleep
336 SystemReset
352 WaitForReset

Category SYS_UPDATE

Information represented by the SYS_UPDATE-Object:

Object Example value Description
FSM_STATE 1
MISC [0, 0, 0, 0, 0, 0]
NPU_IMAGE_VERSION 2011
NPU_VER 9
UPDATE_AVAILABLE 0
USER_REBOOT_DEVICE 0
USER_REQ_UPDATE 0

Category TEMPMEASURE

Information represented by the TEMPMEASURE-Object:

Object Example value Description
BATTERY_TEMP 32.0 Temperature of the batteries in °C
CASE_TEMP 39.308067321777344 Temperature of the case in °C
MCU_TEMP 49.744564056396484 Temperature of the MCU in °C
TEMP_DATA_COLLECTED 1

Category TEST

Returns an empty object.

Category UPDATE

Returns an empty object.

Category WALLBOX

Information represented by the WALLBOX-Object:

Object Example value Description
ADDITIONAL_ERROR [0, 0, 0, 0]
ALLOW_INTERCHARGE 0
APPARENT_CHARGING_POWER [0.0, 0.0, 0.0, 0.0]
BUS_ADR [1, 2, 3, 4]
CS_ENABLED [0, 0, 0, 0]
DETECTION_MODE 0
EV_CONNECTED [0, 0, 0, 0]
HW_TYPE [0, 0, 0, 0]
L1_CHARGING_CURRENT [0.0, 0.0, 0.0, 0.0]
L1_USED [0, 0, 0, 0]
L2_CHARGING_CURRENT [0.0, 0.0, 0.0, 0.0]
L2_USED [0, 0, 0, 0]
L3_CHARGING_CURRENT [0.0, 0.0, 0.0, 0.0]
L3_USED [0, 0, 0, 0]
LOAD_IMBALANCE_DETECTED [0, 0, 0, 0]
LOAD_IMBALANCE_ENABLED [0, 0, 0, 0]
MAJOR_REV [0, 0, 0, 0]
MAX_CHARGING_CURRENT_DEFAULT [0.0, 0.0, 0.0, 0.0]
MAX_CHARGING_CURRENT_IC [0.0, 0.0, 0.0, 0.0]
MAX_CHARGING_CURRENT_ICMAX [0.0, 0.0, 0.0, 0.0]
MAX_CHARGING_CURRENT_RATED [0.0, 0.0, 0.0, 0.0]
MAX_PHASE_CURRENT_BY_GRID 0.0
MAX_TOTAL_CURRENT_BY_GRID 0.0
METER_ENABLED [0, 0, 0, 0]
METHOD_EN1 [0, 0, 0, 0]
MINOR_REV [0, 0, 0, 0]
MIN_CHARGING_CURRENT [ 0.0, 0.0, 0.0, 0.0]
PHASES_USED [0, 0, 0, 0]
PROHIBIT_USAGE [0, 0, 0, 0]
SAP_NUMBER ["", "", "", ""]
SERIAL_NUMBER ["", "", "", ""]
SERIAL_NUMBER_INTERNAL ["", "", "", ""]
SET_ICMAX [0.0, 0.0, 0.0, 0.0]
SET_IDEFAULT [0.0, 0.0, 0.0, 0.0]
SMART_CHARGE_ACTIVE [0, 0, 0, 0]
SOCKET_ENABLED [0, 0, 0, 0]
STATE [0, 0, 0, 0]
UID [0, 0, 0, 0]
UTMP [0, 0, 0, 0]

Translation of Wallbox STATE ENUM

ENUM Description
0x00 invalid state
0xA1 not connected
0xA2 not connected
0xB1 connected
0xB2 ready
0xC2 charging
0xC3 charging with reduced power (high temperature)
0xC4 charging with reduced power (unbalanced load limitation)
0xE0 deactivated (enabling contact)
0xF1 contact error
0xF2 internal error
0xF3 fault current detected
0xF4 EV charger communication error
0xF5 locking error
0xF6 cable error
0xF7 vehicle overtemperature
0xF8 vehicle communication error
0xF9 power supply error
0xFA temperature too high
0xFB contact error

Category CURRENT_IMBALANCE_CONTROL

Information represented by the Current_IMBALANCE_CONTROL-Object:

Object Example value Description
THRESHOLD_mA 8000 Threadshold

Category BMZ_CURRENT_LIMITS

Information represented by the BMZ_CURRENT_LIMITS-Object:

Object Example value Description
MIN_CURRENT_LIMIT_A 65512
MAX_CURRENT_LIMIT_A 12

Category CELL_DEVIATION_ROC

Information represented by the CELL_DEVIATION_ROC-Object:

Object Example value Description
SKIP_WAITING 0

Category SENEC_IO_INPUT

Information represented by the SENEC_IO_INPUT-Object:

Object Example value Description
STATUS_DC_SWITCH_IPU_V5 1
FAULTLINE_DELAYED 0
FAULTLINE 0
STATUS_AC_SWITCH_IPU_V3 0
ISOGUARD_STATUS 1
DRY_CONTACT_IN_IPU_V5 1
DC_HK_STATUS_IPU_V5 0
POWER_STATUS 1
HID3_IPU_V5 0
HID2_IPU_V5 1
HID1 1
HID0 0
RCD_RMS_IPU_V3 1
RCD_ERROR_IPU_V3 1
RCD_DC_IPU_V3 0
AC_ERROR_IPU_V3 1

Category SENEC_IO_OUTPUT

Information represented by the SENEC_IO_OUTPUT-Object:

Object Example value Description
BAT_MODULE_ENABLE_SAMSUNG_IPU_V5 0 1 =Samsung Modules are used
BAT_MODULE_ENABLE_BMZ 1 1 = BMZ Modules are used
KILLSWITCH 0
Relay_4 0
Relay_3 0
Relay_2 0
Relay_1 0
ISOGUARD_ENABLE 0
DC_SWITCH 1
AC_SWITCH_IPU_V3 0
DRY_CONTACT_OUT_IPU_V5 1
RCD_RESET_IPU_V3 0
RCD_TEST_IPU_V3 1

Category IPU

Information represented by the IPU-Object:

Object Example value Description
VERSION 2

Category FAN_TEST

Information represented by the FAN_TEST-Object:

Object Example value Description
INV_LV 0
INV_HV 0

Category FAN_SPEED

Information represented by the FAN_SPEED-Object:

Object Example value Description
INV_LV 0
INV_HV 0

Category V_STECA

Information represented by the V_STECA-Object:

Object Example value Description
percent#v 0.0
percent#vf 0.0
percent#f 0

Web API

The following Information can be accessed via the Web-API (mein-senec.de).

Peak Shaving

Read/Get Information

When logged in, call the following URL via GET: https://mein-senec.de/endkunde/api/peakshaving/getSettings?anlageNummer=0

Response

{
    "einspeisebegrenzungKwpInPercent": 100, #export limit in kwh in percent
    "peakShavingMode": "DEACTIVATED", #Current mode DEACTIVATED, MANUAL, AUTO
    "peakShavingCapacityLimitInPercent": 0, #Battery capacity limit in percent
    "peakShavingLocalEndTime": [
        0,
        0
    ],
    "bearbeitungsdatum": 1665062808000,
    "bearbeiter": {
        "id": 111111,
        "geloescht": false,
        "userRole": "STUB",
        "aktiv": false
    },
    "valid": true,
    "peakShavingEndDate": 1696723200000 #END time of peak shaving
}

URL to set Settings

To set the changed configuration call ("GET") the following URL and set the respective query string parameter: https://mein-senec.de/endkunde/api/peakshaving/saveSettings?anlageNummer=0&mode=AUTO&capacityLimit=0&endzeit=1697414400000

Definition of variables

Mode ("peakShavingMode" in response to read the current data, "mode" in request to save changes)
  • Deactivated = no peak shaving, only dynamic export limit. Defined as "DEACTIVATED" in get and save Settings
  • Manual = manual peak shaving parameter assignment. Defined as "MANUAL" in get and save Settings
  • Automatic = forecast-based peak shaving parameter assignment (BETA). Defined as "AUTO" in get and save Settings
Capacity limit ("peakShavingCapacityLimitInPercent" in response to read the current data,"capacityLimit" in request to save changes)
  • Temporarily limits the capacity of the battery storage, so that the remaining capacity can be used for potential losses due to the export limit.
End ("peakShavingEndDate" in response to read the current data, "endzeit" in request to save changes)
  • Time of the day on which the capacity limitation should switch off again.