Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathmain.py
197 lines (155 loc) · 6.97 KB
/
main.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
import pandas as pd
from getpass import getpass
import requests
import json
import pdu_controller
"""
Processes data from Extron Global Viewer Enterprise Server
Finds and reports offline devices at run time.
Matches switched PDU's in rooms with offline devices.
Can automatically reboot switched PDU outlets if desired.
"""
with open("config.json", "r") as config_file:
config = json.load(config_file)
pdu_controller.IGNORE_OUTLETS = config["Ignore_Outlets"]
URL = config["GVE_URL"]
TARGET_DEVICE_TYPES = config["Device_Types"]
API = {
"auth": f"{URL}:443/GVE/api/auth",
"controllers": f"{URL}:443/GVE/api/controllers",
"rooms": f"{URL}:443/GVE/api/rooms",
"devices": f"{URL}:443/GVE/api/devices",
}
# Magic strings for device status
ACTIVE = "Active"
CONNECTED = "Connected"
DISCONNECTED = "Disconnected"
class GVE:
def __init__(self) -> None:
self.user = config["Username"]
self.password = getpass(f"Enter Password for {self.user}:")
self.session = self.authenticate(self.user, self.password)
self.rooms = self.get_data(self.session, API["rooms"])
self.devices = self.get_data(self.session, API["devices"])
self.controllers = self.get_data(self.session, API["controllers"])
def authenticate(self, user, pw) -> requests.Session:
print("Generating Session...")
session = requests.Session()
data = {"UserName": user, "Password": pw}
auth_url = API["auth"]
response = session.post(auth_url, data=data)
if response.status_code != 200:
print("Authentication Failed")
exit(1)
return session
def get_data(self, session, command):
response = session.get(command)
data = response.json()
return data
def load_json(file_path: str) -> dict:
"""Loads a json file from disk"""
try:
with open(file_path, "r") as json_file:
data = json.load(json_file)
return data
except:
print(f"Error loading json file {file_path}")
def validate_device_types(devices_df: pd.DataFrame) -> None:
"""Ensures that everything in TARGET_DEVICE_TYPES is present in the data retrived from GVE"""
for device_type in TARGET_DEVICE_TYPES:
# controllers are evaulated separately
if device_type.upper() == "CONTROLLER":
continue
unique_device_types = devices_df["DeviceType"].unique()
if device_type not in unique_device_types:
print(f"Device type {device_type} in Config.json is not valid.")
print(f"Valid device types are: {unique_device_types}")
exit(1)
def get_user_reboot_preference() -> str:
user_input = input("Auto Power Toggle? (Y/N): ")
if user_input.upper() not in ["Y", "N"]:
print("Invalid input. Please enter Y or N.")
get_user_reboot_preference()
return user_input
def main() -> None:
user_auto_power_preference = get_user_reboot_preference()
user_auto_power_preference = user_auto_power_preference.upper()
try:
pdu_data = load_json("PDU.json")
except FileNotFoundError as e:
print("Cannot find PDU.json")
print("Auto reboot functionality will not be available")
user_auto_power_preference = "N"
gve_connection = GVE()
# Load root data from GVE into flattened dataframes
devices_df = pd.json_normalize(gve_connection.devices["Devices"])
rooms_df = pd.json_normalize(gve_connection.rooms["Rooms"])
controllers_df = pd.json_normalize(gve_connection.controllers["Controllers"])
validate_device_types(devices_df)
# Recreate the devices dataframe with only:
# - devices of the target type
# - devices that are active
# - devices that are reporting disconnected
devices_df = devices_df.query(
"`DeviceType` in @TARGET_DEVICE_TYPES and `Status` == @ACTIVE and `LiveStatus.Connection` == @DISCONNECTED"
)
# Recreate the controllers dataframe with only offline controllers
controllers_df = controllers_df.query("`IsOnline` == False")
# Extract room id and controller IP from the controllers dataframe,
# and add them to the devices dataframe, as merging would create issues
for _, row in controllers_df.iterrows():
controller_row = {
"RoomId": row["RoomId"],
"DeviceType": f"Controller at {row['NetworkSettings.IPAddress']}",
}
devices_df = pd.concat(
[devices_df, pd.DataFrame([controller_row])], ignore_index=True
)
# Merge devices and rooms dataframes based on shared key: RoomId
merged_df = pd.merge(devices_df, rooms_df, on="RoomId")
# Recreate the merged dataframe without ignored rooms (as specified in the config file)
merged_df = merged_df.query("`RoomName` not in @config['Ignore_Rooms']")
# Group device issues per room using RoomName as the key. Make it look pretty.
offline_report_df = merged_df.groupby("RoomName", as_index=False).agg(
{"DeviceType": lambda x: ", ".join(x), "RoomId": "first"}
)
if user_auto_power_preference == "N":
print(offline_report_df)
# optional: prints just the room names for copy/paste into a ticket
print(offline_report_df["RoomName"].values)
else:
# IP address of devices connected to processors are not provided by GVE,
# so we have to load an outside data source to get them.
pdu_df = pd.DataFrame(pdu_data)
pdu_password = getpass("Enter PDU Password: ")
# Add the PDU data into a merged dataframe
offline_report_with_pdu_df = pd.merge(
offline_report_df,
pdu_df[["RoomId", "PDU_IP"]],
on="RoomId",
how="left",
)
print(offline_report_with_pdu_df)
print(offline_report_df["RoomName"].values)
with open("offline_report.csv", "w") as csv_file:
offline_report_with_pdu_df.to_csv(csv_file, index=False)
# Iterate over the dataframe and send reboot commands to switched PDU's
for _, row in offline_report_with_pdu_df.iterrows():
room_name = row["RoomName"]
pdu_ip_list = row["PDU_IP"]
# Rooms without PDU's are NaN and skipped
if not isinstance(pdu_ip_list, list):
continue
else: # room has PDU(s)
print("---------------------------------------------------")
print(f"{room_name} : Found PDU(s) at {pdu_ip_list}")
try:
for pdu_ip in pdu_ip_list:
pdu_controller.main(str(pdu_ip), str(room_name), pdu_password)
except Exception as e:
print(
f"{room_name} : Error sending reboot command to {pdu_ip} : {e}"
)
continue
if __name__ == "__main__":