PV showing values when it shouldn't #128

Closed
ghost opened this issue Jul 9, 2022 · 1 comment
Closed

PV showing values when it shouldn't #128

ghost opened this issue Jul 9, 2022 · 1 comment

Comments

@ghost
Copy link

ghost commented Jul 9, 2022

I have a GW5000S-BP. There are no PV panels on this inverter. There is another PV inverter which the CT clamps of the Goodwe read for PV generation for battery charging etc..

the integration sensors for PV show values when I think they should not be

Its currently night here so no sun light at all, but the sensors for PV show values (highlighted in red box)

Screen Shot 2022-07-09 at 9 46 35 pm

@mletenay
Copy link
Owner

mletenay commented Aug 9, 2022

Well, there is absolutely no calculation done at the integration and/or the underlying communication library code related to PV values. They are directly reported by the inverter and presented as is.
They only solution could be to completely remove/hide the PV related values from BPS models, but I'm not really sure I like that idea, so I suggest to accept reality and leave it be ;-)
If you insist on hiding it, please report it to goodwe library repo and I'll see what can be done there...

@mletenay mletenay closed this as completed Aug 9, 2022