Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathinstDMM_Prototype.m
156 lines (145 loc) · 5.41 KB
/
instDMM_Prototype.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
%% instDMM_Prototype.m MN 2020-07-01
% Template for DMM interface
%
% Requirements:
% - VISA interface functions in path
% - Equipment is connected on specified VISA address
%
% Usage: measurement = instDMM_Prototype(visaAddr, option[, value])
% Returns:
% measurement: Selected measurement, if requested
%
% Parameters:
% visaAddr: Valid VISA address with a DMM connected
% 'option': One of available options below
% 'value': Value for options that require it
%
% Options:
% 'reset': Resets/initializes power meter to defaults
% 'state', %i: Turns output on or off
% 'on': Same as 'state', 1
% 'off': Same as 'state', 0
% 'current', %f: Sets output current to this if possible (amps)
% 'voltage', %f: Sets output voltage to this if possible (volts)
% 'ilimit', %f: Set output current limit (amps)
% 'vlimit', %f: Set output voltage limit (volts)
% 't', %f: Averages measurements on-device for this long
% 'wires', 2 | 4: Set voltage measurement mode to 2 or 4 wire
% 'outI': Return output current setpoint
% 'outV': Return output voltage setpoint
% 'outlim': Return output limits [Ilim; Vlim]
% 'measI': Returns current measurement (amps)
% 'measV': Returns voltage measurement (volts)
% 'measIV': Returns current and voltage measurement [I; V]
% 'measR': Returns resistance measurement (ohms)
% 'avgt': Return averaging time
%
% TODO:
% - Implement all functions!
% - Add more options?
% - Confirm units
function measurement = instDMM_Prototype(visaAddr, option, value)
measurement = [];
%% Helper functions
dmmWrite = @(x) visaWrite(visaAddr, x);
dmmQuery = @(x) str2double(visaRead(visaAddr, x));
%% Execute selected command
switch lower(option)
case 'reset'
% Set standard settings
dmmWrite('*RST'); pause(0.5);
dmmWrite('*CAL?'); % If available
dmmWrite('DEFAULT_VALUES');
case {'state', 'on', 'off'}
% Find the state if not specified
if ~exist('value', 'var'); value = find(strcmpi(option, {'off', 'on'}),1)-1; end
% Set state
switch value > 0
case 1
dmmWrite('COMMAND_ENABLE_OUT');
case 0
dmmWrite('COMMAND_DISABLE_OUT');
end
case 'current'
% Set output current
if ~exist('value', 'var'); error('Value not provided for output current!'); end
% Switch range if needed
% Set output: CHECK UNITS
dmmWrite(sprintf('COMMAND_CURRENT_OUT %f', double(value))); % Input in A
case 'voltage'
% Set output voltage
if ~exist('value', 'var'); error('Value not provided for output voltage!'); end
% Switch range if needed
% Set output: CHECK UNITS
dmmWrite(sprintf('COMMAND_VOLTAGE_OUT %f', double(value))); % Input in A
case 'ilimit'
% Set current output limit
if ~exist('value', 'var'); error('Value not provided for current limit!'); end
% Switch range if needed
% Set limit: CHECK UNITS
dmmWrite(sprintf('COMMAND_I_LIMIT %f', double(value)));
case 'vlimit'
% Set voltage output limit
if ~exist('value', 'var'); error('Value not provided for voltage limit!'); end
% Switch range if needed
% Set limit: CHECK UNITS
dmmWrite(sprintf('COMMAND_V_LIMIT %f', double(value)));
case 't'
% Set averaging time
% Calculate units or filters if needed
dmmWrite(sprintf('COMMAND_AVG_T %f', double(value)));
case 'wires'
% Set 2 or 4 wire measurement mode
if ~exist('value', 'var'); error('Value not provided for wire measurement mode!'); end
% Select measurement mode
switch round(value)
case 2
dmmWrite('COMMAND_2WIRE');
case 4
dmmWrite('COMMAND_4WIRE');
otherwise
error('Invalid wire number specified: %i', value)
end
case 'outi'
% Retreive output current setpoint
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_I_SET');
case 'outv'
% Retreive output voltage setpoint
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_V_SET');
case 'outlim'
% Retreive output [I; V] limits
% Read value: CHECK UNITS
measurement = [dmmQuery('COMMAND_READ_I_LIM'); ...
dmmQuery('COMMAND_READ_V_LIM')];
case 'measi'
% Measure output current
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_I_OUT');
case 'measv'
% Measure output voltage
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_V_OUT');
case 'measiv'
% Measure output I and V
% Read value: CHECK UNITS
measurement = [dmmQuery('COMMAND_READ_I_OUT'); ...
dmmQuery('COMMAND_READ_V_OUT')];
case 'measr'
% Measure resistance
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_R');
case 'avgt'
% Retreive averaging time
% Read value: CHECK UNITS
measurement = dmmQuery('COMMAND_READ_T_AVG');
% Calculate units if needed
otherwise
if ~isempty(option)
error('Unexpected option "%s"', num2str(option));
end
end
%% Clean up
dmmWrite('LOCAL'); % Switch back to local mode if possible
end