Notifications
You must be signed in to change notification settings - Fork 0
/
mks_901p.py
455 lines (440 loc) · 21.2 KB
/
mks_901p.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
"""
usage: mks_901p.py [-h] [--find_baud] [--baud BAUD] [-unit] serial_port
positional arguments:
serial_port the Windows COM port or path to a linux serial port
optional arguments:
-h, --help show this help message and exit
--find_baud tries to access the sensor over all supported baud rates,
prints which is successful
--baud BAUD baud rate to connect with, defaults to 9600 (901p factory
default)
-unit print pressure unit with each reading
"""
# xxx = Transducer communication address (001 to 253. Broadcast addresses: 254, 255)
baud_supported = [4800, 9600, 19200, 38400, 57600, 115200, 230400]
commands = {
'Communication information': {
'get_baud_rate': {
'Command': '@{}BR?;FF',
'Response': '@xxxACK9600;FF',
'Explanation': 'Communication baud rate (4800, 9600, 19200, 38400, 57600, 115200,230400)'
},
'get_address': {
'Command': '@{}AD?;FF',
'Response': '@xxxACK253;FF',
'Explanation': 'Transducer communication address (001 to 253)'
},
'get_comms_delay': {
'Command': '@{}RSD?;FF',
'Response': '@xxxACKON;FF',
'Explanation': 'Communication delay between receive and transmit sequence.'
}
},
'Pressure reading': {
'pirani': {
'Command': '@{}PR1?;FF',
'Response': '@xxxACK1.23E-3;FF',
'Explanation': 'MicroPirani sensor pressure as 3 digit floating point value.'},
'piezo': {
'Command': '@{}PR2?;FF',
'Response': '@xxxACK-7.60E+2;FF',
'Explanation': 'Piezo differential sensor pressure as 3 digit floating point value.'},
'combined_3_digit': {
'Command': '@{}PR3?;FF',
'Response': '@xxxACK1.23E-3;FF',
'Explanation': 'Combined reading as 3 digit floating point value.'},
'combined_4_digit': {
'Command': '@{}PR4?;FF',
'Response': '@xxxACK1.234E-3;FF',
'Explanation': 'Combined reading as 4 digit floating point value.'}
},
'Setpoint information': {
'get_setpoint_1_status': {
'Command': '@{}SS1?;FF',
'Response': '@xxxACKSET;FF',
'Explanation': 'Set point relay 1-3 status (SET=Relay energized / CLEAR=Relay deenergized'},
'get_setpoint_2_status': {
'Command': '@{}SS2?;FF',
'Response': '@xxxACKSET;FF',
'Explanation': 'Set point relay 1-3 status (SET=Relay energized / CLEAR=Relay deenergized'},
'get_setpoint_3_status': {
'Command': '@{}SS3?;FF',
'Response': '@xxxACKSET;FF',
'Explanation': 'Set point relay 1-3 status (SET=Relay energized / CLEAR=Relay deenergized'},
'get_setpoint_1': {
'Command': '@{}SP1?;FF',
'Response': '@xxxACK1.00E-2;FF',
'Explanation': 'Set point 1-3 switch value.'},
'get_setpoint_2': {
'Command': '@{}SP2?;FF',
'Response': '@xxxACK1.00E-2;FF',
'Explanation': 'Set point 1-3 switch value.'},
'get_setpoint_3': {
'Command': '@{}SP3?;FF',
'Response': '@xxxACK1.00E-2;FF',
'Explanation': 'Set point 1-3 switch value.'},
'get_hysteresis_1': {
'Command': '@{}SH1?;FF',
'Response': '@xxxACK1.10E-2;FF',
'Explanation': 'Set point 1-3 hystereses switch value.'},
'get_hysteresis_2': {
'Command': '@{}SH2?;FF',
'Response': '@xxxACK1.10E-2;FF',
'Explanation': 'Set point 1-3 hystereses switch value.'},
'get_hysteresis_3': {
'Command': '@{}SH3?;FF',
'Response': '@xxxACK1.10E-2;FF',
'Explanation': 'Set point 1-3 hystereses switch value.'},
'get_setpoint_1_enabled': {
'Command': '@{}EN1?;FF',
'Response': '@xxxACKDIFF;FF',
'Explanation': 'Set point 1-3 enable status ( OFF, DIFF=Piezo differential or ABS=Absolute Piezo)'},
'get_setpoint_2_enabled': {
'Command': '@{}EN2?;FF',
'Response': '@xxxACKDIFF;FF',
'Explanation': 'Set point 1-3 enable status ( OFF, DIFF=Piezo differential or ABS=Absolute Piezo)'},
'get_setpoint_3_enabled': {
'Command': '@{}EN3?;FF',
'Response': '@xxxACKDIFF;FF',
'Explanation': 'Set point 1-3 enable status ( OFF, DIFF=Piezo differential or ABS=Absolute Piezo)'},
'get_setpoint1_relay_direction': {
'Command': '@{}SD1?;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW) If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'get_setpoint2_relay_direction': {
'Command': '@{}SD2?;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW) If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'get_setpoint3_relay_direction': {
'Command': '@{}SD3?;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW) If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'get_setpoint_safety_delay': {
'Command': '@{}SPD?;FF',
'Response': '@xxxACKON;FF',
'Explanation': 'Setpoint safety delay'}
},
'Transducer information': {
'get_model': {
'Command': '@{}MD?;FF',
'Response': '@xxxACK901P;FF',
'Explanation': 'Model number (901P)'},
'get_devicetype': {
'Command': '@{}DT?;FF',
'Response': '@xxxACKLoadlock;FF',
'Explanation': 'Device type name (MicroPirani)'},
'get_mfg': {
'Command': '@{}MF?;FF',
'Response': '@xxxACKMKS;FF',
'Explanation': 'Manufacturer name (MKS)'},
'get_hw_version': {
'Command': '@{}HV?;FF',
'Response': '@xxxACKA;FF',
'Explanation': 'Hardware version'},
'get_fw_version': {
'Command': '@{}FV?;FF',
'Response': '@xxxACK1.00;FF',
'Explanation': 'Firmware version'},
'get_serial_num': {
'Command': '@{}SN?;FF',
'Response': '@xxxACK08350123456;FF',
'Explanation': 'Serial number'},
'get_switch': {
'Command': '@{}SW?;FF',
'Response': '@xxxACKON;FF',
'Explanation': 'Switch enable'},
'get_time_on': {
'Command': '@{}TIM?;FF',
'Response': '@xxxACK12345;FF',
'Explanation': 'Time on (hours of operation )'},
'get_pirani_temp': {
'Command': '@{}TEM?;FF',
'Response': '@xxxACK2.50E+1;FF',
'Explanation': 'MicroPirani sensor temperature'},
'get_usertext': {
'Command': '@{}UT?;FF',
'Response': '@xxxACKVACUUM1;FF',
'Explanation': 'User programmed text string'},
'get_status': {
'Command': '@{}T?;FF',
'Response': '@xxxACKO;FF',
'Explanation': 'Transducer status check'}
},
'Calibration and adjustment information': {
'get_pressure_unit': {
'Command': '@{}U?;FF',
'Response': '@xxxACKTORR;FF',
'Explanation': 'Pressure unit setup (Torr, mbar or Pascal)'},
'get_calibration_gas': {
'Command': '@{}GT?;FF',
'Response': '@xxxACKNITROGEN;FF',
'Explanation': 'MicroPirani sensor calibration gas (Nitrogen, Air, Argon, Helium, Hydrogen, H2O, Neon, CO2, Xenon)'},
'get_factory_diff_zero_point': {
'Command': '@{}VAC?;FF',
'Response': '@xxxACK5.12E-5;FF',
'Explanation': 'Provides delta pressure value between current vacuum zero adjustment and factory calibration.'},
'get_factory_diff_atmosphere': {
'Command': '@{}ATM?;FF',
'Response': '@xxxACK1.22E+1;FF',
'Explanation': 'Provides delta pressure value between current atmospheric adjustment and factory calibration.'},
'get_analog_out_1': {
'Command': '@{}AO1?;FF',
'Response': '@xxxACK10;FF',
'Explanation': 'Analog voltage output 1: Pressure assignment and calibration. (first digit is pressure assignment, second and third digit is calibration)'},
'get_analog_out_2': {
'Command': '@{}AO2?;FF',
'Response': '@xxxACK10;FF',
'Explanation': 'Analog voltage output 2: Pressure assignment and calibration. (first digit is pressure assignment, second and third digit is calibration)'}
},
'Setpoint setup and configuration': {
'set_setpoint_1':{
'Command': '@{}SP1!2.00E+1;FF',
'Response': '@xxxACK2.00E+1;FF',
'Explanation': 'Set point 1-3 switch value.'},
'set_setpoint_2':{
'Command': '@{}SP2!2.00E+1;FF',
'Response': '@xxxACK2.00E+1;FF',
'Explanation': 'Set point 1-3 switch value.'},
'set_setpoint_3':{
'Command': '@{}SP3!2.00E+1;FF',
'Response': '@xxxACK2.00E+1;FF',
'Explanation': 'Set point 1-3 switch value.'},
'set_hysteresis_1':{
'Command': '@{}SH1!5.00E+1;FF',
'Response': '@xxxACK5.00E+1;FF',
'Explanation': 'Set point 1-3 hysteresis switch value.'},
'set_hysteresis_2':{
'Command': '@{}SH2!5.00E+1;FF',
'Response': '@xxxACK5.00E+1;FF',
'Explanation': 'Set point 1-3 hysteresis switch value.'},
'set_hysteresis_3':{
'Command': '@{}SH3!5.00E+1;FF',
'Response': '@xxxACK5.00E+1;FF',
'Explanation': 'Set point 1-3 hysteresis switch value.'},
'enable_setpoint_1':{
'Command': '@{}EN1!ON;FF',
'Response': '@xxxACKON;FF',
'Explanantion': 'Set point 1-3 enable status (ON or OFF)'},
'enable_setpoint_2':{
'Command': '@{}EN2!ON;FF',
'Response': '@xxxACKON;FF',
'Explanantion': 'Set point 1-3 enable status (ON or OFF)'},
'enable_setpoint_3':{
'Command': '@{}EN3!ON;FF',
'Response': '@xxxACKON;FF',
'Explanantion': 'Set point 1-3 enable status (ON or OFF)'},
'set_setpoint1_relay_direction':{
'Command': '@{}SD1!BELOW;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW). If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'set_setpoint2_relay_direction':{
'Command': '@{}SD2!BELOW;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW). If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'set_setpoint3_relay_direction':{
'Command': '@{}SD3!BELOW;FF',
'Response': '@xxxACKBELOW;FF',
'Explanation': 'Set point relay direction (ABOVE or BELOW). If set to above relay will be energized above setpoint value. If set to below relay will be energized below setpoint value.'},
'set_setpoint_safety_delay':{
'Command': '@{}SPD!ON;FF',
'Response': '@xxxACKON;FF',
'Explanation': 'Setpoint safety delay (prevent pulse trig of setpoint)'}
},
'Communication setup': {
'set_baud_rate': {
'Command': '@{}BR!19200;FF',
'Response': '@xxxACK19200;FF',
'Explanation': 'Set communication Baud rate (4800, 9600, 19200, 38400, 57600, 115200, 230400)'},
'set_address': {
'Command': '@{}AD!123;FF',
'Response': '@xxxACK123;FF',
'Explanation': 'Set Transducer communication address (001 to 253)'},
'set_comms_delay': {
'Command': '@{}RSD!OFF;FF',
'Response': '@xxxACKOFF;FF',
'Explanation': 'Turn on or off communication delay between receive and transmit sequence.'}
},
'Calibration and adjustment': {
'set_pressure_unit': {
'Command': '@{}U!MBAR;FF',
'Response': '@xxxACKMBAR;FF',
'Explanation': 'Set pressure unit setup (Torr, mbar, Pascal)'},
'set_calibration_gas': {
'Command': '@{}GT!ARGON;FF',
'Response': '@xxxACKARGON;FF',
'Explanation': 'Set MicroPirani sensor calibration gas. (Nitrogen, Air, Argon, Helium, Hydrogen, H2O, Neon, CO2, Xenon)'},
'perform_pirani_zero_adjustment': {
'Command': '@{}VAC!;FF',
'Response': '@xxxACK;FF',
'Explanation': 'Executes MicroPirani zero adjustment'},
'perform_pirani_atmosphere_adjustment': {
'Command': '@{}ATM!7.60E+2;FF',
'Response': '@xxxACK;FF',
'Explanation': 'Executes MicroPirani full scale atmospheric adjustment.'},
'perform_piezo_absolute_adjustment': {
'Command': '@{}ATD!7.60E+2;FF',
'Response': '@xxxACK;FF',
'Explanation': 'Executes Piezo absolute reading at zero differential pressure.'},
'perform_piezo_differential_adjustment': {
'Command': '@{}ATZ;FF',
'Response': '@xxxACK;FF',
'Explanation': 'Executes Piezo differential zero adjustment'},
'set_analog_out_1': {
'Command': '@{}AO1!10;FF',
'Response': '@xxxACK10;FF',
'Explanation': 'Set analog voltage output 1 calibration.'},
'set_analog_out_2': {
'Command': '@{}AO1!10;FF',
'Response': '@xxxACK10;FF',
'Explanation': 'Set analog voltage output 2 calibration.'}
},
'Information setup': {
'set_user_tag':{
'Command': '@{}UT!LOADLOCK;FF',
'Response': '@xxxACKLOADLOCK;FF',
'Explanation': 'Set transducer user tag'
}
},
'User Switch': {
'set_userswitch_on_off': {
'Command': '@{}SW!ON;FF',
'Response': '@xxxACKON;FF',
'Explanation': 'Enable / disable user switch'
}
}
}
error_responses = [
['NAK Code', 'Error', 'description'],
['8', 'Zero adjustment at too high pressure', '@253VAC!;FF'],
['9', 'Atmospheric adjustment at too low pressure', '@253ATM!7.60;FF'],
['160', 'Unrecognized message', '@253S%;FF'],
['169', 'Invalid argument', '@253EN1!of;FF'],
['172', 'Value out of range', '@253SP1!5.00E+9;FF'],
['175', 'Command/query character invalid', '@253FV!;FF'],
['180', 'Not in setup mode (locked)', '-'],
]
# xxx = Transducer communication address (001 to 253. Broadcast addresses: 254, 255)
broadcast_address_1 = 254 # 254 WILL cause any listening sensors to reply
broadcast_address_2 = 255 # 255 will NOT cause any listening sensors to reply
DEBUG = False
import serial
class Mks901P(object):
def __init__(self, com_port_name, baud=9600):
self.com_port_name = com_port_name
if DEBUG:
print('creating new MKS 901p object with baud of {}'.format(baud))
self.serial_port = serial.Serial(com_port_name, baudrate=baud, timeout=1)
#self.serial_port.read()
self.pressure_unit = None
@classmethod
def baud_rate(cls):
# return: None or ((str) sensor ID, (str) baud_rate)
from subprocess import STDOUT, check_output, TimeoutExpired
for baud in baud_supported:
print("attempting to ask MKS 901p for it's baudrate using baudrate of {}".format(baud))
cmd = [sys.executable, this_files_path, com_port, '--find_baud', '--baud={}'.format(baud)]
try:
output = check_output(cmd, stderr=STDOUT, timeout=1)
if output:
output = output.decode().split(',')
output = [o.strip("() '\n") for o in output]
print('sensor ({}) replied with baudrate of ({})'.format(output[0], output[1]))
return (output[0], output[1])
except TimeoutExpired:
pass
def get_pressure_unit(self, address=broadcast_address_1):
cmd = commands['Calibration and adjustment information']['get_pressure_unit']
expect = cmd['Response']
cmd = cmd['Command']
output = self.send_cmd(cmd, expect, address)
if output:
self.pressure_unit = output[1]
return self.pressure_unit
def get_pressure_combined_4_digit(self, address=broadcast_address_1, return_address=False):
cmd = commands['Pressure reading']['combined_4_digit']['Command']
expect = commands['Pressure reading']['combined_4_digit']['Response']
output = self.send_cmd(cmd, expect, address)
if output and not return_address:
return output[1]
return output
def send_cmd(self, cmd, expected_response, address):
cmd = cmd.format(address)
if not self.serial_port:
return('no connection')
self.serial_port.write(bytes(cmd.encode()))
raw_data = self.serial_port.read(len(expected_response))
data = raw_data.decode()
if 'ACK' in data:
addr = data[data.index('@')+len('@'):data.index('ACK')]
value = data[data.index('ACK')+len('ACK'):].split(';')[0]
return (addr,value)
else:
if DEBUG:
print('no ACK received from cmd')
return None
import os
import sys
import time
from ds18b20 import DS18B20
this_files_path = os.path.abspath(__file__)
if __name__ == '__main__':
import argparse
parser = argparse.ArgumentParser()
parser.add_argument("serial_port", help='the Windows COM port or path to a linux serial port')
parser.add_argument("--find_baud", help='tries to access the sensor over all supported baud rates, prints which is successful', action="store_true")
parser.add_argument("--baud", help='baud rate to connect with, defaults to 9600 (901p factory default)', type=int)
parser.add_argument("-unit", help='print pressure unit with each reading', action="store_true")
parser.add_argument("-pi_lcd", help='print pressure to RasPi LCD', action="store_true")
parser.add_argument("-sleep", help='amount to sleep between pressure readings, default 1 second', type=int)
args = parser.parse_args()
com_port = args.serial_port
if args.find_baud and not args.baud:
Mks901P.find_baud()
elif args.find_baud and args.baud:
if DEBUG:
print('setting up connection using baudrate of: {}'.format(args.baud))
m = Mks901P(com_port, args.baud)
cmd = commands['Communication information']['get_baud_rate']['Command']
expect = commands['Communication information']['get_baud_rate']['Response']
print(m.send_cmd(cmd, expect, broadcast_address_1))
else:
if args.baud:
m = Mks901P(com_port, args.baud)
else:
m = Mks901P(com_port)
unit = ''
sleep_time = 1
if args.sleep:
sleep_time = args.sleep
if args.unit:
unit = ' {}'.format(m.get_pressure_unit())
if args.pi_lcd:
import lcd
lcd.setup_gpio()
x = DS18B20()
count=x.device_count()
file_prefix = 'pressure_log_'
num_prev_files = len([item for item in os.listdir('.') if item.startswith(file_prefix)])
logfile = open(file_prefix+str(num_prev_files), 'w', buffering=128)
logfile.write(unit+'\n')
try:
while True:
pressure = '{}'.format(m.get_pressure_combined_4_digit())
pressure_float = float(pressure)
pressure_string = '{}{}'.format(pressure, unit)
temps = ' '.join([str(x.tempC(i)) for i in range(count)])
logfile.write('{} {}\n'.format(pressure, temps))
lcd.lcd_text(pressure_string, lcd.LCD_LINE_1)
lcd.lcd_text('{}'.format(temps), lcd.LCD_LINE_2)
time.sleep(sleep_time)
except KeyboardInterrupt:
pass
finally:
lcd.lcd_write(0x01, lcd.LCD_CMD)
import RPi.GPIO as GPIO
lcd.lcd_text("Reading stopped!", lcd.LCD_LINE_1)
GPIO.cleanup()
else:
while True:
print('{}{}'.format(m.get_pressure_combined_4_digit(), unit))
time.sleep(sleep_time)