Skip to content

Latest commit

 

History

History
121 lines (104 loc) · 7.32 KB

README.md

File metadata and controls

121 lines (104 loc) · 7.32 KB

ESPHome PowMr Hybrid Inverter

ESPHome config for various PowMr Hybrid Inverter models.

Compatibility

All models that are supported by the WIFI-VM device should work:

Tested models

  • POW-HVM2.4H-24V
  • POW-HVM10.2M

Connection

PowMr ESP32 connection diagram

ESP8266

This configuration can be used on the ESP8266, but you won't be able to use all the sensors due to the memory limitations of the ESP8266. You can use minimal set of sensors/selects, leaving only the ones you need. You can use "Heap size" sensor of Debug module to determine how much free memory left. Looks like minimum heap size, that ensures stability, is near 6Kb. Although I still strongly recommend using ESP32.

Usage

  1. Create new project subdirectory within your ESPHome configuration directory (let it be powmr-inverter, for example)
  2. Copy the contents of the src repo folder to a newly created project directory.
  3. Now, the main.yaml file must be located under <esphome_config>/powmr-inverter
  4. Create file powmr-inverter.yaml in the esphome config directory root and copy contents of example config
  5. Edit substitutions & customize powmr-inverter.yaml. You can add contents of common_system & common_sensors to this file or include them separately following the example.
  6. Flash firmware to your ESP32

PCB`s

There are 2 versions of PCB design available. Advanced version is more compact but needs SMD soldering skills, basic version uses 2.54 parts & modular approach.

PZEM module

In version 1.2, a PZEM module was added for measuring parameters of the input AC grid. If you do not wish to use it, comment out the include of the corresponding module in the main.yaml file.

Inverter card

For easy integration into Home Assistant, you can use the following snippet. It compiles all the essential inverter sensors and controls in a compact manner. The following custom plugins are required: sunsynk-power-flow-card, stack-in-card, tabbed-card, canary.

Inverter card page 1 screenshot Inverter card page 2 screenshot Inverter card page 3 screenshot

Optimize modbus communications

ESPHome reads sequential Modbus registers in one batch. If you have gaps in register addresses, you need to use the register_count parameter to skip N registers and continue the batch. Details in ESPHome docs.

You can debug your register ranges by setting the global log level to VERBOSE and muting all "noisy" components except the modbus_controller.

logger:
  level: VERBOSE
  logs:
    component: ERROR # Fix for issue #4717 "Component xxxxxx took a long time for an operation"
    modbus_controller: VERBOSE
    modbus_controller.text_sensor: WARN
    modbus_controller.sensor: WARN
    modbus_controller.binary_sensor: WARN
    modbus_controller.select: WARN

After this, the ranges map will be printed in the logs:

[15:55:14][C][modbus_controller:307]: ranges
[18:41:21][C][modbus_controller:307]: ranges
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x1196 count=37 skip_updates=0
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x11BC count=16 skip_updates=0
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x138A count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x138F count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x1391 count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x1399 count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x139A count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x139E count=1 skip_updates=2
[18:41:21][C][modbus_controller:310]:   Range type=3 start=0x13A0 count=1 skip_updates=2

In the example above, the sensor registers batches starts from 0x1196 & 0x11BC (one large batch causes data errors). Select registers starts from 0x138A. Using batches for selects triggers Modbus device set offline warning messages, so you need to read them separately.

You will see gaps in register ranges map. To calculate register_count, you need to convert HEX addresses to decimal and subtract them.

UART debugging

  • Uncomment debug section in modules/inverter.yaml or modules/pzem.yaml to enable the debug output of the UART component
      # debug:
      #   direction: BOTH
      #   dummy_receiver: false
    
  • Increase the log level to DEBUG or VERBOSE
    logger:
      level: WARN
    

Notes

References & thanks