From d9e9a729326c9fc3ce78ad58a1751bbbb333bd1b Mon Sep 17 00:00:00 2001 From: LKuemmel Date: Thu, 18 Apr 2024 08:02:54 +0200 Subject: [PATCH] build UI --- .../modules/legacy_smart_home/smarthomeconfig.php | 14 +++++++------- 1 file changed, 7 insertions(+), 7 deletions(-) diff --git a/web/settings/modules/legacy_smart_home/smarthomeconfig.php b/web/settings/modules/legacy_smart_home/smarthomeconfig.php index 325ced30ef..dab23786a3 100644 --- a/web/settings/modules/legacy_smart_home/smarthomeconfig.php +++ b/web/settings/modules/legacy_smart_home/smarthomeconfig.php @@ -117,18 +117,18 @@ Generisches MQTT modul
Wenn Einschaltbedingung erreicht (Beispiel hier mit Device 4)
- openWB/LegacySmartHome/set/Devices/4/ReqRelay = 1
- openWB/LegacySmartHome/set/Devices/4/Ueberschuss = in Watt
+ openWB/set/LegacySmartHome/Devices/4/ReqRelay = 1
+ openWB/set/LegacySmartHome/Devices/4/Ueberschuss = in Watt
Wenn Ausschaltbedingung erreicht
- openWB/LegacySmartHome/set/Devices/4/ReqRelay = 0
- openWB/LegacySmartHome/set/Devices/4/Ueberschuss = in Watt
+ openWB/set/LegacySmartHome/Devices/4/ReqRelay = 0
+ openWB/set/LegacySmartHome/Devices/4/Ueberschuss = in Watt
ReqRelay gibt den Status vom Gerät aus Sicht openWb an (1 = eingeschaltet, 0 = ausgeschaltet)
Bei der periodischen Abfrage wird die aktuelle Leistung
- openWB/LegacySmartHome/set/Devices/4/Aktpower = in Watt erwartet
+ openWB/set/LegacySmartHome/Devices/4/Aktpower = in Watt erwartet
und der aktuelle Zähler in Wattstunden wird hier erwartet
- openWB/LegacySmartHome/set/Devices/4/Powerc
+ openWB/set/LegacySmartHome/Devices/4/Powerc
wenn kein Zähler übergeben oder 0 übergeben wird, wird der Zähler selber gerechnet
- openWB/LegacySmartHome/set/Devices/4/Ueberschuss = in Watt
+ openWB/set/LegacySmartHome/Devices/4/Ueberschuss = in Watt
DAC angesteuert über Lan. Der anliegende Überschuss wird in eine Voltzahl zwischen 0.01V und 10.0V umgewandelt. Bezug wird als 0 Volt übertragen.