I started making an OTA module that uses the FOTA API (https://ai-thinker-open.github.io/GPRS_C_SDK_DOC/en/c-sdk/function-api/fota.html) to update the firmware from a server. I would try running this from a micropython code or, if it doesn't work, use native code to check for updates and upgrade firmware before starting to run Micropython code.
I started to make the module but couldn't go further because I can't generate the .pack file to test at all, even using the FOTA example. Maybe I will come back to this later, but if anyone wants to give it a try. Would be something like this.
static void processFotaUpgradeData(const unsigned char *data, int len)
{
if(len)
{
MEMBLOCK_Trace(1, (uint8_t*)data, (uint16_t)len, 16);
if(!API_FotaInit(len))
goto upgrade_failed;
if(API_FotaReceiveData((unsigned char*)data, (int)len) == 0);
}else{//error
goto upgrade_failed;
}
return;
upgrade_failed:
mp_printf(&mp_plat_print,"OTA upgrade failed");
API_FotaClean();
}
STATIC mp_obj_t modota_update(size_t n_args, const mp_obj_t *args) {
// ========================================
// Get update from server and upgrade firmware.
// Args:
// url (str): url from firmware server file on .pack format
// ========================================
if (n_args != 1) {
mp_raise_ValueError("Unexpected number of argument: 1 is required");
}
const char* c_url = mp_obj_str_get_str(args[0]);
if(API_FotaByServer((char*)c_url, processFotaUpgradeData) == 0)
mp_printf(&mp_plat_print,"Starting OTA update");
else
mp_printf(&mp_plat_print,"OTA update failed");
return mp_const_none;
}
STATIC MP_DEFINE_CONST_FUN_OBJ_1(modota_update_obj, modota_update);
STATIC const mp_map_elem_t mp_module_ota_globals_table[] = {
{ MP_OBJ_NEW_QSTR(MP_QSTR___name__), MP_OBJ_NEW_QSTR(MP_QSTR_ota) },
{ MP_OBJ_NEW_QSTR(MP_QSTR_update), (mp_obj_t)&modota_update_obj },
};
STATIC MP_DEFINE_CONST_DICT(mp_module_ota_globals, mp_module_ota_globals_table);
const mp_obj_module_t ota_module = {
.base = { &mp_type_module },
.globals = (mp_obj_dict_t*)&mp_module_ota_globals,
};
upgrade firmware before starting to run Micropython code.
This is probably too intrusive.
What I learned from docs is that you need to build specific incremental images to make it work. Should be quite straightforward otherwise. Lod files are just addresses and text.
I started making an OTA module that uses the FOTA API (https://ai-thinker-open.github.io/GPRS_C_SDK_DOC/en/c-sdk/function-api/fota.html) to update the firmware from a server. I would try running this from a micropython code or, if it doesn't work, use native code to check for updates and upgrade firmware before starting to run Micropython code.
I started to make the module but couldn't go further because I can't generate the .pack file to test at all, even using the FOTA example. Maybe I will come back to this later, but if anyone wants to give it a try. Would be something like this.
There are already ways to just update .py/.mpy files like this one (https://medium.com/@ronald.dehuysser/micropython-ota-updates-and-github-a-match-made-in-heaven-45fde670d4eb). OTA updating entire firmware with all modules/main freezed seems better in terms of security and also update the freezed modules and bugs from the platform.