Pyrevit 4.8.16.24121 not working via SCCM #2304
Comments
Please have a look at #1642 (comment) |
Do we have any documentation which we can refer for the installation via SCCM |
Not strictly SCCM related, but this should help https://pyrevitlabs.notion.site/pyRevit-For-Teams-ddc6c312d6f6488691eed2ec7704fd97 |
My experience with the SCCM installer is to script this sequence: $ErrorActionPreference = "Continue"
Remove-Item -Path "C:\Users\*\AppData\Roaming\pyRevit\pyRevit_config.ini"
Remove-Item -Path "C:\ProgramData\pyRevit\pyRevit_config.ini"
Remove-Item -Path "C:\Windows\System32\config\systemprofile\AppData\Roaming\pyRevit\pyRevit_config.ini"
Remove-Item -Path "C:\Users\*\AppData\Roaming\pyRevit" -Recurse
Remove-Item -Path "C:\Windows\System32\config\systemprofile\AppData\Roaming\pyRevit" -Recurse
Remove-Item -Path "C:\ProgramData\Autodesk\Revit\Addins\*\pyRevit.addin"
Remove-Item -Path "C:\WINDOWS\TEMP\master\pyRevit-master" -Recurse
Remove-Item -Path "C:\pyRevit" -Recurse |
Thanks @GHiarsixty for the added info! this would make a good addition in our "knowledge base", do you think you can make it into a tutorial in the forum to explain all the steps in detail? regarding the code snippet, I believe you can simplify it like this $ErrorActionPreference = "Continue"
Remove-Item -Path "C:\ProgramData\pyRevit\pyRevit_config.ini"
Remove-Item -Path "C:\Users\*\AppData\Roaming\pyRevit" -Recurse
Remove-Item -Path "C:\Windows\System32\config\systemprofile\AppData\Roaming\pyRevit" -Recurse
Remove-Item -Path "C:\ProgramData\Autodesk\Revit\Addins\*\pyRevit.addin" since you're recursing the entire directories, you don't need to remove the config file first. |
Installation of Pyrevit 4.8.16.24121 went well, but unable to view the plugin in Revit.
If I manually install the application , I can see the plugin in Revit.
So just want to confirm whether this plugin will support in SCCM or not.