One sample of each list on the Kaifa MA304H3E meter
(Samples are captured from my meter and the breakdown and values are from . Please note that units and/or data types in this document doesn't seem to be right. E.g. my total meter reading is 403 kWh, not the tenfold. Hopefully, the current is also closer to 1A than 1000A in each wire)
For the data parts, I have found they follow a pattern where the first byte dictates the data type and size:
02 - one byte following
06 - long (4 bytes / 32 bits)
09 - string, first byte is length
List #1 (0x01) (time is 1506275242) consumption is 601 Watts
Data
Explaination
Value
E6 E7 00 0F 40 00 00 00
Uknown
09 0C 07 E1 09 18 07 11 2F 16 FF 80 00 00
Date and time
2017-09-24 17:47:22
02 01
List (02) of 1 elements (01) following
0x01 = one element
06 00 00 02 59
Active power+ (Q1+Q4)
0.601 kW
List #2 (0x0D) (time is 1506275240)
Data
Explaination
Value
E6 E7 00 0F 40 00 00 00
Unknown
09 0C 07 E1 09 18 07 11 2F 14 FF 80 00 00
Date and time
2017-09-24 17:47:20 (FF=hundreds not available, 8000=deviation, 00=status)