Notifications
You must be signed in to change notification settings - Fork 4
/
packet_test.go
130 lines (117 loc) · 3.25 KB
/
packet_test.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
// Copyright 2019 Sergey Soldatov. All rights reserved.
// This software may be modified and distributed under the terms
// of the Apache license. See the LICENSE file for details.
package modbus
import (
"testing"
)
type testCrc16Checkpair struct {
TypeProtocol ModbusTypeProtocol
data []byte
res bool
}
var testsCrc16Check = []testCrc16Checkpair{
{ModbusRTUviaTCP, []byte{0x1, 0x3, 0x0, 0x0, 0x0, 0xA, 0xCD, 0xC5}, true},
}
func TestModbusPacket_Crc16Check(t *testing.T) {
mp := new(ModbusPacket)
for _, pair := range testsCrc16Check {
mp.Init(pair.TypeProtocol)
copy(mp.PDU, pair.data)
mp.Length = len(pair.data)
res := mp.IsCrcGood()
if res != pair.res {
t.Error(
"For", pair.data,
"expected", pair.res,
"got", res,
)
}
}
}
func TestModbusPacket_GetFunctionCode(t *testing.T) {
test_data := []byte{0x1, 0x3, 0x0, 0x0, 0x0, 0xA, 0xCD, 0xC5}
mp := &ModbusPacket{}
mp.Init(ModbusRTUviaTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res := mp.GetFunctionCode()
if res != ModbusFunctionCode(0x3) {
t.Error("Expected", byte(0x3), "got", res)
}
test_data = []byte{0x0, 0x0, 0x0, 0x0, 0x0, 0x0, 0x1, 0x3, 0x0, 0x0, 0x0, 0xA}
mp.Init(ModbusTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res = mp.GetFunctionCode()
if res != ModbusFunctionCode(0x3) {
t.Error("Expected", byte(0x3), "got", res)
}
}
func TestModbusPacket_GetFC(t *testing.T) {
test_data := []byte{0x1, 0x3, 0x0, 0x0, 0x0, 0xA, 0xCD, 0xC5}
mp := &ModbusPacket{}
mp.Init(ModbusRTUviaTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res := mp.GetFunctionCode()
if res != FcReadHoldingRegisters {
t.Error("Expected", FcReadHoldingRegisters, "got", res)
}
test_data = []byte{0x0, 0x0, 0x0, 0x0, 0x0, 0x0, 0x1, 0x3, 0x0, 0x0, 0x0, 0xA}
mp = &ModbusPacket{}
mp.Init(ModbusTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res = mp.GetFunctionCode()
if res != FcReadHoldingRegisters {
t.Error("Expected", FcReadHoldingRegisters, "got", res)
}
}
func TestModbusPacket_GetCrc(t *testing.T) {
test_data := []byte{0x1, 0x3, 0x0, 0x0, 0x0, 0xA, 0xCD, 0xC5}
mp := &ModbusPacket{}
mp.Init(ModbusRTUviaTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res := mp.GetCrc()
if res != uint16(0xCDC5) {
t.Error("Expected", uint16(0xCDC5), "got", res)
}
test_data = []byte{0x0, 0x0, 0x0, 0x0, 0x0, 0x0, 0x1, 0x3, 0x0, 0x0, 0x0, 0xA}
mp = &ModbusPacket{}
mp.Init(ModbusTCP)
copy(mp.PDU, test_data)
mp.Length = len(test_data)
res = mp.GetCrc()
if res != uint16(0x0) {
t.Error("Expected", uint16(0x0), "got", res)
}
}
type testbuildPacketpair struct {
isReq bool
TypeProtocol ModbusTypeProtocol
dev_id byte
fc ModbusFunctionCode
par1, par2 uint16
PDU []byte
}
var testsbuildPacket = []testbuildPacketpair{
{true, ModbusRTUviaTCP, 1, FcReadHoldingRegisters, 0x0, 0xA, []byte{0x1, 0x3, 0x0, 0x0, 0x0, 0xA, 0xC5, 0xCD}},
}
func TestModbusPacket_buildPDU(t *testing.T) {
for _, pair := range testsbuildPacket {
mp := &ModbusPacket{}
mp.Init(pair.TypeProtocol)
mp.buildPDU(pair.dev_id, pair.fc, pair.par1, pair.par2)
for i, v := range mp.PDU[:mp.GetPDULength()] {
if v != pair.PDU[i] {
t.Error(
"For", pair,
"expected", pair.PDU[i],
"got", v,
)
}
}
}
}