BOM C9,C10 is missleading #5

Open
PierreKircher opened this issue May 11, 2017 · 1 comment
Open

BOM C9,C10 is missleading #5

PierreKircher opened this issue May 11, 2017 · 1 comment
Labels

Comments

@PierreKircher
Copy link

PierreKircher commented May 11, 2017

https://puu.sh/vMOZJ/848d226294.png

Values says 6 pico farat
but description says 15 PF
with a tollerance of 0.5% id like to know what to use ..

i dont want to reflow both 0402 cap's if i mess that one up - thank you

@PierreKircher PierreKircher changed the title BOM C9 is missleading BOM C9,C10 is missleading May 11, 2017
@santaimpersonator
Copy link

I know it has been a while and it might have been updated, but I just pulled the schematic (eagle file) and the values for C9 and C10 seem to match the labeling at 6pF.

Are you possibly referring to C13 and C14, which are at 15pF?