import logging
import sys
import time
from pathlib import Path
from umrx_app_v3.shuttle_board.bma400.bma400_shuttle import BMA400Shuttle
def setup_logging(level: int = logging.DEBUG) -> logging.Logger:
logger = logging.getLogger()
logger.setLevel(level)
stdout_handler = logging.StreamHandler(sys.stdout)
log_format = "(%(asctime)s) [%(levelname)-8s] %(filename)s:%(lineno)d: %(message)s"
log_formatter = logging.Formatter(log_format)
stdout_handler.setFormatter(log_formatter)
file_handler = logging.FileHandler(f"{Path(__file__).parent / Path(__file__).stem}.log", mode="w")
file_handler.setFormatter(log_formatter)
logger.addHandler(stdout_handler)
logger.addHandler(file_handler)
return logger
if __name__ == "__main__":
logger = setup_logging()
shuttle = BMA400Shuttle.on_hardware_v3_rev1()
shuttle.initialize()
shuttle.check_connected_hw()
shuttle.configure_spi()
_ = shuttle.board.read_spi(shuttle.CS, 0, 1) # dummy read is required, do not delete
logger.info(f"chip_id=0x{shuttle.sensor.chip_id:02X}")
logger.info(f"err_reg=0x{shuttle.sensor.err_reg:02X}")
logger.info(f"status=0x{shuttle.sensor.status:02X}")
logger.info(f"acceleration={shuttle.sensor.acc_data}")
logger.info(f"sensor_time={shuttle.sensor.sensor_time}")
shuttle.switch_on_accel()
time.sleep(0.1)
logger.info(f"acceleration={shuttle.sensor.acc_data}")
logger.info(f"sensor_time={shuttle.sensor.sensor_time}")