xbee-promise

An XBee promise-based API

NPM version Travis CI Build Status

The xbee-promise Node.js module wraps the xbee-api module with a promise-based API for ZigBee modules. It may work with older 802.15.4 modules, but it has not been tested with them. Currently it facilitates local commands, remote commands, and remote transmissions. For remote commands and transmissions, either a address or node ID may be provided, with automatic lookup and aching done for the node ID.

xbee-promise relies on serialport for serial communications.

Usage

First, you will need to install the xbee-promise module (i.e. npm install xbee-promise).

Initialization

To create a connection to your module, you will need to know the serial port that it is connected to. On Windows, this typically has the form COMx, where x is a number. On unix and OS X machines, this will typically be /dev/tty???, where ??? can be anything from USB0 to .usbserial-A4013E5P. In addition, you will need to make sure that the module connected to your machine is in API mode and that you know the baudrate it is set to. By default, the baudrate is 57600 when API mode is used. In addition, you will need to know if you are using a ZigBee module, a ZNet module or a 802.15.4 module. These are sometimes referred to as series 2 for ZigBee or series 1 for 802.15.4. (Currently there are no differences in how this library works between the ZigBee and ZNet modules. Older series 2 modules have ZNet firmware and can typically be upgraded to ZigBee firmware.) Once these details are known, you can initialize xbee-promise:

var xbeePromise = require('xbee-promise');

var xbee = xbeePromise({
    serialport: '/dev/ttyUSB0',
    serialPortOptions: {
        baudrate: 57600
    },
    module: "ZigBee"
});

Note: if you are using API mode 2, you must specify that with the api_mode parameter (api_mode: 2). You can give any options known by serialport inside serialportOptions (other than parser as it is used and set by xbee-promise). To see what the library is doing (during lookups, etc), you can add the debug flag (debug: true). Finally, you can set the default timeout for all commands with defaultTimeout. The default is 5000 milliseconds.

Local commands

Local commands may be performed using the localCommand fuction. They can be query commands (no parameters) or set commands (with parameters).

xbee.localCommand({
    // ATMY
    // get my 16 bit address
    command: "MY"
}).then(function (response) {
    // response will be an array of two bytes, e.g. [ 23, 167 ]
    console.log("ATMY response:\n", response);
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});
xbee.localCommand({
    // ATD1 5
    // turn digital output 1 on
    command: "D1",
    commandParameter: [ 5 ]
}).then(function (response) {
    // response will be [ 0 ] from the response frame
    console.log("Success!");
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});

Remote commands

Remote commands may be performed using the remoteCommand fuction. They are similar to local commands, but must have either a destination64 64 bit address, a destination16 16 bit address or a destinationId node ID to indicate the target of the command. destinationId is not supported by 802.15.4 modules.

xbee.remoteCommand({
    // ATD0
    // get the status of digital pin 0
    command: "D0",
    // this ID must be set on the target node with ATNI
    destinationId: "FUNNODE"
}).then(function (response) {
    // response will be a single value in an array, e.g. [ 1 ]
    console.log("ATD0 response from FUNNODE:\n", response);
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});
xbee.remoteCommand({
    // ATD3
    // get the status of digital pin 3
    command: "D3",
    // destination addresses can be in hexidecimal or byte arrays
    destination16: [ 0xa9, 0x78 ]
}).then(function (response) {
    // response will be a single value in an array, e.g. [ 1 ]
    console.log("ATD3 response from FUNNODE:\n", response);
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});
xbee.remoteCommand({
    // ATD1 4
    // Turn digital output 1 off
    command: "D1",
    commandParameter: [ 4 ],
    // destination addresses can be in hexidecimal or byte arrays
    // serial number from the bottom of the module (or combination of ATSH and ATSL)
    destination64: '0013a20040a099a1'
}).then(function (response) {
    // response will be [ 0 ] from the response frame
    console.log("Success!");
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});

Remote transmission

Remote commands may be performed using the remoteTransmit fuction. The destination is set in the same manner as for remote commands. The text to send is given with the data parameter.

xbee.remoteTransmit({
    // this ID must be set on the target node with ATNI
    destinationId: "FUNNODE",
    data: "I'm sending you text, FUNNODE!"
}).then(function (response) {
    // response will be true for a successful transmision
    console.log("Text sent to FUNNODE!");
}).catch(function (e) {
    console.log("Command failed:\n", e);
}).fin(function () {
    xbee.close();
});

Some more examples can be found in the repository.

Future work

This library is in maintenance mode. Future development is aimed at the xbee-rx library. Pull requests are welcomed, however.