The water vapor continuum in the microwave through far-infrared was modified (E. Mlawer, V. Payne, J. Mascio, D. Turner). The modifications will be detailed in Payne _et al._ (2021).
Revised self and foreign continuum coefficients in the microwave were derived based on DOE ARM MWR measurements using an approach similar to that in Payne _et al._ (2010). The temperature dependence of the self continuum in the microwave was modified based on Katkov _et al._ (1995), Tretyakov _et al._ (2016) and the ARM MWR analysis.
The self continuum in the far-infrared was revised based on Odintsova _et al._ (2020), and the temperature dependence of the self continuum is based on Odintsova _et al._ (2020) and Burch and Grynvak (1979). Beyond the far-IR (up to 800 cm-1), the self temperature dependence was revised based on Burch and Alt (1984) and Burch and Grynvak (1979).
A bugfix in the oxygen A-band continuum module was implemented (E. Mlawer, J. Mascio, E. Magee).